{"title":"Protection Relays by Product Line","description":"","products":[{"product_id":"rel52123-easergy-p3f30-3ct-2io-ringlug-4vt-6di-10do-2obio-5arc-rs485-rj45","title":"Easergy P3F30 3CT 2Io ringlug 4VT 6DI 10DO 2OBIO 5ARC RS485 RJ45 ANSI","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring Function: trip circuit supervision 74 || circuit breaker monitoring || relay self-monitoring\u003c\/li\u003e\n\u003cli\u003eAnalogue Output Number: 0\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Number: 0\u003c\/li\u003e\n\u003cli\u003eInput Type: 3 1\/5 A CT phase current || 1 5\/1 A CT residual current || 1 1\/0.2 A CT residual current || 4 100 V\/110 V VT voltage\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: screw removable (digital input\/output) || ring lugs fixed (current transformer) || pin removable (voltage transformer)\u003c\/li\u003e\n\u003cli\u003eNetwork And Machine Diagnosis Type: event recording || disturbance recording || tripping context\u003c\/li\u003e\n\u003cli\u003eDevice Mounting: flush\u003c\/li\u003e\n\u003cli\u003eControl Type: switchgear control and monitoring || programmable switchgear interlocking || local control on single-line diagram || local control with I\/O keys || local\/remote control || 2 function keys || mobile application with Easergy SmartApp || web-server\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 10 DO || 1 watchdog\u003c\/li\u003e\n\u003cli\u003eDigital Input Number: 6.0\u003c\/li\u003e\n\u003cli\u003eSetting: 4\u003c\/li\u003e\n\u003cli\u003eProtection Type: fault locator 21FL || synchro-check 25 || undervoltage 27 || directional active underpower 37P || broken conductor 46BC || thermal overload protection 49 || earth fault overcurrent 50N\/51N || phase overcurrent 50\/51 || breaker failure 50BF || switch ON to fault (SOTF) || capacitor bank unbalance 51C || voltage-restrained overcurrent 51V || capacitor overvoltage 59C || overvoltage 59 || earth fault overvoltage 59N || directional phase overcurrent 67 || directional earth fault 67N || transient earth fault 67NI || H2 detection 68H2 || H5 detection 68H5 || recloser 79 || underfrequency 81\/81N || rate of change of frequency 81R || lockout relay 86 || programmable stages 99 || programmable curve || cold load pick-up\u003c\/li\u003e\n\u003cli\u003eRelay Application: feeder\u003c\/li\u003e\n\u003cli\u003eIntegrated Connection Type: front USB port 1 || rear RJ45 1 || rear RS485 1\u003c\/li\u003e\n\u003cli\u003eCybersecurity: password protection || port hardening\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: IEC 61850 ed. 1 || IEC 61850 ed. 2 || IEC 60870-5-101 || DNP3 TCP || Modbus TCP || EtherNet\/IP || IEC 60870-5-103 || DNP3 || Modbus RTU || DeviceNet || SPAbus\u003c\/li\u003e\n\u003cli\u003eNumber Of Sensors: 0 temperature || 0 arc\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: protection relay\u003c\/li\u003e\n\u003cli\u003eSwitchgear Diagnosis Type: CT\/VT supervision || trip circuit supervision TCS\u003c\/li\u003e\n\u003cli\u003eArc Flash Protection: yes\u003c\/li\u003e\n\u003cli\u003eSingle Line Diagram: 3 controlled + 5 displayed\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current 3-phase || current zero sequence || current positive sequence || current negative sequence || current ratio of negative and positive || voltage phase to earth || voltage phase to phase || voltage zero sequence || voltage positive sequence || voltage negative sequence || voltage ratio of negative and positive || short circuit fault reactance || fault location current || earth fault reactance || frequency || active power || RMS active power || reactive power || RMS reactive power || apparent power || RMS apparent power || active energy || reactive energy || cos φ || tan φ || power angle || power factor || voltage phasor diagram view || current phasor diagram view || current 2nd, 15th harmonics with THD || voltage 2nd, 15th harmonics with THD || condition monitoring CB wear || voltage interruption\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: P3F30-DCGAD-DA1FA-BAAAB\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 24...48 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNumber Of Key: 2 customizable\u003c\/li\u003e\n\u003cli\u003eOperating Threshold: 24 V AC\/DC\u003c\/li\u003e\n\u003cli\u003eTime Synchronisation Protocol: SNTP\u003c\/li\u003e\n\u003cli\u003eWidth: 270 mm\u003c\/li\u003e\n\u003cli\u003eHeight: 176 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: and LCD 128 x 128 pixels with single line diagram || and LCD 128 x 128 pixels with ANSI symbols\u003c\/li\u003e\n\u003cli\u003eNet Weight: 4.2 kg maximum\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: 2 LEDs || 16 LEDs programmable\u003c\/li\u003e\n\u003cli\u003eDepth: 230 mm\u003c\/li\u003e\n\u003cli\u003eWeb Server: embedded HTTP server\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eElectromagnetic Compatibility: emission tests IEC\/EN 60255-26 ed. 3 || emission tests class A CISPR 11 || emission tests class A CISPR 22 || EMC immunity IEC\/EN 60255-26 ed. 3 || EMC immunity EN\/IEC 61000-4-18 || EMC immunity IEC 60255-22-1 || EMC immunity level 4 EN\/IEC 61000-4-2 || EMC immunity IEC 60255-22-2 || EMC immunity level 3 EN\/IEC 61000-4-3 || EMC immunity IEC 60255-22-3 || EMC immunity level 4 EN\/IEC 61000-4-4 || EMC immunity IEC 60255-22-4 || EMC immunity level 3 EN\/IEC 61000-4-5 || EMC immunity IEC 60255-22-5 || EMC immunity level 3 EN\/IEC 61000-4-6 || EMC immunity IEC 60255-22-6 || EMC immunity EN\/IEC 61000-4-8 || EMC immunity level 5 EN\/IEC 61000-4-9 || EMC immunity EN\/IEC 61000-4-29 || EMC immunity EN\/IEC 61000-4-11 || EMC immunity EN\/IEC 61000-4-17 || EMC immunity IEC 60255-27 || EMC immunity class III IEC 60255-5 || EMC immunity EN\/IEC 60255-1\u003c\/li\u003e\n\u003cli\u003eMechanical Robustness: vibrations class II) IEC 60255-21-1 || vibrationsFc IEC 60068-2-6 || shocks class II) IEC 60255-21-2 || shocksEa IEC 60068-2-27 || seismic tests method A class II) IEC 60255-21-3\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 %, without condensation\u003c\/li\u003e\n\u003cli\u003eProtective Treatment: conformal coating\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -40-65 °C\u003c\/li\u003e\n\u003cli\u003eEnvironmental Characteristic: exposure to dry heat Bd EN\/IEC 60068-2-2 || exposure to cold Ad EN\/IEC 60068-2-1 || exposure to damp heat in service Db EN\/IEC 60068-2-30 || exposure to damp heat in service Cab EN\/IEC 60068-2-78\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 6561.68 ft (2000 m)\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: IP54 conforming to IEC 60529\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e0c23ae227e8dfa9439d6032af2d37e393f40e1.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/80265de0075a3cc11a75b3853d1a63bca68d5d51.pdf\" target=\"_blank\"\u003eEasergy P3L30 User Guide - P3L30_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c94177e5f9691d30cfb328401d2ca08299d575f7.pdf\" target=\"_blank\"\u003eEasergy P3M30 and P3M32 User Guide - P3M30_32_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b4871d34d72c88b352d5a0d5ebe1fbb3e6216960.pdf\" target=\"_blank\"\u003eEasergy P3F30 - P3F30_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8cdae4f25cb97a4198e9ba796ff5a15bc9cd3474.pdf\" target=\"_blank\"\u003eEasergy P3T32 - P3T32_en_M_K006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a48dc51f852c578c3abbd8ac8a0faf59ae5a264.pdf\" target=\"_blank\"\u003eEasergy P3G30 and P3G32 User Guide - P3G30_32_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003ch4\u003eApplication Notes\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0ff6459f9bb78de952326864964e6e9da65e6d88.zip\" target=\"_blank\"\u003eEnglish - P3Ux_dimensional_DWG.zip\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/19d65855cf19cf7b9340731694b0a45ce159b66e.pdf\" target=\"_blank\"\u003eEasergy P3 Advanced - Quick Start guide - P3X_en_QS_07_IEC_web (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/45caa67a5ab8ac3a74976bc2d7f59965439fb3f3.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3G32_v1 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a89219d333cd8e673743cfb616d2763c0a23f82.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M32_motor_connection (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47adb3e32c9fe9cb4a43c93f0c5bdb0a2031b21b.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M32_motor_connection (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e1c82fc51cae22acb619f49f8691159bdfb37c5d.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x3x_connection_3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6c463c3ab9b22939f9aa90b03beeb1413d45bebd.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M30_3LN_Uo_connection (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3742ab17f0dccedc962961ca47880bd3fee64d9e.