{"title":"Power Metering and Energy Monitoring Systems","description":"","products":[{"product_id":"metsepm5340-power-meter-powerlogic-pm5340-ethernet-up-to-31st-harmonic","title":"power meter PowerLogic PM5340, ethernet, up to 31st Harmonic, 256KB 2DI\/2DO 35 alarms","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: power meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic PM5000\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: PM5340\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: ETHERNET\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: up to the 31st harmonic\u003c\/li\u003e\n\u003cli\u003eHeight: 96 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 35-760 V AC 45...65 Hz between phases || 20-400 V AC 45...65 Hz between phase and neutral\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 64 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: EN 50470-1 || IEC 62053-24 || IEC 60529 || UL 61010-1 || IEC 62053-22 || EN 50470-3 || IEC 61557-12\u003c\/li\u003e\n\u003cli\u003eMemory Capacity: 256 kB\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 2 relay || 2 digital\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 || cULus UL 61010-1\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current || voltage || frequency || power factor || energy || active and reactive power\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus TCP\/IP 10\/100 Mbit\/s 2500 V || BACnet IP\u003c\/li\u003e\n\u003cli\u003eFrequency Measurement Range: 45-65 Hz\u003c\/li\u003e\n\u003cli\u003eRide-Through Time: 100 ms 120 V AC typical || 400 ms 230 V AC typical || 50 ms 125 V DC typical\u003c\/li\u003e\n\u003cli\u003eDisplay Resolution: 128 x 128 pixels\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 2 digital\u003c\/li\u003e\n\u003cli\u003eNet Weight: 430 g\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 5-9000 mA\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || input\/output circuit screw terminal block6 || relay output screw terminal block4 || Ethernet network RJ45 connector\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: tariff 4)\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...450 V AC 45...65 Hz || 100...300 V DC\u003c\/li\u003e\n\u003cli\u003eMounting Mode: flush-mounted\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: active energy +\/- 0.5 % || reactive energy +\/- 2 % || active power +\/- 0.5 % || apparent power +\/- 0.5 % || frequency +\/- 0.05 % || power factor +\/- 0.5 || current +\/- 0.5 % || voltage +\/- 0.5 % || apparent energy +\/- 0.5 % || reactive power +\/- 2 %\u003c\/li\u003e\n\u003cli\u003eMounting Support: framework\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P || 1P + N || 3P + N\u003c\/li\u003e\n\u003cli\u003eData Recording: data logs || alarm logs || time stamping || event logs || min\/max of instantaneous values || maintenance logs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 5 A || 1 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: voltage 10 MOhm) || current \u0026lt;= 0.3 mOhm)\u003c\/li\u003e\n\u003cli\u003eWidth: 96 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: monochrome graphic LCD\u003c\/li\u003e\n\u003cli\u003eDevice Application: multi-tariff || power monitoring\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.5S active energy IEC 62053-22\u003c\/li\u003e\n\u003cli\u003eMaximum Power Consumption In Va: 11.9 VA 415 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1305025\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1305025\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C meter || -20-70 °C display || -25--20 °C with reduced performance) display\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: limits for harmonic current emissionsclass A IEC 61000-3-2 || electrostatic dischargelevel 4 IEC 61000-4-2 || conducted RF disturbanceslevel 3 IEC 61000-4-6 || magnetic field at power frequencylevel 4 IEC 61000-4-8 || conducted and radiated emissionsclass B EN 55022\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C non-condensing\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: display IP51 IEC 60529 || rear IP30 IEC 60529\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: \u0026lt;= 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/21499c70dba30ac0d914a2ee8bf145439f8b1495.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fac03beb4f5c41632b1e3f5ca8263f7b2ca35a06.dxf\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/00138e98bd1dbfa6867772931d1310e641905d67.dwg\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f5e30b85bae9d0b1af3a485ea8ba996b9956bef5.stp\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_3D-simplified-ec (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/95c4b51590091706ab61aaaa25201cc759648e42.dwg\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/967e21e7a8accdbb0767ffa24a4a2239b5bb43a7.dwg\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/253a52c6a984e9c018030de3c73b35b8a15a4755.dwg\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fe6272729a42e52640c9a45cb36ac7d79dedeba3.pdf\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7147c7648ae0b141d86684e4b8a90e5722a06fef.dwg\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5e35d94a6ad9c8b193e0c022463dac02d76cdedf.dwg\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a797bb41ee9e72af6e5997ca77e0589f0f7409ca.dxf\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9e35b7774346a0636f7bb18ff6365609abb33559.stp\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H, 256K 2DI\/2DO 35 alarms - METSEPM5340_3D-Simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/251048fd9d64bb88101e64004f83a19d2fc3637d.dxf\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d01d9ccc4ad06ad5f0ce16b05e49973618ba7547.dxf\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9da2c527edea89eb76052d8e12cf97a791765adf.dxf\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/02e423cad56f0907891a883d4738f0f6a1f9dc8b.dxf\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/89f19d2b427dad5a51e1f1baf4d43435aaeb2d3c.dwg\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/571a0882b723edf629d3bdfa0144671ea51c98cd.dxf\" target=\"_blank\"\u003ePM5340 Meter, ethernet, up to 31st H - 3D CAD - MCADDE0000230_2D-back (dxf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b521c1e4645ce5423e42d39d947cf03ac8e5398.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Power and Energy Meters Brochure - PowerLogic+PM5000+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a71b8a3a48f1daed421df6bc22e9a31f4986e3f.pdf\" target=\"_blank\"\u003ePowerLogic Power and Energy Meters Catalog - PowerLogic+Catalog+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ffe816d4bb8dfd2f7585f03e86783ae220cf0d0.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Technical Datasheet - PLSED310052EN_(Web) (pdf)\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/574f981375e174c8cb44386871eb8924bff71794.zip\" target=\"_blank\"\u003ePowerlogic PM5320 PM5340 v2.1.5 HW vB1 Firmware Release - PM5320_PM5340_v2.1.5_HW_vB1.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5303640a9f9f06b58fcaca5d651cdc948263bc9c.zip\" target=\"_blank\"\u003ePM53xx (PM5310,PM5320,PM5330,PM5331,PM5340,PM5341) Firmware V2.1.1 and V2.2.1 and associated files - Register List, Revision History, Whats New - PM53xx_2.1.1_2.2.1.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/24c64e376f35b595a12042cea37b07af5d9bece4.zip\" target=\"_blank\"\u003ePM53xx (PM5310,PM5320,PM5330,PM5331,PM5340,PM5341) Firmware V1.5.4 and V1.6.4 and associated files - Register List, Revision History - PM53xx_1.5.4_1.6.4.zip\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2c87361be78b53b5bb5d37945452af9b820c60a7.pdf\" target=\"_blank\"\u003ePM51xx_PM53xx_CE_Certificate - PM51xx+PM53xx+CE+Certification (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/75ec94c90d92ac634aa2b1d1e61611e88ab39c41.pdf\" target=\"_blank\"\u003ePM5000 series_EU Declaration of Conformity - ECDPM5000-V15c (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/923741d21c82780fbe51da8918f5a2759e2bc94c.pdf\" target=\"_blank\"\u003ePM5000 series_Declaration to IEC 61557-12 - Decl+61557-12_PM5100_PM5110_PM5111_PM5310_PM5330_PM5331_PM5320_PM5340_PM5341 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8812ca689ebed9c927da34a59c72e8901ed33a10.pdf\" target=\"_blank\"\u003ePM5000 series_ UK Declaration of conformity - UK_DOC_PM5000-A12-V3 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b512e873207a406717b7fd89377a4813428b08aa.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5300 series - Instruction sheet - HRB69887-12 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e4461d0406e168d1351546a2b71c94705465e63d.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5300 series - User Manual - EAV15107-EN10 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8690396ec045215e2c46db6ead2ffbad9d03d237.pdf\" target=\"_blank\"\u003ePowerLogic PM5000, Environmental Disclosure, Product Environmental Profile - ENVPEP1305025_V2 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5c5e34638efee6327591807916d4cf800890da2c.pdf\" target=\"_blank\"\u003ePowerLogic PM5000, PM5100, PM5300, Circularity Profile, End of Life Instructions - ENVEOLI1305025_V2 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45836577734960,"sku":"METSEPM5340","price":2107.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/6a66a13e698aeedde2dc5c5d191a6d4cf4492470-large.png?v=1690274204"},{"product_id":"metsecab10-powerlogic-pm8000-cable-for-remote-display-rd96-10m","title":"PowerLogic PM8000 - cable for remote display RD96 - 10m","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAccessory \/ Separate Part Category: communication accessory\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: display cable\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic PM8000) || PowerLogic (PowerLogic ION7400)\u003c\/li\u003e\n\u003cli\u003eCable Length: 10 m\u003c\/li\u003e\n\u003cli\u003eAccessory \/ Separate Part Destination: remote display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1406023EN\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1406023EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0e8c3cb1729b27a33c4e6815c0e3ba823bfa801d.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c19e99da0e0df1905086a8b3dd9d125ea3193c9a.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power and Energy Meters Brochure - PM8000+Series+Meter+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/51d26bbb33ebc803cc076adbf77768284594814e.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power Meters eBrochure - PM8000DigitalBRUS_3000AV1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c5826106ca52ddc32a6b8e50d4eba3e5c85b165f.pdf\" target=\"_blank\"\u003ePowerLogic ION7400 Series Technical Datasheet - PLSED310113EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/118d3e5b515ddc36be551f6828604e4716b30fd5.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 PM8240 Panel mount meter, Circularity Profile, End of Life Instructions - ENVEOLI1406023_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2b79dc673b9000465aef572237a32d122ecba9bf.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 PM8240 Panel mount meter, Environmental Disclosure, Product Environmental Profile - ENVPEP1406023EN (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45836855279920,"sku":"METSECAB10","price":387.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/e505817c80ba3bbe3de6a5f8b5d60d2b1d684907-large.png?v=1690279223"},{"product_id":"metsepm5110-power-meter-powerlogic-pm5110-modbus-up-to-15th-harmonic-1do","title":"power meter PowerLogic PM5110, modbus, up to 15th Harmonic, 1DO 33 alarms","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: power meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic PM5000\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: PM5110\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: up to the 15th harmonic\u003c\/li\u003e\n\u003cli\u003eHeight: 96 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 35-760 V AC 45...65 Hz between phases || 20-440 V AC 45...65 Hz between phase and neutral\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 64 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: UL 61010-1 || EN 50470-3 || EN 50470-1 || IEC 62053-22 || IEC 60529 || IEC 62053-24 || IEC 61557-12\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 1 digital\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 || cULus UL 61010-1\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current || voltage || frequency || power factor || energy || active and reactive power\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even\/odd or none - 2 wires 2500 V || JBUS\u003c\/li\u003e\n\u003cli\u003eFrequency Measurement Range: 45-65 Hz\u003c\/li\u003e\n\u003cli\u003eRide-Through Time: 80 ms 120 V AC typical || 100 ms 230 V AC typical || 100 ms 415 V AC typical || 50 ms 125 V DC typical\u003c\/li\u003e\n\u003cli\u003eDisplay Resolution: 128 x 128 pixels\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 0\u003c\/li\u003e\n\u003cli\u003eNet Weight: 380 g\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 50-8500 mA\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || input\/output circuit screw terminal block6 || RS485 link screw terminal block4\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...450 V AC 45...65 Hz || 100...300 V DC\u003c\/li\u003e\n\u003cli\u003eMounting Mode: flush-mounted\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: active energy +\/- 0.5 % || reactive energy +\/- 2 % || active power +\/- 0.5 % || apparent power +\/- 0.5 % || frequency +\/- 0.05 % || power factor +\/- 0.5 || current +\/- 0.5 % || voltage +\/- 0.5 % || apparent energy +\/- 0.5 % || reactive power +\/- 2 %\u003c\/li\u003e\n\u003cli\u003eMounting Support: framework\u003c\/li\u003e\n\u003cli\u003ePoles Description: 1P + N || 3P + N || 3P\u003c\/li\u003e\n\u003cli\u003eData Recording: time stamping || min\/max of instantaneous values\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 1 A || 5 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: voltage 5 MOhm) || current \u0026lt;= 0.3 mOhm)\u003c\/li\u003e\n\u003cli\u003eWidth: 96 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: monochrome graphic LCD\u003c\/li\u003e\n\u003cli\u003eDevice Application: power monitoring\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.5S active energy IEC 62053-22\u003c\/li\u003e\n\u003cli\u003eMaximum Power Consumption In Va: 10 VA 415 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1305025\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1305025\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C meter || -20-70 °C display || -25--20 °C with reduced performance) display\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: voltage dips and interruptions immunity testclass A IEC 61000-4-11 || limits for harmonic current emissionsclass A IEC 61000-3-2 || electrostatic dischargelevel 4 IEC 61000-4-2 || conducted RF disturbanceslevel 3 IEC 61000-4-6 || magnetic field at power frequencylevel 4 IEC 61000-4-8 || immunity to conducted disturbances 150 kHz...80 MHz IEC 61000-4-6 || electrical fast transient\/burst immunity test IEC 61000-4-4 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || voltage dips and interruptions immunity test IEC 61000-4-11 || conducted and radiated emissionsclass B EN 55022 || surge immunity test IEC 61000-4-5\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C non-condensing\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: display IP54 IEC 60529 || rear IP30 IEC 60529\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 6561.68 ft (2000 m) CAT III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/732a81b704023b668835c19ec2b42a141334036e.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/beda63fc1052d2518d0008d123dd28fa6d52bfa4.dxf\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/536952dd71bece5f15f9306471633646ef80c359.dxf\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d73ce5ce7a00eb75f75e1de7e0847ae1480b05e3.dwg\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/595f0251c93c0b3298b0ae8d371a9f79c6c3b880.dxf\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/85264319dfe2d9b3d07f9fcd6cedfcab2f126469.dxf\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3c4121e3634949fcd59a6414fb267bc9fc960426.dxf\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c03e49f755c763e781448de05440c4f939115e8c.dxf\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f697e890065088d16cf98c9d72e5e1546d85adab.dwg\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8e88604f6cb53bbb7a85ba05c4dec2ae9e81a13b.dwg\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/88a15d9b0a9d577e1647525e95bd34745e082f7b.stp\" target=\"_blank\"\u003ePM5110 Meter, modbus, up to 15th H, 1DO 33 alarms - METSEPM5110_3D-Simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0bd46d25458f08341ea90579b69e4fd291f4d900.dwg\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2f42c25a432baeed025c7d9e4a15b53b601251b2.dwg\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4d9e5e5224661d559a9ba040b9e5700447150c74.dwg\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ef9d01f73b0c732558280a660e091b01a41bcfed.dwg\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/11b407373deea9e6e9ad550af99a55f648952c22.stp\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_3D-simplified-ec (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c31395274dac9238491785f213d0fd28c33cb863.pdf\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/320fa136f0070e854a86e5526615b93bf2261c1d.dxf\" target=\"_blank\"\u003ePM5100 Meter, up to 15th H - 3D CAD - MCADDE0000225_2D-front (dxf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b521c1e4645ce5423e42d39d947cf03ac8e5398.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Power and Energy Meters Brochure - PowerLogic+PM5000+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a71b8a3a48f1daed421df6bc22e9a31f4986e3f.pdf\" target=\"_blank\"\u003ePowerLogic Power and Energy Meters Catalog - PowerLogic+Catalog+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/14ddc2b70ab12afb36f2f337620ce8e9fc187a9a.pdf\" target=\"_blank\"\u003eAutomation and Control Essentials Catalog 2023-EN - DIA5ED2170101EN_v7_Web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4a1e918012e8b7328aeafed6342cf192a4adff78.zip\" target=\"_blank\"\u003ePM5110_PM5310_PM5330 v2.1.3 FW - PM5110_PM5310_PM5330_v2.1.3_HW_vB1.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/dbee0f8414dc7d8e263c9743aea87bcae0a6d614.zip\" target=\"_blank\"\u003ePM51xx (PM5110,5111,) Firmware V1.5.4 and V1.6.4 and associated files - Register List, Revision History - PM51xx_1.5.4_1.6.4.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f9664a80439df3fc59852ba28059edbe7c381e6.zip\" target=\"_blank\"\u003ePM51xx (PM5110,5111,) Firmware V2.1.1 and V2.2.1 and associated files - Register List, Revision History - PM51xx_2.1.1_2.2.1.zip\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ffe816d4bb8dfd2f7585f03e86783ae220cf0d0.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Technical Datasheet - PLSED310052EN_(Web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/923741d21c82780fbe51da8918f5a2759e2bc94c.pdf\" target=\"_blank\"\u003ePM5000 series_Declaration to IEC 61557-12 - Decl+61557-12_PM5100_PM5110_PM5111_PM5310_PM5330_PM5331_PM5320_PM5340_PM5341 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2c87361be78b53b5bb5d37945452af9b820c60a7.pdf\" target=\"_blank\"\u003ePM51xx_PM53xx_CE_Certificate - PM51xx+PM53xx+CE+Certification (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8812ca689ebed9c927da34a59c72e8901ed33a10.pdf\" target=\"_blank\"\u003ePM5000 series_ UK Declaration of conformity - UK_DOC_PM5000-A12-V3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/75ec94c90d92ac634aa2b1d1e61611e88ab39c41.pdf\" target=\"_blank\"\u003ePM5000 series_EU Declaration of Conformity - ECDPM5000-V15c (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a720c522608981638b9dd9d1e0b9b4c5214d045f.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5100 series - User Manual - EAV15105-EN10 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f868631ce664ace260627edf6ab268297e02e753.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5100 series - Instruction sheet - HRB32897-11 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8690396ec045215e2c46db6ead2ffbad9d03d237.pdf\" target=\"_blank\"\u003ePowerLogic PM5000, Environmental Disclosure, Product Environmental Profile - ENVPEP1305025_V2 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5c5e34638efee6327591807916d4cf800890da2c.pdf\" target=\"_blank\"\u003ePowerLogic PM5000, PM5100, PM5300, Circularity Profile, End of Life Instructions - ENVEOLI1305025_V2 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45837204128048,"sku":"METSEPM5110","price":1142.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/07b38343be6051d7f8465f622196cebac3783f96-large.png?v=1690284456"},{"product_id":"metsepmak-powerlogic-series-mouting-adapter-for-powermeter-remote-display","title":"PowerLogic series mouting adapter for PowerMeter + Remote Display back to back","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAccessory \/ Separate Part Category: adaptation accessory\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: remote display adaptor\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic PM8000) || PowerLogic (PowerLogic ION7400) || PowerLogic (PowerLogic PM5000)\u003c\/li\u003e\n\u003cli\u003eKit Composition: 1 x ANSI 4\" adaptor || 1 x wedge adaptor || 1 x fixing nut || 4 x nut || 4 x washer || 4 x screw Philips No 2 || 2 x screw Philips No 3 || 1 x DIN rail || 1 x DIN rail support || 1 x Ethernet cable, 3 m || 1 x cable, 0.3 m || 2 x end stop || 1 x gasket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1406023EN\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1406023EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eStandards: UL 50\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b5e86fa76bd33af539565a8deca81ea14084d971.