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M30_3LN_Uo_connection (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0f8f00126a28bbb90bc0d7febdc59325df2d790f.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3G32_v1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fc1364ec461148fff0b26b21b4a64588ff863e23.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3T32_connection_v1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/689e9054befa6381dc7888776cd5e5229b7e69bc.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x30_connection_3 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/eadf9804c998f83b3b9d6a4ead681aaeb94284c5.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x3x_connection_3 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/64701dd265704d066fb31db964bf361cc4eee37a.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x30_connection_3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a54f0637bef0445184d9c3e4e4c7029e63ad347f.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3x3x_Capbank (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a41453394d007d103e8c59d7260dbc68c4186502.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3x3x_Capbank (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/feac83b0d2b75d503c9484e475155fb7255e0217.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3T32_connection_v1 (dwg)\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d7302fd9c9cb5f5d7a12e0ec31d74658f18bd5cf.pdf\" target=\"_blank\"\u003eEnglish - 18-2173_Rev1_DNVGL_SchneiderElectric_P3U30_P3F30_P3G30_P3G32_P3L30_P3M30... (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46063115567408,"sku":"REL52123","price":3079.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/dbdd54f699590a45f9ba64e62cb7bd5526fd320b-large.png?v=1691422825"},{"product_id":"rel52055-easergy-p3u-3ct-1io-ringlug-4vt-16di-8do-48-230v-di110v-rs485","title":"Easergy P3U 3CT 1Io ringlug 4VT 16DI 8DO 48-230V DI110V RS485 ANSI","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring Function: trip circuit supervision 74 || circuit breaker monitoring || relay self-monitoring\u003c\/li\u003e\n\u003cli\u003eAnalogue Output Number: 0\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Number: 0\u003c\/li\u003e\n\u003cli\u003eInput Type: 3 1\/5 A CT phase current || 1 1\/5 A CT residual current || 4 100 V\/110 V VT voltage\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: screw removable (digital input\/output) || ring lugs removable (current transformer) || pin removable (voltage transformer)\u003c\/li\u003e\n\u003cli\u003eNetwork And Machine Diagnosis Type: event recording || disturbance recording || tripping context\u003c\/li\u003e\n\u003cli\u003eDevice Mounting: flush\u003c\/li\u003e\n\u003cli\u003eControl Type: switchgear control and monitoring || programmable switchgear interlocking || local control on single-line diagram || local control with I\/O keys || local\/remote control || 2 function keys || mobile application with Easergy SmartApp || web-server\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 8 DO || 1 watchdog\u003c\/li\u003e\n\u003cli\u003eDigital Input Number: 16.0\u003c\/li\u003e\n\u003cli\u003eSetting: 4\u003c\/li\u003e\n\u003cli\u003eProtection Type: phase overcurrent 50\/51 || directional phase overcurrent 67 || earth fault overcurrent 50N\/51N || directional earth fault 67N || transient earth fault 67NI || capacitor bank unbalance 51C || broken conductor 46 I2\/I1 || cold load pick-up || H2 detection 68H2 || H5 detection 68H5 || breaker failure 50BF || switch ON to fault (SOTF) || directional active underpower 37P || fault locator 21FL || recloser 79 || phase undercurrent 37 || excessive starting time, locked rotor 48\/51LR || motor restart inhibition 66 || capacitor overvoltage 59C || negative sequence overcurrent 46 || overvoltage 59 || undervoltage 27 || positive sequence undervoltage 27P || earth fault overvoltage 59N || underfrequency 81\/81N || rate of change of frequency 81R || synchro-check 25 || lockout relay 86 || CT supervision 60 || VT supervision 60 || programmable stages 99 || programmable curve\u003c\/li\u003e\n\u003cli\u003eRelay Application: universal\u003c\/li\u003e\n\u003cli\u003eIntegrated Connection Type: front USB port 1 || rear RS485 1\u003c\/li\u003e\n\u003cli\u003eCybersecurity: password protection || port hardening\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: IEC 60870-5-101 || IEC 60870-5-103 || DNP3 || Modbus RTU || DeviceNet || SPAbus\u003c\/li\u003e\n\u003cli\u003eNumber Of Sensors: 0 temperature || 0 arc\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: protection relay\u003c\/li\u003e\n\u003cli\u003eSwitchgear Diagnosis Type: CT supervision || trip circuit supervision TCS\u003c\/li\u003e\n\u003cli\u003eArc Flash Protection: no\u003c\/li\u003e\n\u003cli\u003eSingle Line Diagram: 4 controlled + 8 displayed\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current 3-phase || current zero sequence || current positive sequence || current negative sequence || current ratio of negative and positive || voltage phase to earth || voltage phase to phase || voltage zero sequence || voltage positive sequence || voltage negative sequence || voltage ratio of negative and positive || short circuit fault reactance || fault location current || earth fault reactance || frequency || active power || RMS active power || reactive power || RMS reactive power || apparent power || RMS apparent power || active energy || reactive energy || cos φ || tan φ || power angle || power factor || voltage phasor diagram view || current phasor diagram view || current 2nd, 15th harmonics with THD || voltage 2nd, 15th harmonics with THD || condition monitoring CB wear || voltage interruption\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: P3U30-6AAA2BBAB\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 48...230 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNumber Of Key: 2 customizable\u003c\/li\u003e\n\u003cli\u003eOperating Threshold: 110 V AC\/DC\u003c\/li\u003e\n\u003cli\u003eWidth: 170 mm\u003c\/li\u003e\n\u003cli\u003eHeight: 169.5 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: and LCD 128 x 64 pixels with single line diagram || and LCD 128 x 64 pixels with ANSI symbols\u003c\/li\u003e\n\u003cli\u003eNet Weight: 2.5 kg maximum\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: 4 LEDs || 8 LEDs programmable\u003c\/li\u003e\n\u003cli\u003eDepth: 205 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eElectromagnetic Compatibility: emission tests IEC\/EN 60255-26 ed. 3 || emission tests class A CISPR 11 || emission tests class A CISPR 22 || EMC immunity IEC\/EN 60255-26 ed. 3 || EMC immunity EN\/IEC 61000-4-18 || EMC immunity IEC 60255-22-1 || EMC immunity level 4 EN\/IEC 61000-4-2 || EMC immunity IEC 60255-22-2 || EMC immunity level 3 EN\/IEC 61000-4-3 || EMC immunity IEC 60255-22-3 || EMC immunity level 4 EN\/IEC 61000-4-4 || EMC immunity IEC 60255-22-4 || EMC immunity level 3 EN\/IEC 61000-4-5 || EMC immunity IEC 60255-22-5 || EMC immunity level 3 EN\/IEC 61000-4-6 || EMC immunity IEC 60255-22-6 || EMC immunity EN\/IEC 61000-4-8 || EMC immunity level 5 EN\/IEC 61000-4-9 || EMC immunity EN\/IEC 61000-4-29 || EMC immunity EN\/IEC 61000-4-11 || EMC immunity EN\/IEC 61000-4-17 || EMC immunity IEC 60255-27 || EMC immunity class III IEC 60255-5 || EMC immunity EN\/IEC 60255-1\u003c\/li\u003e\n\u003cli\u003eMechanical Robustness: vibrations class II) IEC 60255-21-1 || vibrationsFc IEC 60068-2-6 || shocks class II) IEC 60255-21-2 || shocksEa IEC 60068-2-27 || seismic tests method A class II) IEC 60255-21-3\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 %, without condensation\u003c\/li\u003e\n\u003cli\u003eProtective Treatment: conformal coating\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -40-65 °C\u003c\/li\u003e\n\u003cli\u003eEnvironmental Characteristic: exposure to dry heat Bd EN\/IEC 60068-2-2 || exposure to cold Ad EN\/IEC 60068-2-1 || exposure to damp heat in service Db EN\/IEC 60068-2-30 || exposure to damp heat in service Cab EN\/IEC 60068-2-78\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 6561.68 ft (2000 m)\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: IP54 conforming to IEC 60529\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ec1345c5bf8b777b6078839c0890db69f715b3fa.