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/51d26bbb33ebc803cc076adbf77768284594814e.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power Meters eBrochure - PM8000DigitalBRUS_3000AV1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c19e99da0e0df1905086a8b3dd9d125ea3193c9a.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power and Energy Meters Brochure - PM8000+Series+Meter+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d05420c674b33c152fe8dac0456df747a07ceb88.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5RD - Instruction sheet - EAV90213-05 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/14a265cc3363928fd53fe9d225d74e214cb35afd.pdf\" target=\"_blank\"\u003ePowerLogic METSEPMAK - EAV47351-02 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/118d3e5b515ddc36be551f6828604e4716b30fd5.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 PM8240 Panel mount meter, Circularity Profile, End of Life Instructions - ENVEOLI1406023_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2b79dc673b9000465aef572237a32d122ecba9bf.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 PM8240 Panel mount meter, Environmental Disclosure, Product Environmental Profile - ENVPEP1406023EN (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45837235552560,"sku":"METSEPMAK","price":515.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/cd2feb0d3f49660773a1e1b06032665836b1cd62-large.png?v=1690285211"},{"product_id":"metsepm5330-power-meter-powerlogic-pm5330-modbus-up-to-31st-harmonic-256kb","title":"power meter PowerLogic PM5330, modbus, up to 31st Harmonic, 256KB 2DI\/2DO 35 alarms","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: power meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic PM5000\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: PM5330\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: up to the 31st harmonic\u003c\/li\u003e\n\u003cli\u003eHeight: 96 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 35-760 V AC 45...65 Hz between phases || 20-400 V AC 45...65 Hz between phase and neutral\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 64 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: UL 61010-1 || IEC 62053-22 || IEC 61557-12 || EN 50470-3 || IEC 60529 || IEC 62053-24 || EN 50470-1\u003c\/li\u003e\n\u003cli\u003eMemory Capacity: 256 kB\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 2 relay || 2 digital\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 || cULus UL 61010-1\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current || voltage || frequency || power factor || energy || active and reactive power\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even\/odd or none - 2 wires 2500 V || JBUS\u003c\/li\u003e\n\u003cli\u003eFrequency Measurement Range: 45-65 Hz\u003c\/li\u003e\n\u003cli\u003eRide-Through Time: 80 ms 120 V AC typical || 100 ms 230 V AC typical || 100 ms 415 V AC typical || 50 ms 125 V DC typical\u003c\/li\u003e\n\u003cli\u003eDisplay Resolution: 128 x 128 pixels\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 2 digital\u003c\/li\u003e\n\u003cli\u003eNet Weight: 430 g\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 5-8500 mA\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || input\/output circuit screw terminal block6 || relay output screw terminal block4 || Ethernet network RJ45 connector\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: tariff 4)\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...450 V AC 45...65 Hz || 100...300 V DC\u003c\/li\u003e\n\u003cli\u003eMounting Mode: flush-mounted\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: active energy +\/- 0.5 % || reactive energy +\/- 2 % || active power +\/- 0.5 % || apparent power +\/- 0.5 % || frequency +\/- 0.05 % || power factor +\/- 0.5 || current +\/- 0.5 % || voltage +\/- 0.5 % || apparent energy +\/- 0.5 % || reactive power +\/- 2 %\u003c\/li\u003e\n\u003cli\u003eMounting Support: framework\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P + N || 3P || 1P + N\u003c\/li\u003e\n\u003cli\u003eData Recording: maintenance logs || time stamping || alarm logs || data logs || min\/max of instantaneous values || event logs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 1 A || 5 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: voltage 5 MOhm) || current \u0026lt;= 0.3 mOhm)\u003c\/li\u003e\n\u003cli\u003eWidth: 96 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: monochrome graphic LCD\u003c\/li\u003e\n\u003cli\u003eDevice Application: power monitoring || multi-tariff\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.5S active energy IEC 62053-22\u003c\/li\u003e\n\u003cli\u003eMaximum Power Consumption In Va: 11 VA 415 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1305025\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1305025\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C meter\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: conducted and radiated emissionsclass B EN 55022 || immunity to conducted disturbances 150 kHz...80 MHzlevel 4 IEC 61000-4-6 || electrical fast transient\/burst immunity testlevel 3 IEC 61000-4-4 || radiated radio-frequency electromagnetic field immunity testlevel 4 IEC 61000-4-3 || voltage dips and interruptions immunity testclass B IEC 61000-4-11 || limits for harmonic current emissionsclass A IEC 61000-3-2 || electrostatic dischargelevel 4 IEC 61000-4-2 || conducted RF disturbanceslevel 3 IEC 61000-4-6 || magnetic field at power frequencylevel 4 IEC 61000-4-8 || immunity to conducted disturbances 150 kHz...80 MHz IEC 61000-4-6 || electrical fast transient\/burst immunity test IEC 61000-4-4 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || voltage dips and interruptions immunity test IEC 61000-4-11 || limitation of voltage changes, voltage fluctuations and flicker in low-voltage IEC 61000-3-3 || electrostatic discharge 8 kVlevel 4 IEC 61000-4-2\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C non-condensing\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: display IP54 IEC 60529 || rear IP30 IEC 60529\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 6561.68 ft (2000 m) CAT III || 9842.52 ft (3000 m) CAT II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5994e98ba2f0d8a735eb0ab177c08be63a7e7180.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/98a6f0b3b483ab1a448d34f35da17b584a0b4286.dwg\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8fdb568c975e45da9503f574169ece8436e01ec9.dxf\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a4f6dc2000c414df24119c31ca42dec5c0a37ac8.dwg\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8a270a6f105c3238dc689abce94ee9f988e2026d.dwg\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/028eda7cc7d51cdda7d670d7fa32aae4e968dc25.dwg\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e049f47fafc4298679ff920140c46628f3516fee.dxf\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9f47e7d0796783c55c14bd563c73dae6ce5e0f1b.dwg\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c105a155472a5e7d6f94b7296649e26bdb85e1c0.stp\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_3D-simplified-ec (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/247bd3a61e71295f4819063fc514693994283c76.dxf\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/91b9f04597101788ecb793cd97e00fa81b9c77dc.dxf\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/932fa02fd25f71e67b163dcb4e83a28e5ab7f200.dwg\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a482ce485f595366d7c92f0acce2221a7a802729.stp\" target=\"_blank\"\u003ePM5330 Meter, modbus, up to 31st H, 256K 2DI\/2DO 35 alarms - METSEPM5330_3D-Simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fdad3c5550708f28277fec9b68a70c6aca9b3b64.dxf\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d953df1906b8c5a5bf8258ea2d92db2d67ead205.dxf\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9a014ba0ab076bef5998ae4de2e74563ad78ec0b.dxf\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f571c5719a48a56d3ea7b46a35c51fa6b634abc4.dwg\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c7c0241e823a56959f09f7dd2a631a88aa55c02f.pdf\" target=\"_blank\"\u003ePM533x Meter, modbus, up to 31st H - 3D CAD - MCADDE0000229 (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b521c1e4645ce5423e42d39d947cf03ac8e5398.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Power and Energy Meters Brochure - PowerLogic+PM5000+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4a1e918012e8b7328aeafed6342cf192a4adff78.zip\" target=\"_blank\"\u003ePM5110_PM5310_PM5330 v2.1.3 FW - PM5110_PM5310_PM5330_v2.1.3_HW_vB1.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/24c64e376f35b595a12042cea37b07af5d9bece4.zip\" target=\"_blank\"\u003ePM53xx (PM5310,PM5320,PM5330,PM5331,PM5340,PM5341) Firmware V1.5.4 and V1.6.4 and associated files - Register List, Revision History - PM53xx_1.5.4_1.6.4.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5303640a9f9f06b58fcaca5d651cdc948263bc9c.zip\" target=\"_blank\"\u003ePM53xx (PM5310,PM5320,PM5330,PM5331,PM5340,PM5341) Firmware V2.1.1 and V2.2.1 and associated files - Register List, Revision History, Whats New - PM53xx_2.1.1_2.2.1.zip\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ffe816d4bb8dfd2f7585f03e86783ae220cf0d0.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Technical Datasheet - PLSED310052EN_(Web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8812ca689ebed9c927da34a59c72e8901ed33a10.pdf\" target=\"_blank\"\u003ePM5000 series_ UK Declaration of conformity - UK_DOC_PM5000-A12-V3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/923741d21c82780fbe51da8918f5a2759e2bc94c.pdf\" target=\"_blank\"\u003ePM5000 series_Declaration to IEC 61557-12 - Decl+61557-12_PM5100_PM5110_PM5111_PM5310_PM5330_PM5331_PM5320_PM5340_PM5341 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2c87361be78b53b5bb5d37945452af9b820c60a7.pdf\" target=\"_blank\"\u003ePM51xx_PM53xx_CE_Certificate - PM51xx+PM53xx+CE+Certification (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/75ec94c90d92ac634aa2b1d1e61611e88ab39c41.pdf\" target=\"_blank\"\u003ePM5000 series_EU Declaration of Conformity - ECDPM5000-V15c (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b512e873207a406717b7fd89377a4813428b08aa.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5300 series - Instruction sheet - HRB69887-12 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e4461d0406e168d1351546a2b71c94705465e63d.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5300 series - User Manual - EAV15107-EN10 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8690396ec045215e2c46db6ead2ffbad9d03d237.pdf\" target=\"_blank\"\u003ePowerLogic PM5000, Environmental Disclosure, Product Environmental Profile - ENVPEP1305025_V2 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5c5e34638efee6327591807916d4cf800890da2c.pdf\" target=\"_blank\"\u003ePowerLogic PM5000, PM5100, PM5300, Circularity Profile, End of Life Instructions - ENVEOLI1305025_V2 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45837244137776,"sku":"METSEPM5330","price":1637.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/4d085409d13b9dadbc2e5f988a6f3ce3809ff311-large.png?v=1690285427"},{"product_id":"metsepm5560-power-meter-powerlogic-pm5560-2-ethernet-up-to-63th-harmonic-1","title":"power meter PowerLogic PM5560, 2 ethernet, up to 63th Harmonic, 1,1MB 4DI\/2DO 52 alarms","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: power meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic PM5000\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: PM5560\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: RS485 || ETHERNET\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: up to the 63rd harmonic\u003c\/li\u003e\n\u003cli\u003eHeight: 96 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 20-400 V AC 45...65 Hz between phase and neutral || 20-828 V AC 45...65 Hz between phases\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 128 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: EN 50470-3 || IEC 61557-12 || IEC 62053-22 || IEC 62053-24 || IEC 60529 || EN 50470-1 || UL 61010-1 || ANSI C12.20\u003c\/li\u003e\n\u003cli\u003eMemory Capacity: 1.1 MB\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 2 digital\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 || cULus UL 61010-1 || BTL\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current || voltage || frequency || power factor || energy || active and reactive power\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even\/odd or none - 2 wires 2500 V || JBUS || Modbus TCP\/IP 10\/100 Mbit\/s 2500 V || Ethernet Modbus TCP\/IP daisy chain || BACnet IP || DNP3 over ethernet\u003c\/li\u003e\n\u003cli\u003eFrequency Measurement Range: 45-65 Hz\u003c\/li\u003e\n\u003cli\u003eRide-Through Time: 35 ms 120 V AC typical || 129 ms 230 V AC typical || 50 ms 125 V DC typical\u003c\/li\u003e\n\u003cli\u003eDisplay Resolution: 128 x 128 pixels\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 4 digital\u003c\/li\u003e\n\u003cli\u003eNet Weight: 450 g\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 50-10000 mA\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || RS485 link screw terminal block4 || digital input screw terminal block8 || digital output screw terminal block4 || Ethernet network RJ45 connector2\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: tariff 8)\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 100...300 V DC || 90...528 V AC 45...65 Hz\u003c\/li\u003e\n\u003cli\u003eMounting Mode: flush-mounted\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: apparent power +\/- 0.5 % || frequency +\/- 0.05 % || active energy +\/- 0.2 % || reactive energy +\/- 1 % || active power +\/- 0.2 % || voltage +\/- 0.1 % || power factor +\/- 0.005 || current +\/- 0.15 % || reactive power +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eEthernet Service: SNTP client || SNMP-Traps\u003c\/li\u003e\n\u003cli\u003eMounting Support: framework\u003c\/li\u003e\n\u003cli\u003eCommunication Gateway: Ethernet\/serial\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P + N || 3P || 1P + N\u003c\/li\u003e\n\u003cli\u003eData Recording: event logs || maintenance logs || min\/max of instantaneous values || data logs || alarm logs || time stamping\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 1 A || 5 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: voltage 5 MOhm) || current \u0026lt;= 0.3 mOhm)\u003c\/li\u003e\n\u003cli\u003eWeb Services: alarm notification by e-mail || diagnostic via predefined web pages || web server || real time viewing of data\u003c\/li\u003e\n\u003cli\u003eWidth: 96 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: Backlit LCD\u003c\/li\u003e\n\u003cli\u003eDevice Application: gateway || WAGES metering || power monitoring || multi-tariff\u003c\/li\u003e\n\u003cli\u003eMetering Type: measured neutral current || calculated ground current\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.2S active energy IEC 62053-22\u003c\/li\u003e\n\u003cli\u003eMaximum Power Consumption In Va: 10 VA 480 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1310016EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eToxic Heavy Metal Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1310016EN\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: limits for harmonic current emissionsclass A IEC 61000-3-2 || conducted RF disturbanceslevel 3 IEC 61000-4-6 || magnetic field at power frequencylevel 4 IEC 61000-4-8 || conducted and radiated emissionsclass B EN 55022 || limitation of voltage changes, voltage fluctuations and flicker in low-voltage IEC 61000-3-3 || electrostatic discharge 8 kVlevel 4 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || electrical fast transient\/burst immunity testlevel 4 IEC 61000-4-4 || surge immunity testlevel 4 IEC 61000-4-5 || voltage dips and interruptions immunity test IEC 61000-4-11\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C non-condensing\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: display IP54 IEC 60529 || rear IP30 IEC 60529\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: \u0026lt;= 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/125c14d7c54fddc0f16d86924e3ea7147a35287f.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/bd476b2a46a1f7485901664fa26a18a3ab446455.dxf\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4c512b698c3c047fb803e56ea0a4f3c15c4edfe7.dxf\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c1f8b9d0e78f1b6da5ec747f3fb8a380e104dce6.dwg\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8df29e8246afb6141b721dfaa07d3354e9c95d47.dwg\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c4f56430a6e6bac509315704881ac306e532d1fa.dwg\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4a692a7605b3432793b69fb0542feb3fdd1b8762.dxf\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a77a3b4cc9d52cc13a189f5f9a082ac28a2798a8.stp\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_3D-simplified-ec (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b7b2f3f81d611d133b8240a660d628a9c8826913.dwg\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ae4c92ed7627dc19676bc54ff01b6c1c753c4d73.dxf\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/cf8e2cc31a86e0d4d533c1496ff9418f11e1f217.dwg\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1df25b331f683ec3ea37019038ae76e446c33b36.pdf\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1cb2fe982299e4c18529a3d99427dfe37deb0f88.dxf\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4ee1270819e1173f2f50797f0844f915cd35bbf4.dxf\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ce717b8912a28e7f5d2fcd4d3e6de03b912ac80d.dwg\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7bb00464c9927eb2458f05f608c34b755b5d8c73.dwg\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/987d880fca0d7f883809391d8465001f7f44efef.dxf\" target=\"_blank\"\u003ePM5560 Meter, 2 ethernet, up to 63th H - 3D CAD - MCADDE0000232_2D-front (dxf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b521c1e4645ce5423e42d39d947cf03ac8e5398.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Power and Energy Meters Brochure - PowerLogic+PM5000+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4bcaa87f54ac6c90f05446efd9f0291c4d31ba3f.zip\" target=\"_blank\"\u003ePowerLogic PM5560 PM5563 PM5580 V4.1.8 UTv3.4 Firmware Release - PM5560_PM5563_PM5580_V4.1.8_UTv3.4_Release.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0bdabb4fd6fe12358558bc8bc1ab6fa578db8d28.zip\" target=\"_blank\"\u003ePM5560 and PM5563 V2.0.1 Firmware - PM5560_PM5563_v2.0.1.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/af67fb318ea8e3db24b5f7e02d7f53834f7c3cde.zip\" target=\"_blank\"\u003ePowerLogic PM5560 \/ PM5563 V2.7.4 Firmware Release - PM5560_PM5563_V2.7.4_Release.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/dd0467869b4ee9e5411dfa50a0e15934de3b7187.zip\" target=\"_blank\"\u003ePowerLogic PM5560 PM5563 PM5580 V4.2.1 UTv3.10 Firmware Release - PM5560_PM5563_PM5580_V4.2.1_UTv3.10_Release.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a962e7b0339cb13bc1d5fe3980856ecf4d4c0584.zip\" target=\"_blank\"\u003ePowerLogic PM5560 \/ PM5563 V2.7.7 Firmware Release - PM5560_PM5563_V2.7.7_Release.zip\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f9c01d8a5122ecbf06c250e85a48697a0878e796.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5500 \/ PM5600 \/ PM5700 series - User Manual - HRB1684301-14 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3d065c2eec18ecc0f8717caa37c8742fcec07ae8.pdf\" target=\"_blank\"\u003eWhat's new in PowerLogic PM5500 firmware version 2.3.0 - 7EN12-0294-00 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/14ddc2b70ab12afb36f2f337620ce8e9fc187a9a.pdf\" target=\"_blank\"\u003eAutomation and Control Essentials Catalog 2023-EN - DIA5ED2170101EN_v7_Web (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a71b8a3a48f1daed421df6bc22e9a31f4986e3f.pdf\" target=\"_blank\"\u003ePowerLogic Power and Energy Meters Catalog - PowerLogic+Catalog+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ffe816d4bb8dfd2f7585f03e86783ae220cf0d0.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Technical Datasheet - PLSED310052EN_(Web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a504987d75a56569c814fff26b06f77098c70c6e.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5560 \/ PM5580 \/ PM5650 - Instruction sheet - GDE41422-04 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9c1a3e84cea4f5a393650b67c0d57c540e9f8cad.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5560 Series Grounding Module - Instruction sheet - NVE30698-02 (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8812ca689ebed9c927da34a59c72e8901ed33a10.pdf\" target=\"_blank\"\u003ePM5000 series_ UK Declaration of conformity - UK_DOC_PM5000-A12-V3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d09b74bf14865e000a058577caadb7479643c467.pdf\" target=\"_blank\"\u003ePM5000 series_Declaration to IEC 61557-12 - PM55xx+IEC61557-12_PM5560_PM5563 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/75ec94c90d92ac634aa2b1d1e61611e88ab39c41.pdf\" target=\"_blank\"\u003ePM5000 series_EU Declaration of Conformity - ECDPM5000-V15c (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Hotfix\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/92e3e67015d02bbee239daec96ddd4b6f6485511.zip\" target=\"_blank\"\u003ePM5500\/5600\/5700 Series SE Driver for PME 9.0 (ENG) - PM5500_5600_5700+Series+SE+Driver+9.0.20206.01+ENG.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/42e046da4f984eb081f806c7ca945fca421a5ae7.zip\" target=\"_blank\"\u003ePM5500\/5600\/5700 Series SE Driver for PME 2020 (ENG) - PM5500_5600_5700+Series+SE+Driver+PME+2020.20205.01+ENG.zip\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0467bd9bfb3be94dc8bd23ea8ec42ca1ee5eaccb.pdf\" target=\"_blank\"\u003ePower Logic PM5500 Series Meter, Circularity Profile, End of Life Instructions - ENVEOLI1310016EN (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a52a4dd25a10e579eaa6009d6f321beb5a3e3ace.pdf\" target=\"_blank\"\u003ePower Logic PM5500 Series Meter, Environmental Disclosure, Product Environmental Profile - ENVPEP1310016_V1 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45837305610544,"sku":"METSEPM5560","price":3216.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/fbef28a2eba119973c89a815e6be8ffa2556aca2-large.png?v=1690286872"},{"product_id":"metsepm5563-power-meter-powerlogic-pm5563-2-ethernet-up-to-63th-harmonic-1","title":"power meter PowerLogic PM5563, 2 ethernet, up to 63th Harmonic, 1,1MB 4DI\/2DO 52 alarms, DIN mounted","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: power meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic PM5000\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: PM5563\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: RS485 || ETHERNET\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: up to the 63rd harmonic\u003c\/li\u003e\n\u003cli\u003eHeight: 96 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 20-400 V AC 45...65 Hz between phase and neutral || 20-828 V AC 45...65 Hz between phases\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 128 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: EN 50470-1 || IEC 60529 || IEC 62053-24 || UL 61010-1 || IEC 62053-22 || IEC 61557-12 || EN 50470-3 || ANSI C12.20\u003c\/li\u003e\n\u003cli\u003eMemory Capacity: 1.1 MB\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 2 digital\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 || cULus UL 61010-1 || BTL\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current || voltage || frequency || power factor || energy || active and reactive power\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even\/odd or none - 2 wires 2500 V || JBUS || Modbus TCP\/IP 10\/100 Mbit\/s 2500 V || Ethernet Modbus TCP\/IP daisy chain || BACnet IP || DNP3 over ethernet\u003c\/li\u003e\n\u003cli\u003eFrequency Measurement Range: 45-65 Hz\u003c\/li\u003e\n\u003cli\u003eRide-Through Time: 35 ms 120 V AC typical || 129 ms 230 V AC typical || 50 ms 125 V DC typical\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 4 digital\u003c\/li\u003e\n\u003cli\u003eNet Weight: 450 g\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 50-10000 mA\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || RS485 link screw terminal block4 || digital input screw terminal block8 || digital output screw terminal block4 || Ethernet network RJ45 connector2\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: tariff 8)\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 100...300 V DC || 90...528 V AC 45...65 Hz\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: apparent power +\/- 0.5 % || frequency +\/- 0.05 % || active energy +\/- 0.2 % || reactive energy +\/- 1 % || active power +\/- 0.2 % || voltage +\/- 0.1 % || power factor +\/- 0.005 || current +\/- 0.15 % || reactive power +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eEthernet Service: SNMP-Traps || SNTP client\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003eCommunication Gateway: Ethernet\/serial\u003c\/li\u003e\n\u003cli\u003ePoles Description: 1P + N || 3P || 3P + N\u003c\/li\u003e\n\u003cli\u003eData Recording: maintenance logs || event logs || alarm logs || time stamping || data logs || min\/max of instantaneous values\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 5 A || 1 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: voltage 5 MOhm) || current \u0026lt;= 0.3 mOhm)\u003c\/li\u003e\n\u003cli\u003eWeb Services: alarm notification by e-mail || diagnostic via predefined web pages || web server || real time viewing of data\u003c\/li\u003e\n\u003cli\u003eWidth: 96 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: Without Display\u003c\/li\u003e\n\u003cli\u003eDevice Application: power monitoring || WAGES metering || gateway || multi-tariff\u003c\/li\u003e\n\u003cli\u003eMetering Type: measured neutral current || calculated ground current\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.2S active energy IEC 62053-22\u003c\/li\u003e\n\u003cli\u003eMaximum Power Consumption In Va: 16 VA 480 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1412028EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eToxic Heavy Metal Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1412028EN\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: limits for harmonic current emissionsclass A IEC 61000-3-2 || conducted RF disturbanceslevel 3 IEC 61000-4-6 || magnetic field at power frequencylevel 4 IEC 61000-4-8 || conducted and radiated emissionsclass B EN 55022 || limitation of voltage changes, voltage fluctuations and flicker in low-voltage IEC 61000-3-3 || electrostatic discharge 8 kVlevel 4 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || electrical fast transient\/burst immunity testlevel 4 IEC 61000-4-4 || surge immunity testlevel 4 IEC 61000-4-5 || voltage dips and interruptions immunity test IEC 61000-4-11\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C non-condensing\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: display IP54 IEC 60529 || rear IP30 IEC 60529\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: \u0026lt;= 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6cb4e1bac39def675669c0d9ae86a8c915234cf3.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fdfc310cacaa341a3c359a56272256d4ed7375e6.dwg\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2eff459b7a6f0500222f16fb29c9ed50b86e25b8.dxf\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8e8c56936d05be99ad8df6c4b4e1b6e1c572211e.dwg\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/be94b85fd850ef12775f9e7bf6fb6e69fbcf988b.dxf\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/62921c0271a0ff89fb5f843e6a0f5d623b6e45f9.dxf\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c862fc68b519fc9a9cde344619c9803a5429ec07.dwg\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/15d9129665a2c36b7679e0e095856a49439e2351.dxf\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/cb52f9f8acaf8ec0439cb24d9bf9d905e8f689a5.stp\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_3D-simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5237451a613c8c2a96d99c9efe987fd86d77dfe0.dwg\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a5e2fb89679fdb582ede593134b09e2ced5d7d60.dwg\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9f75aa24e7c4eb26aeb30fd02b858f1a48947008.dxf\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4e70faa6cbd740f16d099d8af86c351ffbfb59f2.dxf\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5ef67905f56bba192e04ab2b5fc5ffe60bf82f54.pdf\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/dba763da6eb09664a1d6df6e63ed5d6e97365d76.dxf\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/422b9364dffc83bac1610e4a6a96d586bacb601a.dwg\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/210f1a6819d43c042a263e15f9748c4ffd3de89c.dwg\" target=\"_blank\"\u003ePowerlogic PM5500 - 3D CAD - MCADDE0000233_2D-right (dwg)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b521c1e4645ce5423e42d39d947cf03ac8e5398.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Power and Energy Meters Brochure - PowerLogic+PM5000+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4bcaa87f54ac6c90f05446efd9f0291c4d31ba3f.zip\" target=\"_blank\"\u003ePowerLogic PM5560 PM5563 PM5580 V4.1.8 UTv3.4 Firmware Release - PM5560_PM5563_PM5580_V4.1.8_UTv3.4_Release.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/dd0467869b4ee9e5411dfa50a0e15934de3b7187.zip\" target=\"_blank\"\u003ePowerLogic PM5560 PM5563 PM5580 V4.2.1 UTv3.10 Firmware Release - PM5560_PM5563_PM5580_V4.2.1_UTv3.10_Release.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/af67fb318ea8e3db24b5f7e02d7f53834f7c3cde.zip\" target=\"_blank\"\u003ePowerLogic PM5560 \/ PM5563 V2.7.4 Firmware Release - PM5560_PM5563_V2.7.4_Release.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a962e7b0339cb13bc1d5fe3980856ecf4d4c0584.zip\" target=\"_blank\"\u003ePowerLogic PM5560 \/ PM5563 V2.7.7 Firmware Release - PM5560_PM5563_V2.7.7_Release.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0bdabb4fd6fe12358558bc8bc1ab6fa578db8d28.zip\" target=\"_blank\"\u003ePM5560 and PM5563 V2.0.1 Firmware - PM5560_PM5563_v2.0.1.zip\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f9c01d8a5122ecbf06c250e85a48697a0878e796.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5500 \/ PM5600 \/ PM5700 series - User Manual - HRB1684301-14 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3d065c2eec18ecc0f8717caa37c8742fcec07ae8.pdf\" target=\"_blank\"\u003eWhat's new in PowerLogic PM5500 firmware version 2.3.0 - 7EN12-0294-00 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a71b8a3a48f1daed421df6bc22e9a31f4986e3f.pdf\" target=\"_blank\"\u003ePowerLogic Power and Energy Meters Catalog - PowerLogic+Catalog+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical illustration\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8168c1fb465a283b9ef264779ce5eab5c842204c.svg\" target=\"_blank\"\u003eIllustration: Dimensions Drawing for PM5563 - TI_DIM_PM5563.svg\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8b40ed6ffd82e9b549ce4b49db10bc57c5645ecd.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5CAB03_PM5CAB1_PM5CAB3_PM5CAB4_PM5CAB10 Cable Assembly - Instruction sheet - JYT98380-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9c1a3e84cea4f5a393650b67c0d57c540e9f8cad.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5560 Series Grounding Module - Instruction sheet - NVE30698-02 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c649de8d1602239a916d4d9b7a5f1e21a9d862fa.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5563 - Instruction sheet - EAV91010-05 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d05420c674b33c152fe8dac0456df747a07ceb88.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5RD - Instruction sheet - EAV90213-05 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/efe93796bc6c9e6340150624518b2616b74763fa.pdf\" target=\"_blank\"\u003ePowerLogic PM5CAB10 - NHA34756-00 (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ffe816d4bb8dfd2f7585f03e86783ae220cf0d0.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Technical Datasheet - PLSED310052EN_(Web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8812ca689ebed9c927da34a59c72e8901ed33a10.pdf\" target=\"_blank\"\u003ePM5000 series_ UK Declaration of conformity - UK_DOC_PM5000-A12-V3 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d09b74bf14865e000a058577caadb7479643c467.pdf\" target=\"_blank\"\u003ePM5000 series_Declaration to IEC 61557-12 - PM55xx+IEC61557-12_PM5560_PM5563 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/75ec94c90d92ac634aa2b1d1e61611e88ab39c41.pdf\" target=\"_blank\"\u003ePM5000 series_EU Declaration of Conformity - ECDPM5000-V15c (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Hotfix\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/92e3e67015d02bbee239daec96ddd4b6f6485511.zip\" target=\"_blank\"\u003ePM5500\/5600\/5700 Series SE Driver for PME 9.0 (ENG) - PM5500_5600_5700+Series+SE+Driver+9.0.20206.01+ENG.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/42e046da4f984eb081f806c7ca945fca421a5ae7.zip\" target=\"_blank\"\u003ePM5500\/5600\/5700 Series SE Driver for PME 2020 (ENG) - PM5500_5600_5700+Series+SE+Driver+PME+2020.20205.01+ENG.zip\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/81fda7f0a6363b5c3cf1c1557ef07af93d7e5ca2.pdf\" target=\"_blank\"\u003ePowerLogic PM5563 Transducer Meter, Circularity Profile, End of Life Instructions - ENVEOL1412028EN (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f15820c7ca7d4cd2cec116b05149b4dae40268bf.pdf\" target=\"_blank\"\u003ePowerLogic PM5563 Transducer Meter, Environmental Disclosure, Product Environmental Profile - ENVPEP1412028EN (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45837305708848,"sku":"METSEPM5563","price":2551.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/1774a1dade23261acd7aed27dd9e9953105de654-large.png?v=1690286881"},{"product_id":"metsepm89rd96-powerlogic-pm8000-89rd-remote-display-96x96mm-with-3m-cable","title":"PowerLogic PM8000 - 89RD Remote display 96x96mm, with 3m cable + mount acc","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic PM8000) || PowerLogic (PowerLogic ION7400)\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: remote display\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDisplay Type: colour TFT LCD\u003c\/li\u003e\n\u003cli\u003eDevice Application: human-machine dialogue application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInformation Displayed: energy consumption || voltage || power || harmonic distortion || frequency || current || system alarm || I\/O status\u003c\/li\u003e\n\u003cli\u003eHeight: 96 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Resolution: 320 x 240 pixels QVGA\u003c\/li\u003e\n\u003cli\u003eNet Weight: 300 g\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: Mounting Hardware || cable 3 m\u003c\/li\u003e\n\u003cli\u003eMessages Display Capacity: graphic objects (bargraph, button, light...)\u003c\/li\u003e\n\u003cli\u003eConnector Type: RJ45\u003c\/li\u003e\n\u003cli\u003eControl Type: 5 x push-button\u003c\/li\u003e\n\u003cli\u003eMounting Mode: flush-mounted\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: status LED Green) || alarm LED Red)\u003c\/li\u003e\n\u003cli\u003eMounting Support: framework remote display\u003c\/li\u003e\n\u003cli\u003eDisplay Size: 3.5 inch\u003c\/li\u003e\n\u003cli\u003eWidth: 96 mm\u003c\/li\u003e\n\u003cli\u003eProjecting Depth: 27 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1406040EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1406040EN\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Certifications: IEC\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-60 °C\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 %\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: IP54 IEC 60529\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 0...9842.52 ft (0...3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/eebc6c5d70c8979d1c1d39d3ae159dee1bd92729.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7aa0fef2a5769c819c8e60bee8929a9c161e8f56.pdf\" target=\"_blank\"\u003ePM8000-IEC62052-11 IEC62053-22 IEC62053-23 IEC61326-1 Certificate - PM8240+IEC+Report+-+First+7+Pages (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f8ab17eff0dd5807368cec2c16c2237172cc343d.pdf\" target=\"_blank\"\u003ePM8000-IEC61850 Certificate - PM8000_16-0005_DNVGL_Schneider_ION7400_PM8000_ServerEd2_Certificate (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2a95e91e59d0709326c9e6fb119b8900d497541f.pdf\" target=\"_blank\"\u003ePM8000-IEC62053-22 IEC62053-23 Certificate - PM8243+IEC+Report+-+First+6+Pages (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/97a159fa381d317c84b9f5128c92096ede7ed870.zip\" target=\"_blank\"\u003ePM8000-ECD - PM8000_ECDPM8000-MID-V6a (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d12ba526dc8eb19b263ca3ae02a90b8289699624.pdf\" target=\"_blank\"\u003ePM8000-IEC61557-12 Declaration - PM8000_IEC+61557-12-PM8000+declaration+V1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c4663d4621492fbd70a45bcdebbf083c9f6ccf67.pdf\" target=\"_blank\"\u003ePM8000-IEC61000-4-30 Class S Certificate - PM8000_CoC-15200734-01 (pdf)\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/868c614c51ecb1a84ac0d5770158bb5a0431f064.dxf\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0990d0304c8a50232313df1e96644031524ab3de.dxf\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3c09debe677d4d74b2d8d9946349fda51161df43.dwg\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1329ddd6f029c87a321efdda762e3c9355b0db6c.dwg\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5a068378e9efbd3e43f43da34747062a7ef83ff4.dwg\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4823ef1923f90b68b7eb1686b7a80b649ea999aa.dxf\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a5424de967c3fc7d558c1db7fa865ff274dfc753.dwg\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a8f95635b289d58c895b744e8c041674ff8b97b7.stp\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_3D-simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1cb2d9162e89df63354ba35f74551361006f3b16.dxf\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f68c39264e56c95cb5d2ddc16df5f791d77c4bed.dxf\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2918225dd5134ad5149fbd25a81b623c5a7b5287.dwg\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8aec514ed6bdcbf48ccb442df2a43942a99c7379.pdf\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f1919b7397aef195d7d101961ed6ed86025b6b35.dxf\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3469a89a9a9e4dc739c3f9f6c0670b8c0cecd4cf.dwg\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d8a2b98019713b3d5b12c72df6a561da2a671b14.dwg\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f41fcf786a8bcafe247bc30dcc46d3d543ce84a6.dxf\" target=\"_blank\"\u003eRemote display, color LCD, 96x96 - 3D CAD - MCADDE0000244_2D-front (dxf)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2cfb8a704fe72f43bfcaf7fbb49d31e4e4548cd2.pdf\" target=\"_blank\"\u003eION9000T Meter Handout - ION9000T+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c19e99da0e0df1905086a8b3dd9d125ea3193c9a.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power and Energy Meters Brochure - PM8000+Series+Meter+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/51d26bbb33ebc803cc076adbf77768284594814e.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power Meters eBrochure - PM8000DigitalBRUS_3000AV1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/266801e070ae85005f6c79c1c3fe7e3fa513881b.zip\" target=\"_blank\"\u003eUpgrade meter firmware to v2.2.1 - 7EN72-0203-03_UpgradeMeterFirmwarev2.2.1_TechNote (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7b6caff4aeabb62a312131c0bac93727e79afe82.chm\" target=\"_blank\"\u003eION Device Templates Reference - IONDeviceTemplateReference.chm\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4b0800a4c06e593c0828e13c4981d80869004269.zip\" target=\"_blank\"\u003eUpgrade PM89RD96 display firmware to v4.0.15 - 7EN72-0202-03_UpgradeRD96DisplayFirmwarev4.0.15_TechNote (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9b81148e5763fd70b73321efc29e0570b8fdc1cc.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series meter firmware v2.1.0 - 7EN12-0316-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ebcf73d57c9b28b6f0063388ecbf8c68c275b503.pdf\" target=\"_blank\"\u003ePM8000 series user manual - 7EN02-0336-09 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f2b8fe1b97d98c0d6560aef0822a50a5654a83f.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Firmware version 4.0.0 - supports v2.0.0 meter firmware - rmdupg_rd96_004.000.000.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5a8b82df1259b822332c607252506a3a0807058.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - 7EN72-0202-02_RD96_Display_firmware_upgrade (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/14e684bccf0d6dca26c8a260de2d3e1904103141.pdf\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Patch for affected 3.2.x displays. - 7EN72-0202-00_RD96_Display_upgrade_using_ION9000_meter (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f23748641c4143bb5b55d71f16622ea9e697fa5d.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - TechnicalNote_UpgradeMeterFirmwarev2.2.1pdf (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2ebd2857a58f74fd79889b692d3049b34d4630a8.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - 7EN72-0203-01_Upgrading_devices_to_FW_v2.1.0 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d8c2f103bb4248dc1e0b88d403352c9bccf283ad.s19\" target=\"_blank\"\u003eMETSEPM89M0024 Analog I\/O Module V001.002.000 firmware - METSEPM89M0024_AIO_V001.002.000_Release.s19\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/325cdc72c8216b1bee219a6321b9e98a3f145b5e.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - PM8000_V002.002.001.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/42eaa96168323357f9b35ad6a0db8fa81f6f28f0.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - PM8000_V002.001.000.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/69f2445f94cad0066bc81813258713ea98811f8f.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Patch for affected 3.2.x displays. - rmdupg_rd96s_001.000.000_patch.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ad48db79e630627b5a4458f653088f8ba4586711.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Firmware version 3.2.193 - Supports PM8000 \u0026amp; ION74000 v1.4.x and older meter firmware. - rmdupg_rd96.003.002.193.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/19e2655b44ab977e67808dc4301c2b1b46baef43.s19\" target=\"_blank\"\u003eMETSEPM89M2600 Digital I\/O Module V001.002.000 firmware - METSEPM89M2600_DIO_V001.002.000_Release.s19\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a5f380c1a0e8416e9e53a0979d426399779f86ca.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - TechnicalNote_UpgradePM89RD96displayFirmwarev4.0.15 (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4ab0d00a2994a188ad9f8a19c770e001c935a8ef.