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a2c8c7c9e9c2787423b995cd1a8e12f914d90471.pdf\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - P3_P3TDS17006_en_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38c1efaee50d52ddfe104831176050463a0170d7.zip\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - VVPA3CG_EN_M_D004 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/114fc7a1cc6108829135f7e6dbd50c59281a35c2.pdf\" target=\"_blank\"\u003eRTD I\/O unit manual - VVIO12A_EN_M_D001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fe15d0cfb54a548fe86b90f47e09cf94f48d0d9e.zip\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - VVSE2_EN_M_B007 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3901d75d75124610f0e011798db32c45fc119bd8.pdf\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - VVIO12A_EN_M_D002_print (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b3f738678c81755b9daa2b009245559efd15a95a.pdf\" target=\"_blank\"\u003eUser Guide Easergy P3Ux - P3U_en_M_K006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0086ace2f95595ae728f52e2075135ccb8c97c94.pdf\" target=\"_blank\"\u003eProfibus adapter - VVPA3CG_EN_M_C004 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/17dc7ff5bd41441df5d454046bfb8b344f2b7a5f.pdf\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - eSetup+Easergy+Pro+Setting+Tool+Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3b68f26cf951a7e327bd10ca83840d2985f5bed0.pdf\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - VVSE1_EN_M_B007 (pdf)\u003c\/a\u003e\u003ch4\u003eApplication Notes\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0ff6459f9bb78de952326864964e6e9da65e6d88.zip\" target=\"_blank\"\u003eEnglish - P3Ux_dimensional_DWG.zip\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/70b557636039bed0b3aa52979141a2ae658f0d20.pdf\" target=\"_blank\"\u003ePowerLogic™ Easergy P3 Catalog - P3_NRJCAT17764EN_v21 (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a89219d333cd8e673743cfb616d2763c0a23f82.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M32_motor_connection (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/eadf9804c998f83b3b9d6a4ead681aaeb94284c5.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x3x_connection_3 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fc1364ec461148fff0b26b21b4a64588ff863e23.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3T32_connection_v1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a41453394d007d103e8c59d7260dbc68c4186502.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3x3x_Capbank (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/64701dd265704d066fb31db964bf361cc4eee37a.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x30_connection_3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0f8f00126a28bbb90bc0d7febdc59325df2d790f.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3G32_v1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3742ab17f0dccedc962961ca47880bd3fee64d9e.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M30_3LN_Uo_connection (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6c463c3ab9b22939f9aa90b03beeb1413d45bebd.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M30_3LN_Uo_connection (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/689e9054befa6381dc7888776cd5e5229b7e69bc.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x30_connection_3 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e1c82fc51cae22acb619f49f8691159bdfb37c5d.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x3x_connection_3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/45caa67a5ab8ac3a74976bc2d7f59965439fb3f3.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3G32_v1 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/feac83b0d2b75d503c9484e475155fb7255e0217.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3T32_connection_v1 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a54f0637bef0445184d9c3e4e4c7029e63ad347f.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3x3x_Capbank (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47adb3e32c9fe9cb4a43c93f0c5bdb0a2031b21b.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M32_motor_connection (dwg)\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d7302fd9c9cb5f5d7a12e0ec31d74658f18bd5cf.pdf\" target=\"_blank\"\u003eEnglish - 18-2173_Rev1_DNVGL_SchneiderElectric_P3U30_P3F30_P3G30_P3G32_P3L30_P3M30... (pdf)\u003c\/a\u003e\u003ch4\u003eQuick start guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fe11d31e2be45ee29a1733b66095036bc0938a4f.pdf\" target=\"_blank\"\u003eEasergy P3 - Universal Relays P3U10, P3U20 and P3U30 - Quick Start guide - P3U_en_QS_07_IEC_web (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46063280849200,"sku":"REL52055","price":2081.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/365aaa52579b31214afe1ea9dcca24cf94012fed-large.png?v=1691423244"},{"product_id":"rel52121-easergy-p3m32-6ct-3io-ringlug-4vt-12di-14do-110-230v-di110v-rs485","title":"Easergy P3M32 6CT 3Io ringlug 4VT 12DI 14DO 110-230V DI110V RS485 RJ45 ANSI","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring Function: trip circuit supervision 74 || circuit breaker monitoring || relay self-monitoring\u003c\/li\u003e\n\u003cli\u003eAnalogue Output Number: 0\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Number: 0\u003c\/li\u003e\n\u003cli\u003eRelay Type: differential current relay\u003c\/li\u003e\n\u003cli\u003eInput Type: 6 1\/5 A CT phase current || 2 5\/1 A CT residual current || 1 1\/0.2 A CT residual current || 4 100 V\/110 V VT voltage\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: screw removable (digital input\/output) || ring lugs fixed (current transformer) || pin removable (voltage transformer)\u003c\/li\u003e\n\u003cli\u003eNetwork And Machine Diagnosis Type: event recording || disturbance recording || tripping context\u003c\/li\u003e\n\u003cli\u003eDevice Mounting: flush\u003c\/li\u003e\n\u003cli\u003eControl Type: switchgear control and monitoring || programmable switchgear interlocking || local control on single-line diagram || local control with I\/O keys || local\/remote control || 2 function keys || mobile application with Easergy SmartApp || web-server\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 14 DO || 1 watchdog\u003c\/li\u003e\n\u003cli\u003eDigital Input Number: 12.0\u003c\/li\u003e\n\u003cli\u003eSetting: 4\u003c\/li\u003e\n\u003cli\u003eProtection Type: synchro-check 25 || undervoltage 27 || directional active underpower 37P || phase undercurrent 37 || negative sequence overcurrent 46 || negative sequence overvoltage 47 || excessive starting time, locked rotor 48\/51LR || thermal overload protection 49 || earth fault overcurrent 50N\/51N || phase overcurrent 50\/51 || breaker failure 50BF || switch ON to fault (SOTF) || capacitor bank unbalance 51C || capacitor overvoltage 59C || overvoltage 59 || earth fault overvoltage 59N || stator earth fault 64S || restricted earth fault 64REF || motor restart inhibition 66 || directional phase overcurrent 67 || directional earth fault 67N || H2 detection 68H2 || H5 detection 68H5 || underfrequency 81\/81N || rate of change of frequency 81R || lockout relay 86 || machine differential 87M || programmable stages 99 || programmable curve || cold load pick-up\u003c\/li\u003e\n\u003cli\u003eRelay Application: motor\u003c\/li\u003e\n\u003cli\u003eIntegrated Connection Type: front USB port 1 || rear RJ45 1 || rear RS485 1\u003c\/li\u003e\n\u003cli\u003eCybersecurity: password protection || port hardening\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: IEC 61850 ed. 1 || IEC 61850 ed. 2 || IEC 60870-5-101 || DNP3 TCP || Modbus TCP || EtherNet\/IP || IEC 60870-5-103 || DNP3 || Modbus RTU || DeviceNet || SPAbus\u003c\/li\u003e\n\u003cli\u003eNumber Of Sensors: 0 temperature || 0 arc\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: protection relay\u003c\/li\u003e\n\u003cli\u003eSwitchgear Diagnosis Type: CT\/VT supervision || trip circuit supervision TCS\u003c\/li\u003e\n\u003cli\u003eArc Flash Protection: no\u003c\/li\u003e\n\u003cli\u003eSingle Line Diagram: 6 controlled + 8 displayed\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current 3-phase || current zero sequence || current positive sequence || current negative sequence || current ratio of negative and positive || voltage phase to earth || voltage phase to phase || voltage zero sequence || voltage positive sequence || voltage negative sequence || voltage ratio of negative and positive || short circuit fault reactance || fault location current || earth fault reactance || frequency || active power || RMS active power || reactive power || RMS reactive power || apparent power || RMS apparent power || active energy || reactive energy || cos φ || tan φ || power angle || power factor || voltage phasor diagram view || current phasor diagram view || current 2nd, 15th harmonics with THD || voltage 2nd, 15th harmonics with THD || condition monitoring CB wear || voltage interruption\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: P3M32-CGG1A-AA1FA-BBAAB\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 48...230 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNumber Of Key: 2 customizable\u003c\/li\u003e\n\u003cli\u003eOperating Threshold: 110 V AC\/DC\u003c\/li\u003e\n\u003cli\u003eTime Synchronisation Protocol: SNTP\u003c\/li\u003e\n\u003cli\u003eWidth: 270 mm\u003c\/li\u003e\n\u003cli\u003eHeight: 176 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: and LCD 128 x 128 pixels with single line diagram || and