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Technical Datasheet - PLSED310058EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c5826106ca52ddc32a6b8e50d4eba3e5c85b165f.pdf\" target=\"_blank\"\u003ePowerLogic ION7400 Series Technical Datasheet - PLSED310113EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b6deefaafe6f06304593832056616a3cc7484e48.pdf\" target=\"_blank\"\u003ePowerLogic ION9000 Technical Datasheet - PLSED310106EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/60385fb2772030538e527c788b1ce59ca4433116.pdf\" target=\"_blank\"\u003eION7400 range - Declaration of Conformity - ECDION7400-A4-V4 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e576deb77276a509e8e6b849098a03c90f9224d5.pdf\" target=\"_blank\"\u003eION7400 Declaration of Conformity CoC-2274923-02 (Class S) - CoC-2274923-02+-+ION7400+-+Class+S (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/77e191f5bc42deade6b002c37f07a6aac7374b96.pdf\" target=\"_blank\"\u003eWhat's new in PowerLogic™ PM8000 series meter firmware v3.1.0 - 7EN12-0345-00 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a7d9e89085bf4beff63b6b14910423e6fc0c65b3.pdf\" target=\"_blank\"\u003ePowerLogic PM89RD96 remote display installation instructions - EAV47345-04 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f8afd25ee1f8a3c18fe98ecf190b7d1c64ffa31a.pdf\" target=\"_blank\"\u003ePowerLogic METSE7X4MAK ION9000 Adapter Plate Install Sheet - MFR26552_00_+Install_Sheet_Adapter_Plate_Kit (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9606df1d7d475b3013f01d72fd77d6deaa178b09.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Remote display, Circularity Profile, End of Life Instructions - ENVEOLI1406040_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6e8cbaa1c7610245b5da18972ecc9a05fdc709a7.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Remote display, Environmental Disclosure, Product Environmental Profile - ENVPEP1406040EN (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45837460635952,"sku":"METSEPM89RD96","price":1209.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/f262c8553d295c988b01977391619b6573dc3e32-large.png?v=1690290219"},{"product_id":"metsepm89m0024-powerlogic-pm8000-i-o-module-analogue-4-inputs-2-outputs","title":"PowerLogic PM8000 - I\/O Module - Analogue - 4 inputs + 2 outputs","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic PM8000) || PowerLogic (PowerLogic ION7400) || PowerLogic (PowerLogic ION9000)\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: I\/O module\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Application: optional expansion module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 90.5 mm\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 2 analog, 0-20 mA or 4-20 mA 0...10 V\u003c\/li\u003e\n\u003cli\u003eNet Weight: 140 g\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 4 analog 0...20 mA\/4...20 mA 0...30 V\u003c\/li\u003e\n\u003cli\u003eWidth: 22 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 90.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1406023EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1406023EN\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: IP30 IEC 60529\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d69fba127143894997ddd0cbf509531f536fb704.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4bbebd9abecfbc64fe95568a41bed21db1d68d3b.dxf\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0745c8c9c376ff2b3c331bba108f3cec07c22b70.dxf\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38de9be23abd37c380dec2e0a27b59356569f8f5.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a00453212ab098285aa0126212ac858f80c66eaf.dxf\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0cac77f45670f797c64b3451150059faca6081da.dwg\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8997f1941f909f24151d850196bf5678c3a6aeb8.dwg\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0b4214d39ff1bc2975af9a12c47e2d0f7f83699d.dwg\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2ec68adc0c0de11cd5c5e6a8d6d55d7c831106ac.dxf\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9c6e0e34a6fb1e676d003eda48cb0a2e1772dc90.dwg\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4a1ee99f16bc0a3bd3adb44d0ddf25a06c5f799d.dwg\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/79f72214aebc79a5c31e0f0997e113c36d46ba43.dwg\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/61d3e772b13819c743350006b03acc2f7a4223bc.dxf\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0a7cfc099809ad0a4b040824f9b924c26837bc97.dxf\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6b0b6a9d26701329a307de900817dd29643885bb.stp\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_3D-simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/08da7d9e619ad73d8b34f0f3cf8bdd8aba566159.dxf\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2900016e930e15a9ac69c8d529e69a0ae986399b.dwg\" target=\"_blank\"\u003ePowerLogic PM8000 - I\/O Module - 3D CAD - MCADDE0000242_2D-right (dwg)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2cfb8a704fe72f43bfcaf7fbb49d31e4e4548cd2.pdf\" target=\"_blank\"\u003eION9000T Meter Handout - ION9000T+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c19e99da0e0df1905086a8b3dd9d125ea3193c9a.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power and Energy Meters Brochure - PM8000+Series+Meter+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/51d26bbb33ebc803cc076adbf77768284594814e.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power Meters eBrochure - PM8000DigitalBRUS_3000AV1501 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7b6caff4aeabb62a312131c0bac93727e79afe82.chm\" target=\"_blank\"\u003eION Device Templates Reference - IONDeviceTemplateReference.chm\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ebcf73d57c9b28b6f0063388ecbf8c68c275b503.pdf\" target=\"_blank\"\u003ePM8000 series user manual - 7EN02-0336-09 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1af8552332a9a64582c57b4a9d1929d24ca2b380.pdf\" target=\"_blank\"\u003eWhat’s new in ION9000 series meter firmware v2.1.0 - 7EN12-0318-00_ION9000_Whats_New_Firmware_v2.1.0 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9b81148e5763fd70b73321efc29e0570b8fdc1cc.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series meter firmware v2.1.0 - 7EN12-0316-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/266801e070ae85005f6c79c1c3fe7e3fa513881b.zip\" target=\"_blank\"\u003eUpgrade meter firmware to v2.2.1 - 7EN72-0203-03_UpgradeMeterFirmwarev2.2.1_TechNote (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d8c2f103bb4248dc1e0b88d403352c9bccf283ad.s19\" target=\"_blank\"\u003eMETSEPM89M0024 Analog I\/O Module V001.002.000 firmware - METSEPM89M0024_AIO_V001.002.000_Release.s19\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a5f380c1a0e8416e9e53a0979d426399779f86ca.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - TechnicalNote_UpgradePM89RD96displayFirmwarev4.0.15 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/42eaa96168323357f9b35ad6a0db8fa81f6f28f0.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - PM8000_V002.001.000.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5a8b82df1259b822332c607252506a3a0807058.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - 7EN72-0202-02_RD96_Display_firmware_upgrade (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ad48db79e630627b5a4458f653088f8ba4586711.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Firmware version 3.2.193 - Supports PM8000 \u0026amp; ION74000 v1.4.x and older meter firmware. - rmdupg_rd96.003.002.193.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2ebd2857a58f74fd79889b692d3049b34d4630a8.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - 7EN72-0203-01_Upgrading_devices_to_FW_v2.1.0 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/19e2655b44ab977e67808dc4301c2b1b46baef43.s19\" target=\"_blank\"\u003eMETSEPM89M2600 Digital I\/O Module V001.002.000 firmware - METSEPM89M2600_DIO_V001.002.000_Release.s19\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/325cdc72c8216b1bee219a6321b9e98a3f145b5e.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - PM8000_V002.002.001.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f23748641c4143bb5b55d71f16622ea9e697fa5d.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - TechnicalNote_UpgradeMeterFirmwarev2.2.1pdf (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/69f2445f94cad0066bc81813258713ea98811f8f.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Patch for affected 3.2.x displays. - rmdupg_rd96s_001.000.000_patch.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/14e684bccf0d6dca26c8a260de2d3e1904103141.pdf\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Patch for affected 3.2.x displays. - 7EN72-0202-00_RD96_Display_upgrade_using_ION9000_meter (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f2b8fe1b97d98c0d6560aef0822a50a5654a83f.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Firmware version 4.0.0 - supports v2.0.0 meter firmware - rmdupg_rd96_004.000.000.bin\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b6deefaafe6f06304593832056616a3cc7484e48.pdf\" target=\"_blank\"\u003ePowerLogic ION9000 Technical Datasheet - PLSED310106EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c5826106ca52ddc32a6b8e50d4eba3e5c85b165f.pdf\" target=\"_blank\"\u003ePowerLogic ION7400 Series Technical Datasheet - PLSED310113EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4ab0d00a2994a188ad9f8a19c770e001c935a8ef.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Technical Datasheet - PLSED310058EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e576deb77276a509e8e6b849098a03c90f9224d5.pdf\" target=\"_blank\"\u003eION7400 Declaration of Conformity CoC-2274923-02 (Class S) - CoC-2274923-02+-+ION7400+-+Class+S (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/60385fb2772030538e527c788b1ce59ca4433116.pdf\" target=\"_blank\"\u003eION7400 range - Declaration of Conformity - ECDION7400-A4-V4 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b5bf317a9bd4789a543a62744889c08754c855b0.pdf\" target=\"_blank\"\u003eION7400 range (MID versions) - Declaration of Conformity - ECDION7400-MID-A4-V4 (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/77e191f5bc42deade6b002c37f07a6aac7374b96.pdf\" target=\"_blank\"\u003eWhat's new in PowerLogic™ PM8000 series meter firmware v3.1.0 - 7EN12-0345-00 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2798f2f0d21919f51942bf3d627499229a81b2be.pdf\" target=\"_blank\"\u003ePowerLogic Analog I\/O option module - MFR58208_00_Install_Sheet+Analog_IO_Option_Module (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/118d3e5b515ddc36be551f6828604e4716b30fd5.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 PM8240 Panel mount meter, Circularity Profile, End of Life Instructions - ENVEOLI1406023_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2b79dc673b9000465aef572237a32d122ecba9bf.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 PM8240 Panel mount meter, Environmental Disclosure, Product Environmental Profile - ENVPEP1406023EN (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45837600293168,"sku":"METSEPM89M0024","price":2024.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/59b51be0370c1badcb0c761246dda04dd9c285c2-large.png?v=1690292052"},{"product_id":"metsepm8243-powerlogic-pm8000-pm8243-din-rail-mount-meter-intermediate","title":"PowerLogic PM8000 - PM8243 DIN rail mount meter - intermediate metering","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: power meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic PM8000\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: PM8243\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Network Type: IPv6 (internet protocol)\u003c\/li\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: ETHERNET || screw terminal block RS485\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: EN 50160 2010 compliance report || IEEE 519 2014 compliance report || IEC 61000-4-30 class S power quality measurement || up to the 63rd harmonic || harmonic distortion || waveform capture || voltage sag and swell detection || programmablity (logic and math functions) || IEC 62586 power quality monitoring\u003c\/li\u003e\n\u003cli\u003eHeight: 90.5 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 61557-12 || IEC 62052-11 || IEC 62053-22 || IEC 62053-24 || IEEE 1588 || IEC 62586-2 || IEC 61326-1\u003c\/li\u003e\n\u003cli\u003eMemory Capacity: 512 MB\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 1 pulse\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE || cULus || N998\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current || voltage || frequency || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU 115 kbauds - 2-wire || ION 115 kbauds - 2-wire || DNP3 || IEC 61850 || Modbus TCP\/IP || Ethernet Modbus TCP\/IP daisy chain 10\/100 Mbit\/s || RSTP 801.1d 2004\u003c\/li\u003e\n\u003cli\u003eFrequency Measurement Range: 42-69 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Service: SMTP e-mail notification || DHCP || RSTP support || NTP time synchronization || PTP time synchronization\u003c\/li\u003e\n\u003cli\u003ePower Consumption In Va: 18 VA 415 V AC\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 3 digital 30 V AC || 3 digital 60 V DC\u003c\/li\u003e\n\u003cli\u003eNet Weight: 528 g\u003c\/li\u003e\n\u003cli\u003eDepth: 90.8 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 50-10000 mA\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: voltage || current || frequency || power || energy consumption || harmonic distortion\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...415 V AC 45...65 Hz +\/- 10 % || 110...415 V DC +\/- 10 %\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: current +\/- 0.1 % || voltage +\/- 0.1 % || active energy +\/- 0.2 %\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003ePoles Description: 1P + N || 3P + N || 3P\u003c\/li\u003e\n\u003cli\u003eData Recording: harmonics logs || sag and swell logs || GPS synchronisation || time stamping || data logs || trending\/forecasting || waveform logs || alarm logs || sequence of event recording || min\/max of instantaneous values || event logs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 1 A || 10 A || 5 A\u003c\/li\u003e\n\u003cli\u003eCybersecurity: password protection || port hardening || enable\/disable communication ports || robust security logs || Syslog protocol support\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: III400-690 V conforming to IEC 61010-1:ed. 3 || III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: voltage 5 MOhm) || current 0.3 mOhm)\u003c\/li\u003e\n\u003cli\u003eWeb Services: customizable home page || file upload\/download via FTP || file upload\/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server\u003c\/li\u003e\n\u003cli\u003eWidth: 90.5 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: Without Display\u003c\/li\u003e\n\u003cli\u003eDevice Application: WAGES metering || power monitoring\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 current IEC 61557-12\u003c\/li\u003e\n\u003cli\u003eInstallation Category: III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1406022EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1406022EN\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: electrostatic discharge IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || electrical fast transient\/burst immunity test IEC 61000-4-4 || surge immunity test IEC 61000-4-5 || conducted RF disturbances IEC 61000-4-6 || magnetic field at power frequency IEC 61000-4-8 || voltage dips and interruptions immunity test IEC 61000-4-11 || immunity to impulse waves IEC 61000-4-12 || conducted and radiated emissions EN 55022 || conducted and radiated emissions EN 55011 || conducted and radiated emissions FCC part 15 || conducted and radiated emissions ICES-003 || conducted RF disturbances 2...150 Hz) CLC\/TR 50579 || surge withstand IEEE C37.90.1\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 %\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: IP30 IEC 60529\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/49b5cd322e818712821d0e2a32373b8b52d8b98b.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/97a159fa381d317c84b9f5128c92096ede7ed870.zip\" target=\"_blank\"\u003ePM8000-ECD - PM8000_ECDPM8000-MID-V6a (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7aa0fef2a5769c819c8e60bee8929a9c161e8f56.pdf\" target=\"_blank\"\u003ePM8000-IEC62052-11 IEC62053-22 IEC62053-23 IEC61326-1 Certificate - PM8240+IEC+Report+-+First+7+Pages (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2a95e91e59d0709326c9e6fb119b8900d497541f.pdf\" target=\"_blank\"\u003ePM8000-IEC62053-22 IEC62053-23 Certificate - PM8243+IEC+Report+-+First+6+Pages (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d12ba526dc8eb19b263ca3ae02a90b8289699624.pdf\" target=\"_blank\"\u003ePM8000-IEC61557-12 Declaration - PM8000_IEC+61557-12-PM8000+declaration+V1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c4663d4621492fbd70a45bcdebbf083c9f6ccf67.pdf\" target=\"_blank\"\u003ePM8000-IEC61000-4-30 Class S Certificate - PM8000_CoC-15200734-01 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f8ab17eff0dd5807368cec2c16c2237172cc343d.pdf\" target=\"_blank\"\u003ePM8000-IEC61850 Certificate - PM8000_16-0005_DNVGL_Schneider_ION7400_PM8000_ServerEd2_Certificate (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4b8754f5ed665096939954f5df92569e075427bd.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series firmware v1.3.1 - 7EN12-0301-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0ddbbb37139aad92717f3e1eadfce8a693805b5b.pdf\" target=\"_blank\"\u003eWhat’s new for Power and Energy Monitoring Systems — November 2019 - 7EN12-0326-00_WhatsNew_Nov2019 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7b6caff4aeabb62a312131c0bac93727e79afe82.chm\" target=\"_blank\"\u003eION Device Templates Reference - IONDeviceTemplateReference.chm\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fe38e7385320af28905725b668f9d0e4bc65c0ee.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series firmware v1.4.1 - 7EN12-0312-00_WhatsNew_PM8000v1.4.1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5d5b7827602687e5322c345fab28ac37f457ccf6.pdf\" target=\"_blank\"\u003eIEC 61000-4-30 compliance and ION meters - 7EN72–0185–13_4-30ComplianceIONMeters (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9b81148e5763fd70b73321efc29e0570b8fdc1cc.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series meter firmware v2.1.0 - 7EN12-0316-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ebcf73d57c9b28b6f0063388ecbf8c68c275b503.pdf\" target=\"_blank\"\u003ePM8000 series user manual - 7EN02-0336-09 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/266801e070ae85005f6c79c1c3fe7e3fa513881b.zip\" target=\"_blank\"\u003eUpgrade meter firmware to v2.2.1 - 7EN72-0203-03_UpgradeMeterFirmwarev2.2.1_TechNote (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4b0800a4c06e593c0828e13c4981d80869004269.zip\" target=\"_blank\"\u003eUpgrade PM89RD96 display firmware to v4.0.15 - 7EN72-0202-03_UpgradeRD96DisplayFirmwarev4.0.15_TechNote (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/51d26bbb33ebc803cc076adbf77768284594814e.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power Meters eBrochure - PM8000DigitalBRUS_3000AV1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c19e99da0e0df1905086a8b3dd9d125ea3193c9a.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power and Energy Meters Brochure - PM8000+Series+Meter+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8bedc25f292fc5ccad1330635204e2a446c10319.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ff209446aa695206a0e2a6345c746002856d6ad0.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6f91b77ffaffbd6a8fcd0ded5c8276a09bad8edb.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e412f6963d80486726e154e56a560fb3d5e7ded7.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1d26fdf73ac27353f4654dc460a58dd74ab9e14f.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c5740b50367c59365856c9fd74bf9362751fec52.stp\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_3D-simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e886f32ec992b558479b419e29ccf34fd656a89f.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6f6e522df5bf65bef0a9049eea12aa67e34b6bb6.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/051c172ebf30a8cf9ada9cb1fcf9859d9c3c73c7.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5fbc08feaece9347425e6308a8977df417c89bc3.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ac6142a9f9c53d965d4588ec0fefd0b88f960939.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0c66c3058f4f3b7780878981353a7ad222c10a7a.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/46996fdbf94575806001fe3c3e9870ac4746ed25.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/845c1fec1690e66c4d7f1e844fc2a0aa6d4b93e1.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d80c35a5e1477f5cd58c2477e472c80560711457.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/252852c9cd94b259f51c63f03c08aa1a01e88b36.pdf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter 3D - Simplified - 3D CAD - MCADDE0000240 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2ebd2857a58f74fd79889b692d3049b34d4630a8.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - 7EN72-0203-01_Upgrading_devices_to_FW_v2.1.0 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/325cdc72c8216b1bee219a6321b9e98a3f145b5e.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - PM8000_V002.002.001.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/19e2655b44ab977e67808dc4301c2b1b46baef43.s19\" target=\"_blank\"\u003eMETSEPM89M2600 Digital I\/O Module V001.002.000 firmware - METSEPM89M2600_DIO_V001.002.000_Release.s19\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/42eaa96168323357f9b35ad6a0db8fa81f6f28f0.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - PM8000_V002.001.000.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/14e684bccf0d6dca26c8a260de2d3e1904103141.pdf\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Patch for affected 3.2.x displays. - 7EN72-0202-00_RD96_Display_upgrade_using_ION9000_meter (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f23748641c4143bb5b55d71f16622ea9e697fa5d.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - TechnicalNote_UpgradeMeterFirmwarev2.2.1pdf (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ad48db79e630627b5a4458f653088f8ba4586711.