LCD 128 x 128 pixels with ANSI symbols\u003c\/li\u003e\n\u003cli\u003eNet Weight: 4.2 kg maximum\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: 2 LEDs || 16 LEDs programmable\u003c\/li\u003e\n\u003cli\u003eDepth: 230 mm\u003c\/li\u003e\n\u003cli\u003eWeb Server: embedded HTTP server\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eElectromagnetic Compatibility: emission tests IEC\/EN 60255-26 ed. 3 || emission tests class A CISPR 11 || emission tests class A CISPR 22 || EMC immunity IEC\/EN 60255-26 ed. 3 || EMC immunity EN\/IEC 61000-4-18 || EMC immunity IEC 60255-22-1 || EMC immunity level 4 EN\/IEC 61000-4-2 || EMC immunity IEC 60255-22-2 || EMC immunity level 3 EN\/IEC 61000-4-3 || EMC immunity IEC 60255-22-3 || EMC immunity level 4 EN\/IEC 61000-4-4 || EMC immunity IEC 60255-22-4 || EMC immunity level 3 EN\/IEC 61000-4-5 || EMC immunity IEC 60255-22-5 || EMC immunity level 3 EN\/IEC 61000-4-6 || EMC immunity IEC 60255-22-6 || EMC immunity EN\/IEC 61000-4-8 || EMC immunity level 5 EN\/IEC 61000-4-9 || EMC immunity EN\/IEC 61000-4-29 || EMC immunity EN\/IEC 61000-4-11 || EMC immunity EN\/IEC 61000-4-17 || EMC immunity IEC 60255-27 || EMC immunity class III IEC 60255-5 || EMC immunity EN\/IEC 60255-1\u003c\/li\u003e\n\u003cli\u003eMechanical Robustness: vibrations class II) IEC 60255-21-1 || vibrationsFc IEC 60068-2-6 || shocks class II) IEC 60255-21-2 || shocksEa IEC 60068-2-27 || seismic tests method A class II) IEC 60255-21-3\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 %, without condensation\u003c\/li\u003e\n\u003cli\u003eProtective Treatment: conformal coating\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -40-65 °C\u003c\/li\u003e\n\u003cli\u003eEnvironmental Characteristic: exposure to dry heat Bd EN\/IEC 60068-2-2 || exposure to cold Ad EN\/IEC 60068-2-1 || exposure to damp heat in service Db EN\/IEC 60068-2-30 || exposure to damp heat in service Cab EN\/IEC 60068-2-78\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 6561.68 ft (2000 m)\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: IP54 conforming to IEC 60529\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4962513f658b15cd190c323900b0e48d00015ac5.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a48dc51f852c578c3abbd8ac8a0faf59ae5a264.pdf\" target=\"_blank\"\u003eEasergy P3G30 and P3G32 User Guide - P3G30_32_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b4871d34d72c88b352d5a0d5ebe1fbb3e6216960.pdf\" target=\"_blank\"\u003eEasergy P3F30 - P3F30_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/80265de0075a3cc11a75b3853d1a63bca68d5d51.pdf\" target=\"_blank\"\u003eEasergy P3L30 User Guide - P3L30_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c94177e5f9691d30cfb328401d2ca08299d575f7.pdf\" target=\"_blank\"\u003eEasergy P3M30 and P3M32 User Guide - P3M30_32_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8cdae4f25cb97a4198e9ba796ff5a15bc9cd3474.pdf\" target=\"_blank\"\u003eEasergy P3T32 - P3T32_en_M_K006_IEC_web (pdf)\u003c\/a\u003e\u003ch4\u003eApplication Notes\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0ff6459f9bb78de952326864964e6e9da65e6d88.zip\" target=\"_blank\"\u003eEnglish - P3Ux_dimensional_DWG.zip\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/19d65855cf19cf7b9340731694b0a45ce159b66e.pdf\" target=\"_blank\"\u003eEasergy P3 Advanced - Quick Start guide - P3X_en_QS_07_IEC_web (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a54f0637bef0445184d9c3e4e4c7029e63ad347f.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3x3x_Capbank (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fc1364ec461148fff0b26b21b4a64588ff863e23.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3T32_connection_v1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0f8f00126a28bbb90bc0d7febdc59325df2d790f.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3G32_v1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e1c82fc51cae22acb619f49f8691159bdfb37c5d.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x3x_connection_3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47adb3e32c9fe9cb4a43c93f0c5bdb0a2031b21b.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M32_motor_connection (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/feac83b0d2b75d503c9484e475155fb7255e0217.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3T32_connection_v1 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/45caa67a5ab8ac3a74976bc2d7f59965439fb3f3.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3G32_v1 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6c463c3ab9b22939f9aa90b03beeb1413d45bebd.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M30_3LN_Uo_connection (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3742ab17f0dccedc962961ca47880bd3fee64d9e.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M30_3LN_Uo_connection (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/eadf9804c998f83b3b9d6a4ead681aaeb94284c5.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x3x_connection_3 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/64701dd265704d066fb31db964bf361cc4eee37a.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x30_connection_3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a89219d333cd8e673743cfb616d2763c0a23f82.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M32_motor_connection (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/689e9054befa6381dc7888776cd5e5229b7e69bc.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x30_connection_3 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a41453394d007d103e8c59d7260dbc68c4186502.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3x3x_Capbank (pdf)\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d7302fd9c9cb5f5d7a12e0ec31d74658f18bd5cf.pdf\" target=\"_blank\"\u003eEnglish - 18-2173_Rev1_DNVGL_SchneiderElectric_P3U30_P3F30_P3G30_P3G32_P3L30_P3M30... (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46063726035248,"sku":"REL52121","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/dbdd54f699590a45f9ba64e62cb7bd5526fd320b-large_7b803d43-2aca-4353-8cf0-321b7187612e.png?v=1691425579"},{"product_id":"rel52056-easergy-p3u-3ct-1io-ringlug-4vt-16di-8do-48-230v-di110v-2rj45","title":"Easergy P3U 3CT 1Io ringlug 4VT 16DI 8DO 48-230V DI110V 2RJ45 ANSI","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring Function: trip circuit supervision 74 || circuit breaker monitoring || relay self-monitoring\u003c\/li\u003e\n\u003cli\u003eRedundancy Communication Port Protocol: RSTP || PRP\u003c\/li\u003e\n\u003cli\u003eAnalogue Output Number: 0\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Number: 0\u003c\/li\u003e\n\u003cli\u003eInput Type: 3 1\/5 A CT phase current || 1 1\/5 A CT residual current || 4 100 V\/110 V VT voltage\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: screw removable (digital input\/output) || ring lugs removable (current transformer) || pin removable (voltage transformer)\u003c\/li\u003e\n\u003cli\u003eNetwork And Machine Diagnosis Type: event recording || disturbance recording || tripping context\u003c\/li\u003e\n\u003cli\u003eDevice Mounting: flush\u003c\/li\u003e\n\u003cli\u003eControl Type: switchgear control and monitoring || programmable switchgear interlocking || local control on single-line diagram || local control with I\/O keys || local\/remote control || 2 function keys || mobile application with Easergy SmartApp || web-server\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 8 DO || 1 watchdog\u003c\/li\u003e\n\u003cli\u003eDigital Input Number: 16.0\u003c\/li\u003e\n\u003cli\u003eSetting: 4\u003c\/li\u003e\n\u003cli\u003eProtection Type: phase overcurrent 50\/51 || directional phase overcurrent 67 || earth fault overcurrent 50N\/51N || directional earth fault 67N || transient earth fault 67NI || capacitor bank unbalance 51C || broken conductor 46 I2\/I1 || cold load pick-up || H2 detection 68H2 || H5 detection 68H5 || breaker failure 50BF || switch ON to fault (SOTF) || directional active underpower 37P || fault locator 21FL || recloser 79 || phase undercurrent 37 || excessive starting time, locked rotor 48\/51LR || motor restart inhibition 66 || capacitor overvoltage 59C || negative sequence overcurrent 46 || overvoltage 59 || undervoltage 27 || positive sequence undervoltage 27P || earth fault overvoltage 59N || underfrequency 81\/81N || rate of change of frequency 81R || synchro-check 25 || lockout relay 86 || CT supervision 60 || VT supervision 60 || programmable stages 99 || programmable curve\u003c\/li\u003e\n\u003cli\u003eRelay Application: universal\u003c\/li\u003e\n\u003cli\u003eIntegrated Connection Type: front USB port 1 || rear RJ45 2\u003c\/li\u003e\n\u003cli\u003eCybersecurity: password protection || port hardening\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: IEC 61850 ed. 1 || IEC 61850 ed. 2 || IEC 60870-5-101 || DNP3 TCP || Modbus TCP || EtherNet\/IP\u003c\/li\u003e\n\u003cli\u003eNumber