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Firmware version 3.2.193 - Supports PM8000 \u0026amp; ION74000 v1.4.x and older meter firmware. - rmdupg_rd96.003.002.193.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f2b8fe1b97d98c0d6560aef0822a50a5654a83f.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Firmware version 4.0.0 - supports v2.0.0 meter firmware - rmdupg_rd96_004.000.000.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/69f2445f94cad0066bc81813258713ea98811f8f.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Patch for affected 3.2.x displays. - rmdupg_rd96s_001.000.000_patch.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a5f380c1a0e8416e9e53a0979d426399779f86ca.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - TechnicalNote_UpgradePM89RD96displayFirmwarev4.0.15 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5a8b82df1259b822332c607252506a3a0807058.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - 7EN72-0202-02_RD96_Display_firmware_upgrade (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d8c2f103bb4248dc1e0b88d403352c9bccf283ad.s19\" target=\"_blank\"\u003eMETSEPM89M0024 Analog I\/O Module V001.002.000 firmware - METSEPM89M0024_AIO_V001.002.000_Release.s19\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e93af04829377e92b03e08f04126106040ea7e13.pdf\" target=\"_blank\"\u003eUK Declaration of Conformity - UKDOCPM8000-A6-V2 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fa24cd70cafaf15978a65a25782bcb6affe8d1e5.pdf\" target=\"_blank\"\u003ePowerLogic PM8243 - EAV47344-03 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2798f2f0d21919f51942bf3d627499229a81b2be.pdf\" target=\"_blank\"\u003ePowerLogic Analog I\/O option module - MFR58208_00_Install_Sheet+Analog_IO_Option_Module (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/82fd40849462e81d3e66054103483f871c2e6007.pdf\" target=\"_blank\"\u003ePowerLogic™ METSEPM89M2600 - EAV47347_02_Digital_IO_Option_Module_Install_Sheet (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a7d9e89085bf4beff63b6b14910423e6fc0c65b3.pdf\" target=\"_blank\"\u003ePowerLogic PM89RD96 remote display installation instructions - EAV47345-04 (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4ab0d00a2994a188ad9f8a19c770e001c935a8ef.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Technical Datasheet - PLSED310058EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ee3146c7e8a87b01e6b65db3094adaa32d69b036.pdf\" target=\"_blank\"\u003eKnown issues: PM8000 series firmware version v1.2.14 and v1.2.15 - 7EN42-0119-00 (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/77e191f5bc42deade6b002c37f07a6aac7374b96.pdf\" target=\"_blank\"\u003eWhat's new in PowerLogic™ PM8000 series meter firmware v3.1.0 - 7EN12-0345-00 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/49a10e50e497c2a688e83971c9e6698f0c9f4d6d.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 PM8243 DIN rail mount meter, Environmental Disclosure, Product Environmental Profile - ENVPEP1406022EN (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/9Mw0wNCXfmI\"\u003eEnabling \u0026amp; Disabling PowerLogic ION Power Meter Web Interface | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Ld_E4gGMVjk\"\u003eConfiguring External Pulse Module to Perform Energy Reset on PM8000 | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/NtwT8nC7dbo\"\u003eUpgrading Firmware on PowerLogic Gateways via FTP Command Prompt | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/7QP2l709UL0\"\u003ePerforming a Master Reset of PowerLogic PM8000 Power Meter | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45837823279408,"sku":"METSEPM8243","price":7654.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/24fa473798c598f9bb6b7e91952f783b3305060f-large.png?v=1690294802"},{"product_id":"metsepm8240-powerlogic-pm8000-pm8240-panel-mount-meter-intermediate","title":"PowerLogic PM8000 - PM8240 Panel mount meter - intermediate metering","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: power meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic PM8000\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: PM8240\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Network Type: IPv6 (internet protocol)\u003c\/li\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: ETHERNET || screw terminal block RS485\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: EN 50160 2010 compliance report || IEEE 519 2014 compliance report || IEC 61000-4-30 class S power quality measurement || up to the 63rd harmonic || harmonic distortion || waveform capture || voltage sag and swell detection || programmablity (logic and math functions) || IEC 62586 power quality monitoring\u003c\/li\u003e\n\u003cli\u003eHeight: 96 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 61557-12 || IEC 62052-11 || IEC 62053-24 || IEC 62053-22 || IEEE 1588 || IEC 62586-2 || IEC 61326-1\u003c\/li\u003e\n\u003cli\u003eMemory Capacity: 512 MB\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 1 pulse\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE || cULus || N998\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current || voltage || frequency || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU 115 kbauds - 2-wire || ION 115 kbauds - 2-wire || DNP3 || IEC 61850 || Modbus TCP\/IP || Ethernet Modbus TCP\/IP daisy chain 10\/100 Mbit\/s || RSTP 801.1d 2004\u003c\/li\u003e\n\u003cli\u003eFrequency Measurement Range: 42-69 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Service: SMTP e-mail notification || RSTP support || NTP time synchronization || DHCP || PTP time synchronization\u003c\/li\u003e\n\u003cli\u003ePower Consumption In Va: 18 VA 415 V AC\u003c\/li\u003e\n\u003cli\u003eDisplay Resolution: 320 x 240 pixels QVGA\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 3 digital 30 V AC || 3 digital 60 V DC\u003c\/li\u003e\n\u003cli\u003eNet Weight: 581 g\u003c\/li\u003e\n\u003cli\u003eDepth: 77.5 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 50-10000 mA\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: voltage || current || frequency || power || energy consumption || harmonic distortion\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...415 V AC 45...65 Hz +\/- 10 % || 110...415 V DC +\/- 10 %\u003c\/li\u003e\n\u003cli\u003eMounting Mode: flush-mounted\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: current +\/- 0.1 % || voltage +\/- 0.1 % || active energy +\/- 0.2 %\u003c\/li\u003e\n\u003cli\u003eMounting Support: framework\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P + N || 3P || 1P + N\u003c\/li\u003e\n\u003cli\u003eData Recording: min\/max of instantaneous values || waveform logs || sequence of event recording || time stamping || alarm logs || trending\/forecasting || sag and swell logs || harmonics logs || GPS synchronisation || data logs || event logs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 1 A || 5 A || 10 A\u003c\/li\u003e\n\u003cli\u003eCybersecurity: enable\/disable communication ports || password protection || Syslog protocol support || robust security logs || port hardening\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: III400-690 V conforming to IEC 61010-1:ed. 3 || III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: voltage 5 MOhm) || current 0.3 mOhm)\u003c\/li\u003e\n\u003cli\u003eWeb Services: customizable home page || file upload\/download via FTP || file upload\/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server\u003c\/li\u003e\n\u003cli\u003eWidth: 96 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: colour TFT LCD\u003c\/li\u003e\n\u003cli\u003eDevice Application: power monitoring || WAGES metering\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 current IEC 61557-12\u003c\/li\u003e\n\u003cli\u003eInstallation Category: III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1406023EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1406023EN\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: electrostatic discharge IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || electrical fast transient\/burst immunity test IEC 61000-4-4 || surge immunity test IEC 61000-4-5 || conducted RF disturbances IEC 61000-4-6 || magnetic field at power frequency IEC 61000-4-8 || voltage dips and interruptions immunity test IEC 61000-4-11 || immunity to impulse waves IEC 61000-4-12 || conducted and radiated emissions EN 55022 || conducted and radiated emissions EN 55011 || conducted and radiated emissions FCC part 15 || conducted and radiated emissions ICES-003 || conducted RF disturbances 2...150 Hz) CLC\/TR 50579 || surge withstand IEEE C37.90.1\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 %\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: front IP54 IEC 60529 || body IP30 IEC 60529\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/30afc1bf661c05bd6072b537835361f768c70b80.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7aa0fef2a5769c819c8e60bee8929a9c161e8f56.pdf\" target=\"_blank\"\u003ePM8000-IEC62052-11 IEC62053-22 IEC62053-23 IEC61326-1 Certificate - PM8240+IEC+Report+-+First+7+Pages (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/97a159fa381d317c84b9f5128c92096ede7ed870.zip\" target=\"_blank\"\u003ePM8000-ECD - PM8000_ECDPM8000-MID-V6a (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c4663d4621492fbd70a45bcdebbf083c9f6ccf67.pdf\" target=\"_blank\"\u003ePM8000-IEC61000-4-30 Class S Certificate - PM8000_CoC-15200734-01 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2a95e91e59d0709326c9e6fb119b8900d497541f.pdf\" target=\"_blank\"\u003ePM8000-IEC62053-22 IEC62053-23 Certificate - PM8243+IEC+Report+-+First+6+Pages (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f8ab17eff0dd5807368cec2c16c2237172cc343d.pdf\" target=\"_blank\"\u003ePM8000-IEC61850 Certificate - PM8000_16-0005_DNVGL_Schneider_ION7400_PM8000_ServerEd2_Certificate (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d12ba526dc8eb19b263ca3ae02a90b8289699624.pdf\" target=\"_blank\"\u003ePM8000-IEC61557-12 Declaration - PM8000_IEC+61557-12-PM8000+declaration+V1 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7b6caff4aeabb62a312131c0bac93727e79afe82.chm\" target=\"_blank\"\u003eION Device Templates Reference - IONDeviceTemplateReference.chm\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5d5b7827602687e5322c345fab28ac37f457ccf6.pdf\" target=\"_blank\"\u003eIEC 61000-4-30 compliance and ION meters - 7EN72–0185–13_4-30ComplianceIONMeters (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/266801e070ae85005f6c79c1c3fe7e3fa513881b.zip\" target=\"_blank\"\u003eUpgrade meter firmware to v2.2.1 - 7EN72-0203-03_UpgradeMeterFirmwarev2.2.1_TechNote (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0a2773bd0c015650ab27d461e8703a96c804efbb.pdf\" target=\"_blank\"\u003eION Reference - EN - 7EN02-0290-12 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0ddbbb37139aad92717f3e1eadfce8a693805b5b.pdf\" target=\"_blank\"\u003eWhat’s new for Power and Energy Monitoring Systems — November 2019 - 7EN12-0326-00_WhatsNew_Nov2019 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ebcf73d57c9b28b6f0063388ecbf8c68c275b503.pdf\" target=\"_blank\"\u003ePM8000 series user manual - 7EN02-0336-09 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4b8754f5ed665096939954f5df92569e075427bd.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series firmware v1.3.1 - 7EN12-0301-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9b81148e5763fd70b73321efc29e0570b8fdc1cc.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series meter firmware v2.1.0 - 7EN12-0316-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fe38e7385320af28905725b668f9d0e4bc65c0ee.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series firmware v1.4.1 - 7EN12-0312-00_WhatsNew_PM8000v1.4.1 (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c19e99da0e0df1905086a8b3dd9d125ea3193c9a.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power and Energy Meters Brochure - PM8000+Series+Meter+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/51d26bbb33ebc803cc076adbf77768284594814e.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power Meters eBrochure - PM8000DigitalBRUS_3000AV1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7f59ba3a9c30023a27c8325c26f9ededed4954f4.stp\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_3D-simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a17e2ca80cf932e75c784bc57f436e0958396b6c.dwg\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/94f8b578594fc20c3feae3cb0bedc94a2ed6dbe7.dwg\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e580649fd1e4b0fe867eb584efc5e216be28b676.dxf\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/af6090fe4ecd6a1de705c02ff14a0df862bafea7.dxf\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/cb8d6c8b07885e001cd1df2dfac2a9acbe4c91d6.dwg\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a926ff141508dc46d587aeffcec166c4a72bd2a2.dxf\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9d9375f8280ba91f95c464f827caf1314500fefc.dwg\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5719837294d1d72f8c01401ddc02e762392bb193.dxf\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/64122214a8a3fdb0538275d4c84181e6b1fdde92.dwg\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8c26cdfe5f89ada79553ebd0d58506177b555597.dwg\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c429eb8ee0dca7c21df3013d72b9d50c1d32f67e.dxf\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6cf23d5f7a64051bf3d5dbc53f9236f546372832.pdf\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/cafe0495d08c508409d897a7a90af34b79d4fce7.dwg\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/99e04b62d4a0a0b67ca5d387061aaf92c2ca9d62.dxf\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9e7378cbe15592b9555548716cc7e4902b9f679a.dxf\" target=\"_blank\"\u003ePM8000 Panel Mount Meter 3D - Simplified - 3D CAD - MCADDE0000239_2D-top (dxf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4ab0d00a2994a188ad9f8a19c770e001c935a8ef.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Technical Datasheet - PLSED310058EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1fdf822fb7fe25a562199caf0845a5fc0ec072ec.pdf\" target=\"_blank\"\u003eION Setup Release Notes - RelNotes (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a71b8a3a48f1daed421df6bc22e9a31f4986e3f.pdf\" target=\"_blank\"\u003ePowerLogic Power and Energy Meters Catalog - PowerLogic+Catalog+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/77e191f5bc42deade6b002c37f07a6aac7374b96.pdf\" target=\"_blank\"\u003eWhat's new in PowerLogic™ PM8000 series meter firmware v3.1.0 - 7EN12-0345-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f9df3c228d787fd0bd43bd40c47d7a22bf8ea914.exe\" target=\"_blank\"\u003eION Setup Latest Release - IONSetup+v3.2.23123.01.exe\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/325cdc72c8216b1bee219a6321b9e98a3f145b5e.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - PM8000_V002.002.001.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a5f380c1a0e8416e9e53a0979d426399779f86ca.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - TechnicalNote_UpgradePM89RD96displayFirmwarev4.0.15 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5a8b82df1259b822332c607252506a3a0807058.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - 7EN72-0202-02_RD96_Display_firmware_upgrade (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/42eaa96168323357f9b35ad6a0db8fa81f6f28f0.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - PM8000_V002.001.000.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2ebd2857a58f74fd79889b692d3049b34d4630a8.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - 7EN72-0203-01_Upgrading_devices_to_FW_v2.1.0 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f23748641c4143bb5b55d71f16622ea9e697fa5d.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - TechnicalNote_UpgradeMeterFirmwarev2.2.1pdf (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f2b8fe1b97d98c0d6560aef0822a50a5654a83f.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Firmware version 4.0.0 - supports v2.0.0 meter firmware - rmdupg_rd96_004.000.000.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d8c2f103bb4248dc1e0b88d403352c9bccf283ad.s19\" target=\"_blank\"\u003eMETSEPM89M0024 Analog I\/O Module V001.002.000 firmware - METSEPM89M0024_AIO_V001.002.000_Release.s19\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ad48db79e630627b5a4458f653088f8ba4586711.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Firmware version 3.2.193 - Supports PM8000 \u0026amp; ION74000 v1.4.x and older meter firmware. - rmdupg_rd96.003.002.193.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/69f2445f94cad0066bc81813258713ea98811f8f.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Patch for affected 3.2.x displays. - rmdupg_rd96s_001.000.000_patch.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/14e684bccf0d6dca26c8a260de2d3e1904103141.pdf\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Patch for affected 3.2.x displays. - 7EN72-0202-00_RD96_Display_upgrade_using_ION9000_meter (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/19e2655b44ab977e67808dc4301c2b1b46baef43.s19\" target=\"_blank\"\u003eMETSEPM89M2600 Digital I\/O Module V001.002.000 firmware - METSEPM89M2600_DIO_V001.002.000_Release.s19\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e93af04829377e92b03e08f04126106040ea7e13.pdf\" target=\"_blank\"\u003eUK Declaration of Conformity - UKDOCPM8000-A6-V2 (pdf)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ee3146c7e8a87b01e6b65db3094adaa32d69b036.pdf\" target=\"_blank\"\u003eKnown issues: PM8000 series firmware version v1.2.14 and v1.2.15 - 7EN42-0119-00 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2798f2f0d21919f51942bf3d627499229a81b2be.pdf\" target=\"_blank\"\u003ePowerLogic Analog I\/O option module - MFR58208_00_Install_Sheet+Analog_IO_Option_Module (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/82fd40849462e81d3e66054103483f871c2e6007.pdf\" target=\"_blank\"\u003ePowerLogic™ METSEPM89M2600 - EAV47347_02_Digital_IO_Option_Module_Install_Sheet (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6e0fc8622cfeae2d9313b75a71443b4083a1b784.pdf\" target=\"_blank\"\u003ePowerLogic PM8210 \/ PM8240 \/ PM8280 \/ PM82403 \/ PM82404 installation guide - EAV47343-04 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/118d3e5b515ddc36be551f6828604e4716b30fd5.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 PM8240 Panel mount meter, Circularity Profile, End of Life Instructions - ENVEOLI1406023_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2b79dc673b9000465aef572237a32d122ecba9bf.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 PM8240 Panel mount meter, Environmental Disclosure, Product Environmental Profile - ENVPEP1406023EN (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/9Mw0wNCXfmI\"\u003eEnabling \u0026amp; Disabling PowerLogic ION Power Meter Web Interface | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/NtwT8nC7dbo\"\u003eUpgrading Firmware on PowerLogic Gateways via FTP Command Prompt | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/7QP2l709UL0\"\u003ePerforming a Master Reset of PowerLogic PM8000 Power Meter | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Ld_E4gGMVjk\"\u003eConfiguring External Pulse Module to Perform Energy Reset on PM8000 | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45837823312176,"sku":"METSEPM8240","price":8375.