Of Sensors: 0 temperature || 0 arc\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: protection relay\u003c\/li\u003e\n\u003cli\u003eSwitchgear Diagnosis Type: CT supervision || trip circuit supervision TCS\u003c\/li\u003e\n\u003cli\u003eArc Flash Protection: no\u003c\/li\u003e\n\u003cli\u003eSingle Line Diagram: 4 controlled + 8 displayed\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current 3-phase || current zero sequence || current positive sequence || current negative sequence || current ratio of negative and positive || voltage phase to earth || voltage phase to phase || voltage zero sequence || voltage positive sequence || voltage negative sequence || voltage ratio of negative and positive || short circuit fault reactance || fault location current || earth fault reactance || frequency || active power || RMS active power || reactive power || RMS reactive power || apparent power || RMS apparent power || active energy || reactive energy || cos φ || tan φ || power angle || power factor || voltage phasor diagram view || current phasor diagram view || current 2nd, 15th harmonics with THD || voltage 2nd, 15th harmonics with THD || condition monitoring CB wear || voltage interruption\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: P3U30-6AAA2BCAB\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 48...230 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNumber Of Key: 2 customizable\u003c\/li\u003e\n\u003cli\u003eOperating Threshold: 110 V AC\/DC\u003c\/li\u003e\n\u003cli\u003eTime Synchronisation Protocol: SNTP\u003c\/li\u003e\n\u003cli\u003eWidth: 170 mm\u003c\/li\u003e\n\u003cli\u003eHeight: 169.5 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: and LCD 128 x 64 pixels with single line diagram || and LCD 128 x 64 pixels with ANSI symbols\u003c\/li\u003e\n\u003cli\u003eNet Weight: 2.5 kg maximum\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: 4 LEDs || 8 LEDs programmable\u003c\/li\u003e\n\u003cli\u003eDepth: 205 mm\u003c\/li\u003e\n\u003cli\u003eWeb Server: embedded HTTP server\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eElectromagnetic Compatibility: emission tests IEC\/EN 60255-26 ed. 3 || emission tests class A CISPR 11 || emission tests class A CISPR 22 || EMC immunity IEC\/EN 60255-26 ed. 3 || EMC immunity EN\/IEC 61000-4-18 || EMC immunity IEC 60255-22-1 || EMC immunity level 4 EN\/IEC 61000-4-2 || EMC immunity IEC 60255-22-2 || EMC immunity level 3 EN\/IEC 61000-4-3 || EMC immunity IEC 60255-22-3 || EMC immunity level 4 EN\/IEC 61000-4-4 || EMC immunity IEC 60255-22-4 || EMC immunity level 3 EN\/IEC 61000-4-5 || EMC immunity IEC 60255-22-5 || EMC immunity level 3 EN\/IEC 61000-4-6 || EMC immunity IEC 60255-22-6 || EMC immunity EN\/IEC 61000-4-8 || EMC immunity level 5 EN\/IEC 61000-4-9 || EMC immunity EN\/IEC 61000-4-29 || EMC immunity EN\/IEC 61000-4-11 || EMC immunity EN\/IEC 61000-4-17 || EMC immunity IEC 60255-27 || EMC immunity class III IEC 60255-5 || EMC immunity EN\/IEC 60255-1\u003c\/li\u003e\n\u003cli\u003eMechanical Robustness: vibrations class II) IEC 60255-21-1 || vibrationsFc IEC 60068-2-6 || shocks class II) IEC 60255-21-2 || shocksEa IEC 60068-2-27 || seismic tests method A class II) IEC 60255-21-3\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 %, without condensation\u003c\/li\u003e\n\u003cli\u003eProtective Treatment: conformal coating\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -40-65 °C\u003c\/li\u003e\n\u003cli\u003eEnvironmental Characteristic: exposure to dry heat Bd EN\/IEC 60068-2-2 || exposure to cold Ad EN\/IEC 60068-2-1 || exposure to damp heat in service Db EN\/IEC 60068-2-30 || exposure to damp heat in service Cab EN\/IEC 60068-2-78\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 6561.68 ft (2000 m)\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: IP54 conforming to IEC 60529\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea80ab576b747c59c7d7a6bdfb01a2daca54c10e.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38c1efaee50d52ddfe104831176050463a0170d7.zip\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - VVPA3CG_EN_M_D004 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b3f738678c81755b9daa2b009245559efd15a95a.pdf\" target=\"_blank\"\u003eUser Guide Easergy P3Ux - P3U_en_M_K006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/17dc7ff5bd41441df5d454046bfb8b344f2b7a5f.pdf\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - eSetup+Easergy+Pro+Setting+Tool+Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fe15d0cfb54a548fe86b90f47e09cf94f48d0d9e.zip\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - VVSE2_EN_M_B007 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3b68f26cf951a7e327bd10ca83840d2985f5bed0.pdf\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - VVSE1_EN_M_B007 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a2c8c7c9e9c2787423b995cd1a8e12f914d90471.pdf\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - P3_P3TDS17006_en_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/114fc7a1cc6108829135f7e6dbd50c59281a35c2.pdf\" target=\"_blank\"\u003eRTD I\/O unit manual - VVIO12A_EN_M_D001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3901d75d75124610f0e011798db32c45fc119bd8.pdf\" target=\"_blank\"\u003eEasergy P3 Protection Relays' Accessories User Manuals - VVIO12A_EN_M_D002_print (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0086ace2f95595ae728f52e2075135ccb8c97c94.pdf\" target=\"_blank\"\u003eProfibus adapter - VVPA3CG_EN_M_C004 (pdf)\u003c\/a\u003e\u003ch4\u003eApplication Notes\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0ff6459f9bb78de952326864964e6e9da65e6d88.zip\" target=\"_blank\"\u003eEnglish - P3Ux_dimensional_DWG.zip\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/70b557636039bed0b3aa52979141a2ae658f0d20.pdf\" target=\"_blank\"\u003ePowerLogic™ Easergy P3 Catalog - P3_NRJCAT17764EN_v21 (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a41453394d007d103e8c59d7260dbc68c4186502.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3x3x_Capbank (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/eadf9804c998f83b3b9d6a4ead681aaeb94284c5.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x3x_connection_3 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/45caa67a5ab8ac3a74976bc2d7f59965439fb3f3.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3G32_v1 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a89219d333cd8e673743cfb616d2763c0a23f82.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M32_motor_connection (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6c463c3ab9b22939f9aa90b03beeb1413d45bebd.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M30_3LN_Uo_connection (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3742ab17f0dccedc962961ca47880bd3fee64d9e.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M30_3LN_Uo_connection (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/feac83b0d2b75d503c9484e475155fb7255e0217.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3T32_connection_v1 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0f8f00126a28bbb90bc0d7febdc59325df2d790f.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3G32_v1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fc1364ec461148fff0b26b21b4a64588ff863e23.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3T32_connection_v1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/689e9054befa6381dc7888776cd5e5229b7e69bc.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x30_connection_3 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47adb3e32c9fe9cb4a43c93f0c5bdb0a2031b21b.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M32_motor_connection (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a54f0637bef0445184d9c3e4e4c7029e63ad347f.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3x3x_Capbank (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e1c82fc51cae22acb619f49f8691159bdfb37c5d.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x3x_connection_3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/64701dd265704d066fb31db964bf361cc4eee37a.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x30_connection_3 (pdf)\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d7302fd9c9cb5f5d7a12e0ec31d74658f18bd5cf.pdf\" target=\"_blank\"\u003eEnglish - 18-2173_Rev1_DNVGL_SchneiderElectric_P3U30_P3F30_P3G30_P3G32_P3L30_P3M30... (pdf)\u003c\/a\u003e\u003ch4\u003eQuick start guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fe11d31e2be45ee29a1733b66095036bc0938a4f.pdf\" target=\"_blank\"\u003eEasergy P3 - Universal Relays P3U10, P3U20 and P3U30 - Quick Start guide - P3U_en_QS_07_IEC_web (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46063918481712,"sku":"REL52056","price":2107.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/365aaa52579b31214afe1ea9dcca24cf94012fed-large_996960cb-f561-455c-9950-12890419a542.png?v=1691426629"},{"product_id":"rel52128-easergy-p3f30-3ct-2io-ringlug-4vt-6di-10do-110-230v-di110v-3bio","title":"Easergy P3F30 3CT 2Io ringlug 4VT 6DI 10DO 110-230V DI110V 3BIO 6ARC RS485 RJ45 ANSI","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring Function: trip circuit supervision 74 || circuit breaker monitoring || relay self-monitoring\u003c\/li\u003e\n\u003cli\u003eAnalogue Output Number: 0\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Number: 0\u003c\/li\u003e\n\u003cli\u003eInput Type: 3 1\/5 A CT phase current || 1 5\/1 A CT residual current || 1 1\/0.2 A CT residual current || 4 100 V\/110 V VT voltage\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: screw removable (digital input\/output) || ring lugs fixed (current transformer) || pin removable (voltage transformer)\u003c\/li\u003e\n\u003cli\u003eNetwork And Machine Diagnosis Type: event recording || disturbance recording || tripping context\u003c\/li\u003e\n\u003cli\u003eDevice Mounting: flush\u003c\/li\u003e\n\u003cli\u003eControl Type: switchgear control and monitoring || programmable switchgear interlocking || local control on single-line diagram || local control with I\/O keys || local\/remote control || 2 function keys || mobile application with Easergy SmartApp || web-server\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 10 DO || 1 watchdog\u003c\/li\u003e\n\u003cli\u003eDigital Input Number: 6.0\u003c\/li\u003e\n\u003cli\u003eSetting: 4\u003c\/li\u003e\n\u003cli\u003eProtection Type: fault locator 21FL || synchro-check 25 || undervoltage 27 || directional active underpower 37P || broken conductor 46BC || thermal overload protection 49 || earth fault overcurrent 50N\/51N || phase overcurrent 50\/51 || breaker failure 50BF || switch ON to fault (SOTF) || capacitor bank unbalance 51C || voltage-restrained overcurrent 51V || capacitor overvoltage 59C || overvoltage 59 || earth fault overvoltage 59N || directional phase overcurrent 67 || directional earth fault 67N || transient earth fault 67NI || H2 detection 68H2 || H5 detection 68H5 || recloser 79 || underfrequency 81\/81N || rate of change of frequency 81R || lockout relay 86 || programmable stages 99 || programmable curve || cold load pick-up\u003c\/li\u003e\n\u003cli\u003eRelay Application: feeder\u003c\/li\u003e\n\u003cli\u003eIntegrated Connection Type: front USB port 1 || rear RJ45 1 || rear RS485 1\u003c\/li\u003e\n\u003cli\u003eCybersecurity: password protection || port hardening\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: IEC 61850 ed. 1 || IEC 61850 ed. 2 || IEC 60870-5-101 || DNP3 TCP || Modbus TCP || EtherNet\/IP || IEC 60870-5-103 || DNP3 || Modbus RTU || DeviceNet || SPAbus\u003c\/li\u003e\n\u003cli\u003eNumber Of Sensors: 0 temperature || 0 arc\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: protection relay\u003c\/li\u003e\n\u003cli\u003eSwitchgear Diagnosis Type: CT\/VT supervision || trip circuit supervision TCS\u003c\/li\u003e\n\u003cli\u003eArc Flash Protection: yes\u003c\/li\u003e\n\u003cli\u003eSingle Line Diagram: 3 controlled + 5 displayed\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current 3-phase || current zero sequence || current positive sequence || current negative sequence || current ratio of negative and positive || voltage phase to earth || voltage phase to phase || voltage zero sequence || voltage positive sequence || voltage negative sequence || voltage ratio of negative and positive || short circuit fault reactance || fault location current || earth fault reactance || frequency || active power || RMS active power || reactive power || RMS reactive power || apparent power || RMS apparent power || active energy || reactive energy || cos φ || tan φ || power angle || power factor || voltage phasor diagram view || current phasor diagram view || current 2nd, 15th harmonics with THD || voltage 2nd, 15th harmonics with THD || condition monitoring CB wear || voltage interruption\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: P3F30-CBGAD-DA1FA-BBAAB\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 48...230 V AC\/DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNumber Of Key: 2 customizable\u003c\/li\u003e\n\u003cli\u003eOperating Threshold: 110 V AC\/DC\u003c\/li\u003e\n\u003cli\u003eTime Synchronisation Protocol: SNTP\u003c\/li\u003e\n\u003cli\u003eWidth: 270 mm\u003c\/li\u003e\n\u003cli\u003eHeight: 176 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: and LCD 128 x 128 pixels with single line diagram || and LCD 128 x 128 pixels with ANSI symbols\u003c\/li\u003e\n\u003cli\u003eNet Weight: 4.2 kg maximum\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: 2 LEDs || 16 LEDs programmable\u003c\/li\u003e\n\u003cli\u003eDepth: 230 mm\u003c\/li\u003e\n\u003cli\u003eWeb Server: embedded HTTP server\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eElectromagnetic Compatibility: emission tests IEC\/EN 60255-26 ed. 3 || emission tests class A CISPR 11 || emission tests class A CISPR 22 || EMC immunity IEC\/EN 60255-26 ed. 3 || EMC immunity EN\/IEC 61000-4-18 || EMC immunity IEC 60255-22-1 || EMC immunity level 4 EN\/IEC 61000-4-2 || EMC immunity IEC 60255-22-2 || EMC immunity level 3 EN\/IEC 61000-4-3 || EMC immunity IEC 60255-22-3 || EMC immunity level 4 EN\/IEC 61000-4-4 || EMC immunity IEC 60255-22-4 || EMC immunity level 3 EN\/IEC 61000-4-5 || EMC immunity IEC 60255-22-5 || EMC immunity level 3 EN\/IEC 61000-4-6 || EMC immunity IEC 60255-22-6 || EMC immunity EN\/IEC 61000-4-8 || EMC immunity level 5 EN\/IEC 61000-4-9 || EMC immunity EN\/IEC 61000-4-29 || EMC immunity EN\/IEC 61000-4-11 || EMC immunity EN\/IEC 61000-4-17 || EMC immunity IEC 60255-27 || EMC immunity class III IEC 60255-5 || EMC immunity EN\/IEC 60255-1\u003c\/li\u003e\n\u003cli\u003eMechanical Robustness: vibrations class II) IEC 60255-21-1 || vibrationsFc IEC 60068-2-6 || shocks class II) IEC 60255-21-2 || shocksEa IEC 60068-2-27 || seismic tests method A class II) IEC 60255-21-3\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 %, without condensation\u003c\/li\u003e\n\u003cli\u003eProtective Treatment: conformal coating\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -40-65 °C\u003c\/li\u003e\n\u003cli\u003eEnvironmental Characteristic: exposure to dry heat Bd EN\/IEC 60068-2-2 || exposure to cold Ad EN\/IEC 60068-2-1 || exposure to damp heat in service Db EN\/IEC 60068-2-30 || exposure to damp heat in service Cab EN\/IEC 60068-2-78\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 6561.68 ft (2000 m)\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: IP54 conforming to IEC 60529\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e72e6d30b2c4775dc9587fd941ff8cb156b80ff1.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c94177e5f9691d30cfb328401d2ca08299d575f7.pdf\" target=\"_blank\"\u003eEasergy P3M30 and P3M32 User Guide - P3M30_32_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a48dc51f852c578c3abbd8ac8a0faf59ae5a264.pdf\" target=\"_blank\"\u003eEasergy P3G30 and P3G32 User Guide - P3G30_32_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/80265de0075a3cc11a75b3853d1a63bca68d5d51.pdf\" target=\"_blank\"\u003eEasergy P3L30 User Guide - P3L30_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8cdae4f25cb97a4198e9ba796ff5a15bc9cd3474.pdf\" target=\"_blank\"\u003eEasergy P3T32 - P3T32_en_M_K006_IEC_web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b4871d34d72c88b352d5a0d5ebe1fbb3e6216960.pdf\" target=\"_blank\"\u003eEasergy P3F30 - P3F30_en_M_J006_IEC_web (pdf)\u003c\/a\u003e\u003ch4\u003eApplication Notes\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0ff6459f9bb78de952326864964e6e9da65e6d88.zip\" target=\"_blank\"\u003eEnglish - P3Ux_dimensional_DWG.zip\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/19d65855cf19cf7b9340731694b0a45ce159b66e.pdf\" target=\"_blank\"\u003eEasergy P3 Advanced - Quick Start guide - P3X_en_QS_07_IEC_web (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0f8f00126a28bbb90bc0d7febdc59325df2d790f.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3G32_v1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/45caa67a5ab8ac3a74976bc2d7f59965439fb3f3.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3G32_v1 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6c463c3ab9b22939f9aa90b03beeb1413d45bebd.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M30_3LN_Uo_connection (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e1c82fc51cae22acb619f49f8691159bdfb37c5d.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x3x_connection_3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a41453394d007d103e8c59d7260dbc68c4186502.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3x3x_Capbank (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3742ab17f0dccedc962961ca47880bd3fee64d9e.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M30_3LN_Uo_connection (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47adb3e32c9fe9cb4a43c93f0c5bdb0a2031b21b.