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/2512534a597a2d9f83b17cbc154bccd8f0115b4a-large.png?v=1690294804"},{"product_id":"metsepm8244-powerlogic-pm8000-pm8244-din-rail-mount-meter-remote-display","title":"PowerLogic PM8000 - PM8244 DIN rail mount meter + Remote display - int. metering","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: power meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic PM8000\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: PM8244\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Network Type: IPv6 (internet protocol)\u003c\/li\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: ETHERNET || screw terminal block RS485\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: EN 50160 2010 compliance report || IEEE 519 2014 compliance report || IEC 61000-4-30 class S power quality measurement || up to the 63rd harmonic || harmonic distortion || waveform capture || voltage sag and swell detection || programmablity (logic and math functions) || IEC 62586 power quality monitoring\u003c\/li\u003e\n\u003cli\u003eHeight: 90.5 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 62053-22 || IEC 62053-24 || IEC 62052-11 || IEC 61557-12 || IEEE 1588 || IEC 62586-2 || IEC 61326-1\u003c\/li\u003e\n\u003cli\u003eMemory Capacity: 512 MB\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 1 pulse\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE || cULus || N998\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current || voltage || frequency || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU 115 kbauds - 2-wire || ION 115 kbauds - 2-wire || DNP3 || IEC 61850 || Modbus TCP\/IP || Ethernet Modbus TCP\/IP daisy chain 10\/100 Mbit\/s || RSTP 801.1d 2004\u003c\/li\u003e\n\u003cli\u003eFrequency Measurement Range: 42-69 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Service: SMTP e-mail notification || RSTP support || NTP time synchronization || DHCP || PTP time synchronization\u003c\/li\u003e\n\u003cli\u003ePower Consumption In Va: 18 VA 415 V AC\u003c\/li\u003e\n\u003cli\u003eDisplay Resolution: 320 x 240 pixels QVGA\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 3 digital 30 V AC || 3 digital 60 V DC\u003c\/li\u003e\n\u003cli\u003eNet Weight: 528 g\u003c\/li\u003e\n\u003cli\u003eDepth: 90.8 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 50-10000 mA\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: voltage || current || frequency || power || energy consumption || harmonic distortion\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...415 V AC 45...65 Hz +\/- 10 % || 110...415 V DC +\/- 10 %\u003c\/li\u003e\n\u003cli\u003eMounting Mode: flush-mounted || clip-on\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: current +\/- 0.1 % || voltage +\/- 0.1 % || active energy +\/- 0.2 %\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail meter device || framework remote display\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P || 1P + N || 3P + N\u003c\/li\u003e\n\u003cli\u003eData Recording: sequence of event recording || event logs || min\/max of instantaneous values || harmonics logs || alarm logs || GPS synchronisation || waveform logs || data logs || time stamping || trending\/forecasting || sag and swell logs\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: remote display\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 10 A || 5 A || 1 A\u003c\/li\u003e\n\u003cli\u003eCybersecurity: password protection || Syslog protocol support || port hardening || robust security logs || enable\/disable communication ports\u003c\/li\u003e\n\u003cli\u003eIsolation Voltage: III400-690 V conforming to IEC 61010-1:ed. 3 || III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: voltage 5 MOhm) || current 0.3 mOhm)\u003c\/li\u003e\n\u003cli\u003eWeb Services: customizable home page || file upload\/download via FTP || file upload\/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server\u003c\/li\u003e\n\u003cli\u003eWidth: 90.5 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: remote LCD display\u003c\/li\u003e\n\u003cli\u003eDevice Application: WAGES metering || power monitoring\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 current IEC 61557-12\u003c\/li\u003e\n\u003cli\u003eInstallation Category: III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1406022EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1406022EN\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: electrostatic discharge IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || electrical fast transient\/burst immunity test IEC 61000-4-4 || surge immunity test IEC 61000-4-5 || conducted RF disturbances IEC 61000-4-6 || magnetic field at power frequency IEC 61000-4-8 || voltage dips and interruptions immunity test IEC 61000-4-11 || immunity to impulse waves IEC 61000-4-12 || conducted and radiated emissions EN 55022 || conducted and radiated emissions EN 55011 || conducted and radiated emissions FCC part 15 || conducted and radiated emissions ICES-003 || conducted RF disturbances 2...150 Hz) CLC\/TR 50579 || surge withstand IEEE C37.90.1\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 %\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: IP30 IEC 60529\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/485e57dfb1ded9d04caf20ba6c9a548ce0827911.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7aa0fef2a5769c819c8e60bee8929a9c161e8f56.pdf\" target=\"_blank\"\u003ePM8000-IEC62052-11 IEC62053-22 IEC62053-23 IEC61326-1 Certificate - PM8240+IEC+Report+-+First+7+Pages (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d12ba526dc8eb19b263ca3ae02a90b8289699624.pdf\" target=\"_blank\"\u003ePM8000-IEC61557-12 Declaration - PM8000_IEC+61557-12-PM8000+declaration+V1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2a95e91e59d0709326c9e6fb119b8900d497541f.pdf\" target=\"_blank\"\u003ePM8000-IEC62053-22 IEC62053-23 Certificate - PM8243+IEC+Report+-+First+6+Pages (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c4663d4621492fbd70a45bcdebbf083c9f6ccf67.pdf\" target=\"_blank\"\u003ePM8000-IEC61000-4-30 Class S Certificate - PM8000_CoC-15200734-01 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/97a159fa381d317c84b9f5128c92096ede7ed870.zip\" target=\"_blank\"\u003ePM8000-ECD - PM8000_ECDPM8000-MID-V6a (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f8ab17eff0dd5807368cec2c16c2237172cc343d.pdf\" target=\"_blank\"\u003ePM8000-IEC61850 Certificate - PM8000_16-0005_DNVGL_Schneider_ION7400_PM8000_ServerEd2_Certificate (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27690c500b60eb32fb9132fa50b4fd93d72b5928.pdf\" target=\"_blank\"\u003ePowerLogic: Top 8 Benefits Brochure - Top+8+Benefits+of+PowerLogic (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f0a8f622465b1e9997852a52043ae7c0574abab.pdf\" target=\"_blank\"\u003eEcoStruxure Power Energy Usage Performance eBrochure - 998-20406240_US_NEMA (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c19e99da0e0df1905086a8b3dd9d125ea3193c9a.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power and Energy Meters Brochure - PM8000+Series+Meter+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d8298d94a55cff06e79a1cf4e362f2a7ed81f6.pdf\" target=\"_blank\"\u003eSquare D Model 6 Intelligent Motor Control Centers Brochure - 8998BR0001 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f48d9481e794a4ac8450efb229ec2f4362b581e8.pdf\" target=\"_blank\"\u003eEcoStruxure Power Microgrid Solutions eBrochure - 998-20406245_US_NEMA+(1) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/51d26bbb33ebc803cc076adbf77768284594814e.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Series Power Meters eBrochure - PM8000DigitalBRUS_3000AV1501 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7b6caff4aeabb62a312131c0bac93727e79afe82.chm\" target=\"_blank\"\u003eION Device Templates Reference - IONDeviceTemplateReference.chm\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/266801e070ae85005f6c79c1c3fe7e3fa513881b.zip\" target=\"_blank\"\u003eUpgrade meter firmware to v2.2.1 - 7EN72-0203-03_UpgradeMeterFirmwarev2.2.1_TechNote (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0ddbbb37139aad92717f3e1eadfce8a693805b5b.pdf\" target=\"_blank\"\u003eWhat’s new for Power and Energy Monitoring Systems — November 2019 - 7EN12-0326-00_WhatsNew_Nov2019 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4b8754f5ed665096939954f5df92569e075427bd.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series firmware v1.3.1 - 7EN12-0301-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ebcf73d57c9b28b6f0063388ecbf8c68c275b503.pdf\" target=\"_blank\"\u003ePM8000 series user manual - 7EN02-0336-09 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9b81148e5763fd70b73321efc29e0570b8fdc1cc.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series meter firmware v2.1.0 - 7EN12-0316-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fe38e7385320af28905725b668f9d0e4bc65c0ee.pdf\" target=\"_blank\"\u003eWhat’s new in PM8000 series firmware v1.4.1 - 7EN12-0312-00_WhatsNew_PM8000v1.4.1 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a71b8a3a48f1daed421df6bc22e9a31f4986e3f.pdf\" target=\"_blank\"\u003ePowerLogic Power and Energy Meters Catalog - PowerLogic+Catalog+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/51349afedcb6813a0ecbad5a8dae8852a26ee719.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7c1b4681106ad0e56431007c228cd4e6eeee6873.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c518f091e2056e077386e0bffd8a261b67926286.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1b957eb3e1db958121c945e077c26277e7e2eb74.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47de3a557373ffa8afa88cc0dba60b92b646a071.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0063de23424da159e6aedd79b9e9c596a6b2a381.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/65271f42f0c6578892f75c8c940178a192adb6b7.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1ce03e74e071e4efe86daa97ef5083ce51418eb6.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/bc6368557eb5e8f98fb61f4071d6036a8e50a5aa.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/403469f5b37e33084a6cb30989f6768da7b3894c.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d407c934273aec1a51f752757fc325ef5e9db7d2.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6b22475ecd4d8bacf53628d53342376bc6e5ad37.pdf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c59e436a39dfafe93340dafa2241bc581e357e74.dwg\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/11779b68c6df5fd33aaea09b1ab32d82d07ac953.stp\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_3D-simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2f017d78eaacb384e3768b25eb4b48ce0b0a5e42.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b434abe179ecbe2b80372516730b4c889de28ebb.dxf\" target=\"_blank\"\u003ePM8000 DIN Rail Mount Meter + Remote Display 3D - Simplified - 3D CAD - MCADDE0000241_2D-bottom (dxf)\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/19e2655b44ab977e67808dc4301c2b1b46baef43.s19\" target=\"_blank\"\u003eMETSEPM89M2600 Digital I\/O Module V001.002.000 firmware - METSEPM89M2600_DIO_V001.002.000_Release.s19\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d8c2f103bb4248dc1e0b88d403352c9bccf283ad.s19\" target=\"_blank\"\u003eMETSEPM89M0024 Analog I\/O Module V001.002.000 firmware - METSEPM89M0024_AIO_V001.002.000_Release.s19\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5a8b82df1259b822332c607252506a3a0807058.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - 7EN72-0202-02_RD96_Display_firmware_upgrade (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a5f380c1a0e8416e9e53a0979d426399779f86ca.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - TechnicalNote_UpgradePM89RD96displayFirmwarev4.0.15 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/69f2445f94cad0066bc81813258713ea98811f8f.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Patch for affected 3.2.x displays. - rmdupg_rd96s_001.000.000_patch.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8f2b8fe1b97d98c0d6560aef0822a50a5654a83f.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Firmware version 4.0.0 - supports v2.0.0 meter firmware - rmdupg_rd96_004.000.000.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f23748641c4143bb5b55d71f16622ea9e697fa5d.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - TechnicalNote_UpgradeMeterFirmwarev2.2.1pdf (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ad48db79e630627b5a4458f653088f8ba4586711.bin\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Firmware version 3.2.193 - Supports PM8000 \u0026amp; ION74000 v1.4.x and older meter firmware. - rmdupg_rd96.003.002.193.bin\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/14e684bccf0d6dca26c8a260de2d3e1904103141.pdf\" target=\"_blank\"\u003ePowerLogic PM89RD96 Display OS Package Patch for affected 3.2.x displays. - 7EN72-0202-00_RD96_Display_upgrade_using_ION9000_meter (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/42eaa96168323357f9b35ad6a0db8fa81f6f28f0.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - PM8000_V002.001.000.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2ebd2857a58f74fd79889b692d3049b34d4630a8.zip\" target=\"_blank\"\u003ePM8000 V002.001.000 (v 2.1.0) Firmware and Associated Files (Meter Template, Modbus Map document, SNMP MIB, Web pages) - 7EN72-0203-01_Upgrading_devices_to_FW_v2.1.0 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/325cdc72c8216b1bee219a6321b9e98a3f145b5e.zip\" target=\"_blank\"\u003ePM8000 v2.2.1 Firmware and Associated Files - PM8000_V002.002.001.zip\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e93af04829377e92b03e08f04126106040ea7e13.pdf\" target=\"_blank\"\u003eUK Declaration of Conformity - UKDOCPM8000-A6-V2 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fa24cd70cafaf15978a65a25782bcb6affe8d1e5.pdf\" target=\"_blank\"\u003ePowerLogic PM8243 - EAV47344-03 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a7d9e89085bf4beff63b6b14910423e6fc0c65b3.pdf\" target=\"_blank\"\u003ePowerLogic PM89RD96 remote display installation instructions - EAV47345-04 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2798f2f0d21919f51942bf3d627499229a81b2be.pdf\" target=\"_blank\"\u003ePowerLogic Analog I\/O option module - MFR58208_00_Install_Sheet+Analog_IO_Option_Module (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4ab0d00a2994a188ad9f8a19c770e001c935a8ef.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 Technical Datasheet - PLSED310058EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ee3146c7e8a87b01e6b65db3094adaa32d69b036.pdf\" target=\"_blank\"\u003eKnown issues: PM8000 series firmware version v1.2.14 and v1.2.15 - 7EN42-0119-00 (pdf)\u003c\/a\u003e\u003ch4\u003eSoftware - Release\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/77e191f5bc42deade6b002c37f07a6aac7374b96.pdf\" target=\"_blank\"\u003eWhat's new in PowerLogic™ PM8000 series meter firmware v3.1.0 - 7EN12-0345-00 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ffc01bc0b12842f43a366d2cf640be1a77344350.pdf\" target=\"_blank\"\u003ePowerLogic PM8000 PM8244, Circularity Profile, End of Life Instructions - ENVEOLI1406022EN (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/NtwT8nC7dbo\"\u003eUpgrading Firmware on PowerLogic Gateways via FTP Command Prompt | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/7QP2l709UL0\"\u003ePerforming a Master Reset of PowerLogic PM8000 Power Meter | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Ld_E4gGMVjk\"\u003eConfiguring External Pulse Module to Perform Energy Reset on PM8000 | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/9Mw0wNCXfmI\"\u003eEnabling \u0026amp; Disabling PowerLogic ION Power Meter Web Interface | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45837823443248,"sku":"METSEPM8244","price":8763.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/860a365d9d30e4301403287cbdd07bd2289351be-large.png?v=1690294808"},{"product_id":"cbl020-cable-ribbon-120-in-bcm","title":"Cable, Ribbon, 120 in, BCM","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: PowerLogic\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: ribbon cable\u003c\/li\u003e\n\u003cli\u003eLength: 3 m\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: CBL\u003c\/li\u003e\n\u003cli\u003eType Of Cable: flat\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Destination: BCPM\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7e5bc23b1e0473f99a45e2bdb1e8c03ac5b460ae.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843632128304,"sku":"CBL020","price":77.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/9108b61839cab7cf499f210b2d935f45efbd98e5-large_c0c1db3d-7e52-4f85-ba66-dfd7cc5a0a2c.png?v=1690373418"},{"product_id":"cbl021-cable-ribbon-240-in-bcm","title":"Cable, Ribbon, 240 in, BCM","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: PowerLogic\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: ribbon cable\u003c\/li\u003e\n\u003cli\u003eLength: 6 m\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: CBL\u003c\/li\u003e\n\u003cli\u003eType Of Cable: flat\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Destination: BCPM\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d3201cc3378918a4a98c04dfe6238a9f62694a91.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843632259376,"sku":"CBL021","price":155.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/9108b61839cab7cf499f210b2d935f45efbd98e5-large.png?v=1690373421"},{"product_id":"cbl022-round-ribbon-cable-set-of-1-for-bcpm-length-1-2-m","title":"Round Ribbon Cable - set of 1 - for BCPM - length 1.2 m","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: PowerLogic\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: ribbon cable\u003c\/li\u003e\n\u003cli\u003eLength: 1.2 m\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: CBL\u003c\/li\u003e\n\u003cli\u003eType Of Cable: round\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Destination: BCPM\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b4104ed8b5bea0850beae728b8ca63e6a2f79f49.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843632292144,"sku":"CBL022","price":82.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/b76892faed1356401c9b7b202658530b86044270-large_e74e1189-9be3-4bae-9c1c-d199ba67ffcb.png?v=1690373423"},{"product_id":"cbl023-round-ribbon-cable-50-x-26-awg-10-ft-3m","title":"Round ribbon cable, 50 x 26 AWG, 10 ft (3m).","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: PowerLogic\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: ribbon cable\u003c\/li\u003e\n\u003cli\u003eLength: 3 m\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: CBL\u003c\/li\u003e\n\u003cli\u003eType Of Cable: round\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Destination: BCPM\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eToxic Heavy Metal Free: Yes\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6f81260b314595c26fc0286821f31bdfa7a7ac98.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843633340720,"sku":"CBL023","price":216.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/b76892faed1356401c9b7b202658530b86044270-large.png?v=1690373425"},{"product_id":"cbl016-ribbon-cable-for-4-ft-1-2m","title":"Ribbon cable for , 4 ft. (1.2m)","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: PowerLogic\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: ribbon cable\u003c\/li\u003e\n\u003cli\u003eLength: 1.2 m\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: CBL\u003c\/li\u003e\n\u003cli\u003eType Of Cable: flat\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Destination: BCPM\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7f7d9d0e38e3a953087c24703281d6e9fd48d3ce.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843633373488,"sku":"CBL016","price":48.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/9108b61839cab7cf499f210b2d935f45efbd98e5-large_a608912f-1585-4d93-ad5d-b2237a15819a.png?v=1690373426"},{"product_id":"cbl008-cable-ribbon-18-in-bcm","title":"Cable, Ribbon, 18 In, BCM","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: PowerLogic\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: ribbon cable\u003c\/li\u003e\n\u003cli\u003eLength: 0.5 m\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: CBL\u003c\/li\u003e\n\u003cli\u003eType Of Cable: flat\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Destination: BCPM\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a68ffeda6dae50f612542d28b5ab0963e7bedba7.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843633570096,"sku":"CBL008","price":41.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/9108b61839cab7cf499f210b2d935f45efbd98e5-large_3042622c-63a7-4273-947e-4492a0052695.png?v=1690373431"},{"product_id":"metsepm5563rd-power-meter-powerlogic-pm5563-2-ethernet-up-to-63th-harmonic","title":"power meter PowerLogic PM5563, 2 ethernet, up to 63th Harmonic, 1,1MB 4DI\/2DO 52 alarms, with remote display","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: power meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic PM5000\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: PM5563\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: RS485 || ETHERNET\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: up to the 63rd harmonic\u003c\/li\u003e\n\u003cli\u003eHeight: 96 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 20-400 V AC 45...65 Hz between phase and neutral || 20-828 V AC 45...65 Hz between phases\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 128 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: EN 50470-3 || EN 50470-1 || IEC 62053-22 || IEC 60529 || UL 61010-1 || IEC 62053-24 || IEC 61557-12 || ANSI C12.20\u003c\/li\u003e\n\u003cli\u003eMemory Capacity: 1.1 MB\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 2 digital\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 || cULus UL 61010-1 || BTL\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current || voltage || frequency || power factor || energy || active and reactive power\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even\/odd or none - 2 wires 2500 V || JBUS || Modbus TCP\/IP 10\/100 Mbit\/s 2500 V || Ethernet Modbus TCP\/IP daisy chain || BACnet IP || DNP3 over ethernet\u003c\/li\u003e\n\u003cli\u003eFrequency Measurement Range: 45-65 Hz\u003c\/li\u003e\n\u003cli\u003eRide-Through Time: 35 ms 120 V AC typical || 129 ms 230 V AC typical || 50 ms 125 V DC typical\u003c\/li\u003e\n\u003cli\u003eDisplay Resolution: 128 x 128 pixels\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 4 digital\u003c\/li\u003e\n\u003cli\u003eNet Weight: 450 g\u003c\/li\u003e\n\u003cli\u003eDepth: 72 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 50-10000 mA\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || RS485 link screw terminal block4 || digital input screw terminal block8 || digital output screw terminal block4 || Ethernet network RJ45 connector2\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: tariff 8)\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 100...300 V DC || 90...528 V AC 45...65 Hz\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: apparent power +\/- 0.5 % || frequency +\/- 0.05 % || active energy +\/- 0.2 % || reactive energy +\/- 1 % || active power +\/- 0.2 % || voltage +\/- 0.1 % || power factor +\/- 0.005 || current +\/- 0.15 % || reactive power +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eEthernet Service: SNTP client || SNMP-Traps\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003eCommunication Gateway: Ethernet\/serial\u003c\/li\u003e\n\u003cli\u003ePoles Description: 1P + N || 3P || 3P + N\u003c\/li\u003e\n\u003cli\u003eData Recording: time stamping || data logs || maintenance logs || event logs || alarm logs || min\/max of instantaneous values\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 1 A || 5 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: voltage 5 MOhm) || current \u0026lt;= 0.3 mOhm)\u003c\/li\u003e\n\u003cli\u003eWeb Services: diagnostic via predefined web pages || real time viewing of data || web server || alarm notification by e-mail\u003c\/li\u003e\n\u003cli\u003eWidth: 96 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: remote LCD display\u003c\/li\u003e\n\u003cli\u003eDevice Application: gateway || power monitoring || WAGES metering || multi-tariff\u003c\/li\u003e\n\u003cli\u003eMetering Type: measured neutral current || calculated ground current\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.2S active energy IEC 62053-22\u003c\/li\u003e\n\u003cli\u003eMaximum Power Consumption In Va: 16 VA 480 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1412028EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eToxic Heavy Metal Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1412028EN\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-70 °C\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: limits for harmonic current emissionsclass A IEC 61000-3-2 || conducted RF disturbanceslevel 3 IEC 61000-4-6 || magnetic field at power frequencylevel 4 IEC 61000-4-8 || conducted and radiated emissionsclass B EN 55022 || limitation of voltage changes, voltage fluctuations and flicker in low-voltage IEC 61000-3-3 || electrostatic discharge 8 kVlevel 4 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test IEC 61000-4-3 || electrical fast transient\/burst immunity testlevel 4 IEC 61000-4-4 || surge immunity testlevel 4 IEC 61000-4-5 || voltage dips and interruptions immunity test IEC 61000-4-11\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C non-condensing\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: display IP54 IEC 60529 || rear IP30 IEC 60529\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: \u0026lt;= 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/979badf0c3fbe322d4479d243014f24b894310ae.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/df35b4bad8b7caeddf44a309317fea86504fb0a7.dwg\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e25f061759995f75d0848b6df029a4940fe57afc.dwg\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/37f27a37b894cb2d884dd1b9b988fb7c13368fca.dxf\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/112f46007b9b9d94cba2bc1500417fe29def6f30.dxf\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ef3b2abdc46cd046e64cf39f28a5a54af663a492.stp\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_3D-simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/78dcc4ee4c0608d788bc434d54d99193f924cf37.dxf\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d72e43d182772f52e54e4cb318dc80cd68bb8d39.dxf\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7150f0336e3d7f458ac04ce19d90803fd466fefd.dwg\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/faf198c5db9ce38c8e91df3c50648ad3a71f42ce.dxf\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2f2eacc65f121b3f0c356322ee25f955a94124c7.dwg\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ffe67e4a68aafa307a55963e98ef257c046c183e.dwg\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/bcc69534bd2cedf56a2e8c2efd0c4484ef970daf.dwg\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c80253e7ae6625af244047d4369dda8a355048aa.dxf\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9f5615f5266a56173a1bcd8e9fe01148adcda232.dxf\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4675ba313901824bba8e62d48b3b3c857c858142.dwg\" target=\"_blank\"\u003ePM5500 INTEGRATED - 3D CAD - MCADDE0000234_2D-front (dwg)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f97a9aa3fcf58930497e32bbab7286059e3e266d.pdf\" target=\"_blank\"\u003eMedium Voltage Products ANSI Panorama Brochure - 998-20791722_GMA-US_MV-ANSI-Panorama (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/538d75468b518c4f17ca808e5b50b6e6e0615264.pdf\" target=\"_blank\"\u003eSmart Systems for Communicating Electrical Distribution Brochure - 1700BR1501 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b521c1e4645ce5423e42d39d947cf03ac8e5398.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Power and Energy Meters Brochure - PowerLogic+PM5000+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eFirmware\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/dd0467869b4ee9e5411dfa50a0e15934de3b7187.zip\" target=\"_blank\"\u003ePowerLogic PM5560 PM5563 PM5580 V4.2.1 UTv3.10 Firmware Release - PM5560_PM5563_PM5580_V4.2.1_UTv3.10_Release.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0bdabb4fd6fe12358558bc8bc1ab6fa578db8d28.zip\" target=\"_blank\"\u003ePM5560 and PM5563 V2.0.1 Firmware - PM5560_PM5563_v2.0.1.zip\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4bcaa87f54ac6c90f05446efd9f0291c4d31ba3f.zip\" target=\"_blank\"\u003ePowerLogic PM5560 PM5563 PM5580 V4.1.8 UTv3.4 Firmware Release - PM5560_PM5563_PM5580_V4.1.8_UTv3.4_Release.zip\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7a71b8a3a48f1daed421df6bc22e9a31f4986e3f.pdf\" target=\"_blank\"\u003ePowerLogic Power and Energy Meters Catalog - PowerLogic+Catalog+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f9c01d8a5122ecbf06c250e85a48697a0878e796.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5500 \/ PM5600 \/ PM5700 series - User Manual - HRB1684301-14 (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical illustration\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8168c1fb465a283b9ef264779ce5eab5c842204c.svg\" target=\"_blank\"\u003eIllustration: Dimensions Drawing for PM5563 - TI_DIM_PM5563.svg\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ffe816d4bb8dfd2f7585f03e86783ae220cf0d0.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Technical Datasheet - PLSED310052EN_(Web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d05420c674b33c152fe8dac0456df747a07ceb88.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5RD - Instruction sheet - EAV90213-05 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9c1a3e84cea4f5a393650b67c0d57c540e9f8cad.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5560 Series Grounding Module - Instruction sheet - NVE30698-02 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8b40ed6ffd82e9b549ce4b49db10bc57c5645ecd.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5CAB03_PM5CAB1_PM5CAB3_PM5CAB4_PM5CAB10 Cable Assembly - Instruction sheet - JYT98380-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c649de8d1602239a916d4d9b7a5f1e21a9d862fa.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5563 - Instruction sheet - EAV91010-05 (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/75ec94c90d92ac634aa2b1d1e61611e88ab39c41.pdf\" target=\"_blank\"\u003ePM5000 series_EU Declaration of Conformity - ECDPM5000-V15c (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8812ca689ebed9c927da34a59c72e8901ed33a10.pdf\" target=\"_blank\"\u003ePM5000 series_ UK Declaration of conformity - UK_DOC_PM5000-A12-V3 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/81fda7f0a6363b5c3cf1c1557ef07af93d7e5ca2.pdf\" target=\"_blank\"\u003ePowerLogic PM5563 Transducer Meter, Circularity Profile, End of Life Instructions - ENVEOL1412028EN (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f15820c7ca7d4cd2cec116b05149b4dae40268bf.pdf\" target=\"_blank\"\u003ePowerLogic PM5563 Transducer Meter, Environmental Disclosure, Product Environmental Profile - ENVPEP1412028EN (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843692945712,"sku":"METSEPM5563RD","price":3884.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/33ce31aec8ea54afbcbea3afe17857e92d1693e9-large_496eafe8-1fa5-4bad-a338-fb4a7d775847.png?v=1690373780"},{"product_id":"metsepm5cab10-power-logic-pm5000-cable-for-remote-display-5rd-for-pm556x","title":"Power Logic PM5000 - cable for remote display 5RD for PM556x - 10 m","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAccessory \/ Separate Part Category: communication accessory\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: display cable\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic PM5000)\u003c\/li\u003e\n\u003cli\u003eCable Length: 10 m\u003c\/li\u003e\n\u003cli\u003eAccessory \/ Separate Part Destination: remote display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1412028EN\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1412028EN\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2ca78bacd870b05c3b08b71e8986f523646d7b00.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/efe93796bc6c9e6340150624518b2616b74763fa.pdf\" target=\"_blank\"\u003ePowerLogic PM5CAB10 - NHA34756-00 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8b40ed6ffd82e9b549ce4b49db10bc57c5645ecd.pdf\" target=\"_blank\"\u003ePowerLogic™ PM5CAB03_PM5CAB1_PM5CAB3_PM5CAB4_PM5CAB10 Cable Assembly - Instruction sheet - JYT98380-00 (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ffe816d4bb8dfd2f7585f03e86783ae220cf0d0.pdf\" target=\"_blank\"\u003ePowerLogic PM5000 Series Technical Datasheet - PLSED310052EN_(Web) (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/81fda7f0a6363b5c3cf1c1557ef07af93d7e5ca2.pdf\" target=\"_blank\"\u003ePowerLogic PM5563 Transducer Meter, Circularity Profile, End of Life Instructions - ENVEOL1412028EN (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f15820c7ca7d4cd2cec116b05149b4dae40268bf.pdf\" target=\"_blank\"\u003ePowerLogic PM5563 Transducer Meter, Environmental Disclosure, Product Environmental Profile - ENVPEP1412028EN (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843694649648,"sku":"METSEPM5CAB10","price":212.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/618b7ecb4fca2294b69c0472004164afe68ccd58-large_e424ea66-4957-4826-89da-5a391937b96f.png?v=1690373800"},{"product_id":"metseem3555-powerlogic-em3500-din-rail-meter-modbus-4-quadrant-current","title":"PowerLogic EM3500 DIN rail meter - Modbus 4 quadrant - current transformer","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic EM3500\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: EM3555\u003c\/li\u003e\n\u003cli\u003eMetering Type: peak demand power PM, QM, SM || current I1, I2, I3, Iavg || active, reactive, apparent energy (signed, four quadrant) || demand power P, Q, S || voltage U21, U32, U13, V1, V2, V3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: screw terminal block RS485\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 90...347 V AC 50\/60 Hz between phase and neutral UL || 156...600 V AC 50\/60 Hz between phases UL || 90...300 V AC 50\/60 Hz between phase and neutral CE || 125...300 V DC\u003c\/li\u003e\n\u003cli\u003eStandards: CSA C22.2 No 14-05 || UL 508 || IEC 61010-1\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 1 alarm output || 1 pulse\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003ePower Consumption In Va: 5-5 VA 347 V AC between phase and neutral) || 5-5 VA 600 V AC between phases)\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010 || cULus UL 508\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: active and reactive power total || active and reactive power per phase || apparent power total || apparent power per phase || power factor total || power factor per phase || peak demand power || current || voltage || frequency\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU 1200…38400 bps - 2-wire\u003c\/li\u003e\n\u003cli\u003eCommunication Service: total cumulated active energy || total cumulated energy\u003c\/li\u003e\n\u003cli\u003eRide-Through Time: 100 ms 120 V AC\u003c\/li\u003e\n\u003cli\u003eDisplay Digits: 5\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: instantaneous and demand values || lifetime energy production\u003c\/li\u003e\n\u003cli\u003eTamperproof Of Settings: protected by access code\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 5-32000 A\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: status and alert || communication with system || input\/output status || error || Tx activity || Rx activity || instant power per usage\u003c\/li\u003e\n\u003cli\u003eFunction Available: external synchronisation to communication || fixed or rolling block\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on || by screws\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: Red LED threshold reached || Green flashing LED output signal\u003c\/li\u003e\n\u003cli\u003ePower Consumption In W: 3 W 300-300 V\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: power +\/- 0.2 % || energy +\/- 0.2 %\u003c\/li\u003e\n\u003cli\u003eTechnology Type: electronic\u003c\/li\u003e\n\u003cli\u003eBuffer Size: 16-bit 10\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P + N\u003c\/li\u003e\n\u003cli\u003eData Recording: energy consumption logs || time stamping\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: split core current transducer 0.333 V or 1 V\u003c\/li\u003e\n\u003cli\u003eDisplay Type: Backlit LCD\u003c\/li\u003e\n\u003cli\u003eDevice Application: partial meter || sub billing\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.2S power IEC 62053-22 || class 0.2S energy IEC 62053-22 || class 0.2S power ANSI C12.20 || class 0.2S energy ANSI C12.20\u003c\/li\u003e\n\u003cli\u003eRated Voltage: 90-347 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -30-70 °C\u003c\/li\u003e\n\u003cli\u003eHeight: 91 mm\u003c\/li\u003e\n\u003cli\u003e9 Mm Pitches: 12\u003c\/li\u003e\n\u003cli\u003eColor: dark grey\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 %\u003c\/li\u003e\n\u003cli\u003eWidth: 107 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 59 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/dd216f1d1261255d5d37416d49d965706a504a1a.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/bf0be01f351baa6f67348ae0f6d4d7ac6580c75e.pdf\" target=\"_blank\"\u003ePowerLogic EM3500 series Technical Datasheet - PLSED310037EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efa143c0c5263fb1977125b93a4b249b6a4b311.pdf\" target=\"_blank\"\u003eEM35xx Series Compact Power and Energy Meter Instruction Sheet - EM35xx_quick_Z206079-0F (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843816710448,"sku":"METSEEM3555","price":1306.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/23e83226e803e1b127ffbd24b675f8ad8cc22553-large_c386c387-bc36-4813-8163-ed18fabf8380.png?v=1690375731"},{"product_id":"p850eb0-p850-digital-i-o-expander-module-8-digit-i-4-0-20ma-4-c-o-for","title":"P850 digital I\/O expander module - 8 digit I - 4(0,20mA) + 4(C) O - for ION8650","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: PowerLogic\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: I\/O expansion module\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: P850E\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNumber Of Outputs: 4 form C relay output || 4 analog 0...20 mA\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: without cable\u003c\/li\u003e\n\u003cli\u003eProduct Compatibility: ION8650\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 8 digital\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0b810edfbd3062d874564f6ef4b2b3ef8789b3f3.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2e78b2712c7ddbb7d1e1f71487c92b918755bb27.pdf\" target=\"_blank\"\u003ePowerLogic ION8600 I\/O Expander Installation Guide - 70052-0112-11 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e38e18d54479835bc48b648062baa78e7a9771a5.pdf\" target=\"_blank\"\u003ePowerLogic IO\/Expander for ION8600 - Installation Guide - PowerLogic+IO+Expander+Installation+Manual (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845343338800,"sku":"P850EB0","price":2924.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/a0213eefae87b9012d5660590ece709a52d78a6a-large.png?v=1690379665"},{"product_id":"lvct20202s-lvct-200a-0-333-v-output-solid-core-ct-25-mm","title":"LVCT 200A - 0.333 V output - solid core CT - Ã˜=25 mm","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eProduct Destination: BCPMCS || EM4200 || EM4900\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: cable 1.8 m600 V\u003c\/li\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic BCPMSC) BCPMSCA multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCB multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCE multi-circuit energy meter || PowerLogic (PowerLogic EM4200) EM4235 energy meter || PowerLogic (PowerLogic EM4200) EM4236 energy meter || PowerLogic (PowerLogic EM4900) EM4904 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4908 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4914 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4928 multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eAccessory \/ Separate Part Category: measurement accessory\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 0.333 V\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 200 A\u003c\/li\u003e\n\u003cli\u003eCurrent Transformer Type: A type closed toroid\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: current transformer\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: LVCT\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eMeasurement Accuracy: +\/- 0.5 % 5...120 %\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eToxic Heavy Metal Free: Yes\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -50-105 °C\u003c\/li\u003e\n\u003cli\u003eWidth: 59 mm\u003c\/li\u003e\n\u003cli\u003eHeight: diameter 25 mm || external 59 mm\u003c\/li\u003e\n\u003cli\u003eClimatic Withstand: relative humidity 95 %\u003c\/li\u003e\n\u003cli\u003eDepth: 18 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/866c60e9cf88d4a4cf8997adccb9b6e1b0c85c3c.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c2a250d86b97e6b7b89284c0a2a0e8c0016f1303.pdf\" target=\"_blank\"\u003eEnergy Meter Kit Handout - Energy+Meter+Kit+2pg+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38569afb3de012bba3b91e82f27f98030a8c34e8.pdf\" target=\"_blank\"\u003ePowerLogic™ Low Voltage Current Transducers - LVCT_Z205398-0H (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b6d79dedbb1081fffc4fdabab2bf436732a5e30b.DXF\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A.DXF\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7e7c2637e1a31bb207c243bce0a29f8985c13ad8.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_3D_0A (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b591658a315bc0d7d2e4a81c45a153ef9c857a7.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b3036e540a93bedf9386950b26afeedfa9f596ac.pdf\" target=\"_blank\"\u003eUK Declaration of Conformity - UKDOC_LVCT20xx__BCPMSCCTXX_LVCT00XX_A3-V2 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845650276656,"sku":"LVCT20202S","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/b504295c897376b527a5aeb40e9840fa6f39a256-large.png?v=1690380699"},{"product_id":"bcpmc142s-bcpm-power-monitoring-basic-42-solid-core-100-a-26-mm-ct-spacing","title":"BCPM power monitoring basic - 42 solid core 100 A - 26 mm CT spacing","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eVariant: basic\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPM\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMC\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eConnection Pitch: 26 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: current 2 % 0.25…2 A || current 1 % 2…100 A\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 42 solid core CT 100 A\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: high current alarm || low-low current alarm || low current alarm || high-high current alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 42 x current transformer || 2 x cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eMounting Mode: panel-mounted\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eStandards: ANSI C12.1 || UL 508 || EN 61010 || IEC 61036\u003c\/li\u003e\n\u003cli\u003eMounting Support: enclosure || panel\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/01b530e8c909a2e642765a1f31f8d883c103081c.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea8b9f5adb6069854bd3a295a4987961cb827524.pdf\" target=\"_blank\"\u003eBCPM_Solid Core Instruction Sheet - BCPM_Solid+Core+Quick_i0a2_+Z207197-0B_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845663449392,"sku":"BCPMC142S","price":4525.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/7704df5156365b38e19b0d53861883983adf7f71-large.png?v=1690380737"},{"product_id":"metseem4236-enercept-meter-class-0-2s-modbus-bacnet-rs-485-user-choice","title":"Enercept Meter, class 0.2S, Modbus\/BACnet RS-485, user choice, ANSI wire code","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic EM4200\u003c\/li\u003e\n\u003cli\u003eType Of Cable: ANSI cable\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Application: power monitoring\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: Enercept\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: bracket for support || hook\u003c\/li\u003e\n\u003cli\u003eHeight: 152.36 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-90 V AC 45...65 Hz minimum per phase || 480-480 V AC 45...65 Hz between phases || 300-300 V AC 45...65 Hz between phase and neutral\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 0\u003c\/li\u003e\n\u003cli\u003eStandards: EN 61010-1 || UL 61010-1 || CAN\/CSA C22.2 No. 61010-1-12\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE EN 61010-1 || cULus UL 61010-1 || BTL || ANSI\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU 9600 bauds...115200 bauds (automatic detection) || BACnet MS\/TP 9600 bauds...115200 bauds (automatic detection)\u003c\/li\u003e\n\u003cli\u003eFrequency Measurement Range: 45-65 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: remote control orders || total energy || net energy\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 0\u003c\/li\u003e\n\u003cli\u003eNet Weight: 4 kg\u003c\/li\u003e\n\u003cli\u003eDepth: 35.81 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 50-5000 A\u003c\/li\u003e\n\u003cli\u003eWire Stripping Length: 6 mm\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: status LED green and red) || line fault 3 LED green, orange and red) || dial pointer indication LED Yellow) || RX\/TX 2 LED green, orange and red)\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: input\/output plug-in connector bottom) 0.2-1.5 mm² || current transformer plug-in connector bottom) 0.2-1.5 mm² || communication plug-in connector bottom) 0.2-1.5 mm²\u003c\/li\u003e\n\u003cli\u003eFunction Available: external synchronisation to communication || fixed or rolling block\u003c\/li\u003e\n\u003cli\u003eMounting Mode: by screws || clip-on || by hook\u003c\/li\u003e\n\u003cli\u003eControl Type: ADDRESS 1-99 rotary || CT AMPS 5-5000 rotary\u003c\/li\u003e\n\u003cli\u003eMounting Support: enclosure || DIN rail\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: current 0.333 V 33 kOhm) || voltage single phase 2.5 MOhm) || voltage phase to phase 5 MOhm)\u003c\/li\u003e\n\u003cli\u003eWidth: 46.63 mm\u003c\/li\u003e\n\u003cli\u003eDisplay Type: Without Display\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.2 ANSI C12.20 || class 1S IEC 62053-24\u003c\/li\u003e\n\u003cli\u003eMetering Type: active, reactive, apparent energy (signed, four quadrant) || apparent power S, S1, S2, S3 || demand power P, Q, S || active power P, P1, P2, P3 || reactive power Q, Q1, Q2, Q3 || power factor || average current Iavg || peak demand power PM, QM, SM || frequency || voltage U21, U32, U13, V1, V2, V3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -30-70 °C\u003c\/li\u003e\n\u003cli\u003eElectromagnetic Compatibility: conducted and radiated emissions FCC Part 15 class A || conducted and radiated emissions EN 61000-6-4 || conducted and radiated emissions EN 61326 + A1 || immunity to conducted disturbances EN 61000-6-2 || immunity to conducted disturbances EN 61326-1 || immunity to radiated fields EN 61000-6-2 || immunity to radiated fields EN 61326-1\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 %\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: IP20 IEC 60529\u003c\/li\u003e\n\u003cli\u003eMeasurement Category: category III 277-277 V || category III 300-300 V\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: \u0026lt; 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2103d91c8bcfe9cd07f3ed56e8ef86494d820a6b.