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M32_motor_connection (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/feac83b0d2b75d503c9484e475155fb7255e0217.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3T32_connection_v1 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/64701dd265704d066fb31db964bf361cc4eee37a.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x30_connection_3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a54f0637bef0445184d9c3e4e4c7029e63ad347f.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3x3x_Capbank (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fc1364ec461148fff0b26b21b4a64588ff863e23.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3T32_connection_v1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/689e9054befa6381dc7888776cd5e5229b7e69bc.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x30_connection_3 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/eadf9804c998f83b3b9d6a4ead681aaeb94284c5.dwg\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - 3LN_Uo_P3x3x_connection_3 (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a89219d333cd8e673743cfb616d2763c0a23f82.pdf\" target=\"_blank\"\u003eEasergy P3 connection diagrams Technical drawings - P3M32_motor_connection (pdf)\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d7302fd9c9cb5f5d7a12e0ec31d74658f18bd5cf.pdf\" target=\"_blank\"\u003eEnglish - 18-2173_Rev1_DNVGL_SchneiderElectric_P3U30_P3F30_P3G30_P3G32_P3L30_P3M30... (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46064313106736,"sku":"REL52128","price":3079.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/dbdd54f699590a45f9ba64e62cb7bd5526fd320b-large_4a31e17d-d193-44cd-9f5c-055c11da5c5f.png?v=1691429594"},{"product_id":"rel52822-usb-programming-cable-easergy-pro","title":"USB programming cable (Easergy Pro)","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: USB type A USB\u003c\/li\u003e\n\u003cli\u003eIntegrated Connection Type: USB type B\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eCable Length: 3 m\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: programming cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1411007\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1411007\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d028ed856e76b2c0a307cf9677e2a35b554215fa.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/147cbd889a478761af04e16568a0e79918be2a7f.zip\" target=\"_blank\"\u003eWAVEWIN Data Management and Analysis System software - Wavewin-SE+Menu+H.P.10.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5bd645c49ce3d0361e33f3f766e97453078052b.zip\" target=\"_blank\"\u003eCET850 IEC 61850 configuration tool V4.5.1 - CET850-V4.5.1.zip\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/848ea41a6a023fbf19ddef3fc98dafceef4a803f.pdf\" target=\"_blank\"\u003eSepam Series 80, Circularity Profile, End of Life Instructions - ENVEOLI1411007_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/badaa033a3296ea0ca888d12dad0cc8f3e4b18c3.pdf\" target=\"_blank\"\u003eSepam Series 80, Environmental Disclosure, Product Environmental Profile - ENVPEP1411007_V1 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46067527614768,"sku":"REL52822","price":18.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/a2902a260394db36fdcb2c97abaefffd8c2fd024-large.png?v=1691442037"},{"product_id":"rel52803-arc-sensor-20-m-shielded","title":"Arc sensor, 20 m, shielded","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e[Sn] Nominal Sensing Distance: 400-1100 nm\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: arc sensor\u003c\/li\u003e\n\u003cli\u003eType Of Cable: shielded cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 25 mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 20 m\u003c\/li\u003e\n\u003cli\u003eWidth: 55 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 14 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 0.9 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1411007\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1411007\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a44146301ce3f9688c700b7577bb196bc958b904.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2d641b16fc35ea47bad6185ee7c63a0d4ae3300d.STEP\" target=\"_blank\"\u003eArc point sensor with shielded cable VA1DA - VA1DA.STEP\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c5ab227ed522590a24de21c7bc86907a9a3f34da.zip\" target=\"_blank\"\u003eVA 1 DA - Arc sensor - User Guide - VA1DA_EN_M_E001 (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0f78983d788713c4e7441c7a214bbaa1f3d8a735.zip\" target=\"_blank\"\u003eVA 1 DA - Arc sensor - User Manual - VA1DA_EN_M_E001 (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5bd645c49ce3d0361e33f3f766e97453078052b.zip\" target=\"_blank\"\u003eCET850 IEC 61850 configuration tool V4.5.1 - CET850-V4.5.1.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/147cbd889a478761af04e16568a0e79918be2a7f.zip\" target=\"_blank\"\u003eWAVEWIN Data Management and Analysis System software - Wavewin-SE+Menu+H.P.10.zip\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/848ea41a6a023fbf19ddef3fc98dafceef4a803f.pdf\" target=\"_blank\"\u003eSepam Series 80, Circularity Profile, End of Life Instructions - ENVEOLI1411007_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/badaa033a3296ea0ca888d12dad0cc8f3e4b18c3.pdf\" target=\"_blank\"\u003eSepam Series 80, Environmental Disclosure, Product Environmental Profile - ENVPEP1411007_V1 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46067716620592,"sku":"REL52803","price":125.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/baac0350199934ad9f31226b9dd747d2d2b1fb84-large.png?v=1691442538"},{"product_id":"rel52806-arc-sensor-6m-shielded","title":"Arc sensor, 6m, shielded","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e[Sn] Nominal Sensing Distance: 400-1100 nm\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eQuantity Per Set: 1 piece\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: arc sensor\u003c\/li\u003e\n\u003cli\u003eType Of Cable: shielded cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 25 mm\u003c\/li\u003e\n\u003cli\u003eCable Length: 6 m\u003c\/li\u003e\n\u003cli\u003eWidth: 55 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 14 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 0.3 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1411007\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1411007\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/800e6dccc17fe628f797ff2494713b7644084932.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2d641b16fc35ea47bad6185ee7c63a0d4ae3300d.STEP\" target=\"_blank\"\u003eArc point sensor with shielded cable VA1DA - VA1DA.STEP\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c5ab227ed522590a24de21c7bc86907a9a3f34da.zip\" target=\"_blank\"\u003eVA 1 DA - Arc sensor - User Guide - VA1DA_EN_M_E001 (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0f78983d788713c4e7441c7a214bbaa1f3d8a735.zip\" target=\"_blank\"\u003eVA 1 DA - Arc sensor - User Manual - VA1DA_EN_M_E001 (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5bd645c49ce3d0361e33f3f766e97453078052b.zip\" target=\"_blank\"\u003eCET850 IEC 61850 configuration tool V4.5.1 - CET850-V4.5.1.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/147cbd889a478761af04e16568a0e79918be2a7f.zip\" target=\"_blank\"\u003eWAVEWIN Data Management and Analysis System software - Wavewin-SE+Menu+H.P.10.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2e7005b6586053c6852e7a9405463d41b97f2be1.exe\" target=\"_blank\"\u003eeSetup Easergy Pro V4.4.0 - eSetup+Easergy+Pro+V4.4.0+Installer.exe\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/848ea41a6a023fbf19ddef3fc98dafceef4a803f.pdf\" target=\"_blank\"\u003eSepam Series 80, Circularity Profile, End of Life Instructions - ENVEOLI1411007_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/badaa033a3296ea0ca888d12dad0cc8f3e4b18c3.pdf\" target=\"_blank\"\u003eSepam Series 80, Environmental Disclosure, Product Environmental Profile - ENVPEP1411007_V1 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46067716849968,"sku":"REL52806","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/baac0350199934ad9f31226b9dd747d2d2b1fb84-large_c6cad866-ca94-4824-a8fb-ccd8e3708274.png?v=1691442540"},{"product_id":"rel52810-arc-sensor-6m-shielded-pipe-sensor","title":"Arc sensor, 6m, shielded, pipe sensor","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e[Sn] Nominal Sensing Distance: 400-1100 nm\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3 || VAMP\u003c\/li\u003e\n\u003cli\u003eQuantity Per Set: 1 piece\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: arc sensor\u003c\/li\u003e\n\u003cli\u003eProduct Compatibility: V121 || V125 || V221 || V321\u003c\/li\u003e\n\u003cli\u003eType Of Cable: shielded cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 11 mm\u003c\/li\u003e\n\u003cli\u003eLight Sensitivity: 8000-10000 lux\u003c\/li\u003e\n\u003cli\u003eResponse Time: 1 ms\u003c\/li\u003e\n\u003cli\u003eVariant: pipe\u003c\/li\u003e\n\u003cli\u003eCable Length: 6 m\u003c\/li\u003e\n\u003cli\u003eWidth: 62 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 11 mm\u003c\/li\u003e\n\u003cli\u003eMaterial: plastic\u003c\/li\u003e\n\u003cli\u003eNet Weight: 0.4 g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1411007\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1411007\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/caee7fedbbebcf402621f00e078c0894c26328b9.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/848ea41a6a023fbf19ddef3fc98dafceef4a803f.pdf\" target=\"_blank\"\u003eSepam Series 80, Circularity Profile, End of Life Instructions - ENVEOLI1411007_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/badaa033a3296ea0ca888d12dad0cc8f3e4b18c3.pdf\" target=\"_blank\"\u003eSepam Series 80, Environmental Disclosure, Product Environmental Profile - ENVPEP1411007_V1 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46084265574704,"sku":"REL52810","price":136.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/39877942c6df04244e3edac9f39e4805ddb53f29-large.png?v=1691492552"},{"product_id":"rel52813-easergy-p3-accessory-vio12acse-24vdc-rtd-module-12-rtd-inputs-4-4","title":"Easergy P3 accessory VIO12ACSE 24VDC RTD module 12 RTD inputs 4\/4 mA in\/out","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 24 V DC\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eMounting Support: 35 mm symmetrical DIN rail || wall mounted\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: analog temperature module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: serial link || fiber optic\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Number: 4\u003c\/li\u003e\n\u003cli\u003eTemperature Probe Type: Pt 100, Ni 100, Ni 120, Cu 10\u003c\/li\u003e\n\u003cli\u003eAnalogue Output Number: 4\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 12 RTD temperature sensor) || 1 PTC temperature sensor)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1411007\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1411007\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eAmbient Air Temperature For Operation: 0-55 °C\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/90dec2335c91ccfeea2f279fe2979b5fe8317107.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/114fc7a1cc6108829135f7e6dbd50c59281a35c2.pdf\" target=\"_blank\"\u003eRTD I\/O unit manual - VVIO12A_EN_M_D001 (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5bd645c49ce3d0361e33f3f766e97453078052b.zip\" target=\"_blank\"\u003eCET850 IEC 61850 configuration tool V4.5.1 - CET850-V4.5.1.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/147cbd889a478761af04e16568a0e79918be2a7f.zip\" target=\"_blank\"\u003eWAVEWIN Data Management and Analysis System software - Wavewin-SE+Menu+H.P.10.zip\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/848ea41a6a023fbf19ddef3fc98dafceef4a803f.pdf\" target=\"_blank\"\u003eSepam Series 80, Circularity Profile, End of Life Instructions - ENVEOLI1411007_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0ba17a55f093e0f4c1cce37446482547a5c3c5d5.pdf\" target=\"_blank\"\u003eRTD and mA Input \/ Output Modules - VIO 12AA\/AB and VIO 12AC\/AD - User Manual - VVIO12A_EN_M_D002_web (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/badaa033a3296ea0ca888d12dad0cc8f3e4b18c3.pdf\" target=\"_blank\"\u003eSepam Series 80, Environmental Disclosure, Product Environmental Profile - ENVPEP1411007_V1 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46084266000688,"sku":"REL52813","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/398c446ef9d8035c917cf46b72e77d40aa2bc1cc-large.png?v=1691492554"},{"product_id":"rel52814-easergy-p3-accessory-vio12adse-48-230v-rtd-module-12-rtd-inputs-4","title":"Easergy P3 accessory VIO12ADSE 48-230V RTD module 12 RTD inputs 4\/4 mA in\/out","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 48...230 V AC\/DC\u003c\/li\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eMounting Support: wall mounted || 35 mm symmetrical DIN rail\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: analog temperature module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: fiber optic || serial link\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Number: 4\u003c\/li\u003e\n\u003cli\u003eTemperature Probe Type: Pt 100, Ni 100, Ni 120, Cu 10\u003c\/li\u003e\n\u003cli\u003eAnalogue Output Number: 4\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 12 RTD temperature sensor) || 1 PTC temperature sensor)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1411007\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1411007\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eAmbient Air Temperature For Operation: 0-55 °C\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b70f66574119a50d3a7b787d14824888ecb388b1.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/114fc7a1cc6108829135f7e6dbd50c59281a35c2.pdf\" target=\"_blank\"\u003eRTD I\/O unit manual - VVIO12A_EN_M_D001 (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/147cbd889a478761af04e16568a0e79918be2a7f.zip\" target=\"_blank\"\u003eWAVEWIN Data Management and Analysis System software - Wavewin-SE+Menu+H.P.10.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5bd645c49ce3d0361e33f3f766e97453078052b.zip\" target=\"_blank\"\u003eCET850 IEC 61850 configuration tool V4.5.1 - CET850-V4.5.1.zip\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/848ea41a6a023fbf19ddef3fc98dafceef4a803f.pdf\" target=\"_blank\"\u003eSepam Series 80, Circularity Profile, End of Life Instructions - ENVEOLI1411007_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0ba17a55f093e0f4c1cce37446482547a5c3c5d5.pdf\" target=\"_blank\"\u003eRTD and mA Input \/ Output Modules - VIO 12AA\/AB and VIO 12AC\/AD - User Manual - VVIO12A_EN_M_D002_web (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/badaa033a3296ea0ca888d12dad0cc8f3e4b18c3.pdf\" target=\"_blank\"\u003eSepam Series 80, Environmental Disclosure, Product Environmental Profile - ENVPEP1411007_V1 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46084266066224,"sku":"REL52814","price":895.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/398c446ef9d8035c917cf46b72e77d40aa2bc1cc-large_77660ac5-27db-4a3e-918e-685885b87b25.png?v=1691492556"},{"product_id":"rel52820-easergy-p3-accessory-vse002-rs485-module","title":"Easergy P3 accessory VSE002 RS485 module","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: Easergy P3\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: RS485 communication module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eIntegrated Connection Type: RS232\u003c\/li\u003e\n\u003cli\u003eMounting Support: direct mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1411007\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1411007\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Pro-active compliance (Product out of EU RoHS legal scope)\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 73 mm\u003c\/li\u003e\n\u003cli\u003eWidth: 62 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 20 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1ca0d7ec88b97942a621540bf0961c447ef58399.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fe15d0cfb54a548fe86b90f47e09cf94f48d0d9e.zip\" target=\"_blank\"\u003eVSE 002 - External RS-485 module - User manual - VVSE2_EN_M_B007 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38c1efaee50d52ddfe104831176050463a0170d7.zip\" target=\"_blank\"\u003eVPA 3CG Profibus DP Fieldbus Option Board - VVPA3CG_EN_M_D004 (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/147cbd889a478761af04e16568a0e79918be2a7f.zip\" target=\"_blank\"\u003eWAVEWIN Data Management and Analysis System software - Wavewin-SE+Menu+H.P.10.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5bd645c49ce3d0361e33f3f766e97453078052b.zip\" target=\"_blank\"\u003eCET850 IEC 61850 configuration tool V4.5.1 - CET850-V4.5.1.zip\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/848ea41a6a023fbf19ddef3fc98dafceef4a803f.pdf\" target=\"_blank\"\u003eSepam Series 80, Circularity Profile, End of Life Instructions - ENVEOLI1411007_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/badaa033a3296ea0ca888d12dad0cc8f3e4b18c3.pdf\" target=\"_blank\"\u003eSepam Series 80, Environmental Disclosure, Product Environmental Profile - ENVPEP1411007_V1 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46084266328368,"sku":"REL52820","price":220.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/4fe4b5cd323c122f6e1048ee2717d670c5622b66-large.png?v=1691492560"}],"url":"https:\/\/soliselectricsupply.com\/collections\/protection-relays-by-product-line.oembed","provider":"Solis Electric Supply","version":"1.0","type":"link"}