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/198f737e2a98bb695d46f4052361acc0dd527ba8.pdf\" target=\"_blank\"\u003eEM4200_CAD - vbr_asm-3P-Univ_mst (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/074a30ae2892d13600f098f91285e40393947768.IGS\" target=\"_blank\"\u003eEM4200_CAD - vbr_asm-3P-Univ_mst.IGS\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4c662ee97985020e6f0424ddfe3b13900b257917.DXF\" target=\"_blank\"\u003eEM4200_CAD - vbr_asm-3P-Univ_mst.DXF\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9bc84a0eee480168a69ad5169ec6d66406ff431a.pdf\" target=\"_blank\"\u003eEM4200 Technical Datasheet - Web Version - PLSED310121EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c4adc3b0310aeb28bc799d58c9e95ac83ab07045.pdf\" target=\"_blank\"\u003eEM4200 Series compact power and energy meters instruction sheet - EM4200_FLEX_Z207168-0F (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845685010736,"sku":"METSEEM4236","price":800.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/6a051326fe04b2464306671bcd7eb64d5042a6fe-large.png?v=1690380840"},{"product_id":"bcpma248s-bcpm-power-monitoring-advanced-48-solid-core-100-a-18-mm-ct","title":"BCPM power monitoring advanced - 48 solid core 100 A - 18 mm CT spacing","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: voltage sag and swell detection\u003c\/li\u003e\n\u003cli\u003eVariant: advanced\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: voltage || current || frequency || active power || power factor || active energy\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPM\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eConnection Pitch: 18 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: low current alarm || over voltage alarm || high current alarm || under voltage alarm || high-high current alarm || low-low current alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 48 x current transformer\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 48 solid core CT 100 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 61036 || EN 61010 || UL 508 || ANSI C12.1\u003c\/li\u003e\n\u003cli\u003eMounting Support: enclosure || panel\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eMounting Mode: panel-mounted\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8b1c979ba3f0083bacf819bdd0060c921847c1ae.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea8b9f5adb6069854bd3a295a4987961cb827524.pdf\" target=\"_blank\"\u003eBCPM_Solid Core Instruction Sheet - BCPM_Solid+Core+Quick_i0a2_+Z207197-0B_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845729902896,"sku":"BCPMA248S","price":7536.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/7704df5156365b38e19b0d53861883983adf7f71-large_5bf074b0-d71a-4fc0-b4f7-e341f4907a5a.png?v=1690381047"},{"product_id":"lvct20403s-lvct-400a-0-333-v-output-solid-core-ct-31-mm","title":"LVCT 400A - 0.333 V output - solid core CT - Ã˜=31 mm","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eProduct Destination: BCPMCS || EM4200 || EM4900\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: cable 1.8 m600 V\u003c\/li\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic BCPMSC) BCPMSCA multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCB multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCE multi-circuit energy meter || PowerLogic (PowerLogic EM4200) EM4235 energy meter || PowerLogic (PowerLogic EM4200) EM4236 energy meter || PowerLogic (PowerLogic EM4900) EM4904 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4908 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4914 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4928 multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eAccessory \/ Separate Part Category: measurement accessory\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 0.333 V\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 400 A\u003c\/li\u003e\n\u003cli\u003eCurrent Transformer Type: A type closed toroid\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: current transformer\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: LVCT\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eMeasurement Accuracy: +\/- 0.5 % 5...120 %\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eToxic Heavy Metal Free: Yes\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -50-105 °C\u003c\/li\u003e\n\u003cli\u003eWidth: 70 mm\u003c\/li\u003e\n\u003cli\u003eHeight: diameter 31 mm || external 82 mm\u003c\/li\u003e\n\u003cli\u003eClimatic Withstand: relative humidity 95 %\u003c\/li\u003e\n\u003cli\u003eDepth: 25 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7d8acaf2750761d1262f6b171223fc1cbcb498e7.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c2a250d86b97e6b7b89284c0a2a0e8c0016f1303.pdf\" target=\"_blank\"\u003eEnergy Meter Kit Handout - Energy+Meter+Kit+2pg+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38569afb3de012bba3b91e82f27f98030a8c34e8.pdf\" target=\"_blank\"\u003ePowerLogic™ Low Voltage Current Transducers - LVCT_Z205398-0H (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b591658a315bc0d7d2e4a81c45a153ef9c857a7.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7e7c2637e1a31bb207c243bce0a29f8985c13ad8.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_3D_0A (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b6d79dedbb1081fffc4fdabab2bf436732a5e30b.DXF\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A.DXF\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b3036e540a93bedf9386950b26afeedfa9f596ac.pdf\" target=\"_blank\"\u003eUK Declaration of Conformity - UKDOC_LVCT20xx__BCPMSCCTXX_LVCT00XX_A3-V2 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845888237872,"sku":"LVCT20403S","price":140.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/b504295c897376b527a5aeb40e9840fa6f39a256-large_31712489-249e-4308-8d23-110ecfeba489.png?v=1690381718"},{"product_id":"bcpma142s-bcpm-power-monitoring-advanced-42-solid-core-100-a-26-mm-ct","title":"BCPM power monitoring advanced - 42 solid core 100 A - 26 mm CT spacing","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: voltage sag and swell detection\u003c\/li\u003e\n\u003cli\u003eVariant: advanced\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: voltage || current || frequency || active power || power factor || active energy\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPM\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eConnection Pitch: 26 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: high-high current alarm || over voltage alarm || high current alarm || under voltage alarm || low-low current alarm || low current alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 42 x current transformer || 2 x cables\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 42 solid core CT 100 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eStandards: ANSI C12.1 || IEC 61036 || UL 508 || EN 61010\u003c\/li\u003e\n\u003cli\u003eMounting Support: panel || enclosure\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eMounting Mode: panel-mounted\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a7828f71a441ab963a3b1c6b8bfc809f2396b374.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea8b9f5adb6069854bd3a295a4987961cb827524.pdf\" target=\"_blank\"\u003eBCPM_Solid Core Instruction Sheet - BCPM_Solid+Core+Quick_i0a2_+Z207197-0B_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845952725296,"sku":"BCPMA142S","price":6932.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/7704df5156365b38e19b0d53861883983adf7f71-large_4027182b-d0a4-4f35-b973-e51fb0087b9e.png?v=1690381975"},{"product_id":"bcpmscc42s-bcpm-power-monitoring-basic-42-split-core-ct-50-a","title":"BCPM power monitoring basic - 42 split core CT 50 A","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eVariant: basic\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPMSC\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMSCC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: low-low current alarm || high-high current alarm || low current alarm || high current alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 42 x current transformer || 2 x cables || 2 x adapter board\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: current 2 % 0.25…2 A || current 1 % 2…100 A\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 42 split core CT 0.333 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eStandards: UL 508 || EN 61010 || ANSI C12.1 || IEC 61036\u003c\/li\u003e\n\u003cli\u003eMounting Support: board\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/741ef4ac1459f8975a7d9ccc23a097594d6d6a8d.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/35af3743e80be6a0b469d24740263fd3fb3b17b0.pdf\" target=\"_blank\"\u003eBCPM_Split Core Instruction Sheet - BCPM_Split+Core+Quick_i0a2_+Z207196-0A_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845955117360,"sku":"BCPMSCC42S","price":5606.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/7704df5156365b38e19b0d53861883983adf7f71-large_9b82e549-3e94-45ca-b639-584058c8c758.png?v=1690381984"},{"product_id":"a9mem3300-iem3300-energy-meter-125-a","title":"iEM3300 energy meter - 125 A","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: Acti9 iEM3000\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: iEM3300\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 32 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 61557-12 || IEC 61557-12 || EN 61557-12 || BS EN 61326-1 || IEC 61326-1 || EN 61326-1 || BS EN 62052-11 || IEC 62052-11 || EN 62052-11 || BS EN 62053-21 || IEC 62053-21 || EN 62053-21 || BS EN 62052-31 || IEC 62052-31 || EN 62052-31 || BS EN 61010-1 || EN 61010-1 || IEC 61010-1 || UL 61010-1 || BS EN 61010-2-30 || IEC 61010-2-30 || EN 61010-2-30 || UL 61010-2-30 || ANSI C12.16\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 0\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003eMaximum Value Measured: 99999999.9 kWh\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: active energy\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 safety) || CE EN 61557-12 power monitor) || CE EN\/IEC 61326-1 EMC) || UKCA BS EN 61010-1 safety) || UKCA BS EN 61557-12 power monitor) || UKCA BS EN 61326-1 EMC) || cULus UL 61010-1 safety) || cULus EN 61010-1 safety) || EAC sub-meter) || RCM NMI M 6-1 || KZ || NMI NMI M 6-1\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 0\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 0-125 A\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: screw terminals 50-50 mm²\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: Green indicator light power ON || Yellow flashing LED accuracy checking\u003c\/li\u003e\n\u003cli\u003eTechnology Type: electronic\u003c\/li\u003e\n\u003cli\u003ePoles Description: 1P + N || 3P + N || 3P\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 125 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: direct input\u003c\/li\u003e\n\u003cli\u003eDisplay Type: LCD display\u003c\/li\u003e\n\u003cli\u003eOvervoltage Category: III\u003c\/li\u003e\n\u003cli\u003eDevice Application: partial meter || sub billing\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 1 active energy IEC 62053-21 || class 1 active energy IEC 61557-12 || class B active energy EN 50470-3\u003c\/li\u003e\n\u003cli\u003eRated Voltage: 100-277 V || 173-480 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP1404007EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI1404007EN\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 103.2 mm\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-60 °C - IEC\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003e9 Mm Pitches: 14\u003c\/li\u003e\n\u003cli\u003eColor: White\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: front panel IP40 IEC 60529 || body IP20 IEC 60529\u003c\/li\u003e\n\u003cli\u003eWidth: 126 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 69.3 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: \u0026lt; 6561.68 ft (2000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/86e00b08a889bd15591f6af6a4b4fbf4487f7d55.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/39db586ef7e0eb473f42aff422294b3f2e8cea23.dxf\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/10623c0e7b74a303aa85823532d0eedf6cda5fa0.dwg\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/794ed3692f19e91b35677889c97ef41504fee1f4.dxf\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c5bd52e25912edab55bedc9ad87c1473c3e26fd0.stp\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Simplified File - A9MEM3300_3D-Simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c636d9b83d522bcc38210c95d37c2c1c7e7b538e.dwg\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/88a012740828cbf1a2c2cd7f8a3345f03f5d018b.dwg\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2df9d05a59325a48b2dc0a840bf4b6a6907d34f2.dxf\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/bda25dbd00c985a234d7181e09a2f2c3e7f3a9cb.dxf\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ba0bd708a30577aaeb948fcf13232ef3034221fb.dwg\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3f2c814f49bc6a8f35edc6dde8db6f9613aa4626.dxf\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/256d447da9d4aff79adc2192ac5d40331e07d819.dxf\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ba76620aeb97a660f65b474f3ac7ccb2e0079842.dwg\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d0523c68ab7641acafd7a6101a5dc43e307e1cf5.dwg\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ba9e8253921075c378f83048fd314ce80dac9e8.dwg\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3818e79ca810c3880153593fa1d7c0c8e3194159.dxf\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ab2c09cac1d7e93ed7b5402b2678e1fe37f50cc0.stp\" target=\"_blank\"\u003eiEM3300_Energy Meter_3D CAD_Zip File - MCADDE0000097_3D-simplified (stp)\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/47d0f013f9b260edda2389a977d559cf608ac75f.pdf\" target=\"_blank\"\u003eiEM33xx series_EAC Certificate - iEM+3300-EAC (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d660a3dfc9857f579ac688ccca7f5687749c9934.pdf\" target=\"_blank\"\u003eiEM33xx series_ EAC Metrology Certificate - iEM3300_metrology_19 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/368bf7aa4cb7974df1abb17a5800501ffbd814d3.zip\" target=\"_blank\"\u003eiEM3000 series_METAS Certificate-Reactive Energy - CH-CH003-21022-01_IN-SE_iEM3zxy_+Metas+certificate (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/471935bf4c96ee1bf5ed78f9af0d07e76ad61255.pdf\" target=\"_blank\"\u003eiEM3000 series_UL_Certificate of Compliance - CoC+-iEM33xx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6a998ceee52d7b0b2e15790417dd65e11dc0931e.pdf\" target=\"_blank\"\u003eiEM3000 series_NMI_M 6-1 Certificate - 14-2-89_r4 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/00b65510d3f09bc4b6a325b49c7acc2c10ee3942.pdf\" target=\"_blank\"\u003eiEM3000 series_UL_CB Certificate - DK-55005-A1-UL (pdf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/74f5e0d9fa41a76b5d4db8768ac354af4ec1df95.pdf\" target=\"_blank\"\u003eMulti-Meter Unit Enclosures for iEM3000 Energy Meters Brochure - Multiple+Meter+Unit+Enclosure+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/01152f7ab0198d89946ee7e1b9886a7650a44a31.pdf\" target=\"_blank\"\u003eChanges to the 2020 National Electrical Code Brochure - 998-21037672_GMA-US_NEC+2020+eGuide (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c9764ff65d8d05dcf4464010c90971f0a2a0f6ac.pdf\" target=\"_blank\"\u003eiEM3000 Triphase kWh meter - EoLi - ENVEOLI1404007EN (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/24fcfd80172bd5030757e948ff10136f98bd822c.pdf\" target=\"_blank\"\u003eUK Declaration of Conformity - UKDOC__iEM3000_A7-V3.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8e07d2f206b824ba87fee2a8bd3b16460abcaecd.pdf\" target=\"_blank\"\u003eiEM3000 series_EU Declaration of Conformity - ECDiEM3000-V8a.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a39fdbcc40bf1fd09b613423f3b750ee8a5d1a0d.pdf\" target=\"_blank\"\u003eiEM3000 series_RCM_Certificate - SDOC+iEM3000 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c659275f5417d564bbbe71e142d6cc4a534a36bd.pdf\" target=\"_blank\"\u003eiEM3300 \/ iEM3350 - Instruction sheet - HRB91204-04 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c8e23486b0d423af2635cb6cce3a09e9aca82339.pdf\" target=\"_blank\"\u003eiEM3100 \/ iEM3200 \/ iEM3300 series- User Manual - DOCA0005EN-13 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/799acf5ff6ce4008b2aba9993b2fa9186b318052.zip\" target=\"_blank\"\u003eActi 9 iEM3355 energy meter, Environmental Disclosure, Product Environmental Profile - ENVPEP1404007EN (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845955510576,"sku":"A9MEM3300","price":621.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/cd80a717e0f353fc680b09366bb71e98a7fa5e9a-large.png?v=1690381986"},{"product_id":"lvct00050s-lvct-50-a-0-333-v-output-split-core-ct-10-mm-x-h-11-mm","title":"LVCT 50 A - 0.333 V output - split core CT - Ã˜=10 mm x H=11 mm","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eProduct Destination: BCPM || BCPMSC || Enercept || iEM3000 || EM3500 || EM4200 || EM4900\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: cable 1.8 m AWG 22) 600 V\u003c\/li\u003e\n\u003cli\u003eAccessory \/ Separate Part Category: measurement accessory\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: current transformer\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 0.333 V\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 50 A\u003c\/li\u003e\n\u003cli\u003eCurrent Transformer Type: split core balance\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: LVCT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic BCPM) BCPMA multi-circuit energy meter || PowerLogic (PowerLogic BCPM) BCPMB multi-circuit energy meter || PowerLogic (PowerLogic BCPM) BCPME multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCA multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCB multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCE multi-circuit energy meter || PowerLogic (PowerLogic EM3500) EM3502 energy meter || PowerLogic (PowerLogic EM3500) EM3550 energy meter || PowerLogic (PowerLogic EM3500) EM3555 energy meter || PowerLogic (PowerLogic EM3500) EM3560 energy meter || PowerLogic (PowerLogic EM3500) EM3561 energy meter || PowerLogic (PowerLogic EM4200) EM4235 energy meter || PowerLogic (PowerLogic EM4200) EM4236 energy meter || PowerLogic (PowerLogic EM4900) EM4904 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4908 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4914 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4928 multi-circuit energy meter || Acti 9 (Acti9 iEM3000) iEM3455 energy meter || Acti 9 (Acti9 iEM3000) iEM3465 energy meter\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: 1 % 10...100 %\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eToxic Heavy Metal Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: 0-70 °C\u003c\/li\u003e\n\u003cli\u003eDepth: 26 mm\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-105 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 95-95 %\u003c\/li\u003e\n\u003cli\u003eWidth: internal 10 mm || external 23 mm\u003c\/li\u003e\n\u003cli\u003eHeight: internal 11 mm || external 40 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/71975da46e599ca1ff782f76e1af57cde47686e7.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c2a250d86b97e6b7b89284c0a2a0e8c0016f1303.pdf\" target=\"_blank\"\u003eEnergy Meter Kit Handout - Energy+Meter+Kit+2pg+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38569afb3de012bba3b91e82f27f98030a8c34e8.pdf\" target=\"_blank\"\u003ePowerLogic™ Low Voltage Current Transducers - LVCT_Z205398-0H (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b591658a315bc0d7d2e4a81c45a153ef9c857a7.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b6d79dedbb1081fffc4fdabab2bf436732a5e30b.DXF\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A.DXF\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7e7c2637e1a31bb207c243bce0a29f8985c13ad8.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_3D_0A (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b3036e540a93bedf9386950b26afeedfa9f596ac.pdf\" target=\"_blank\"\u003eUK Declaration of Conformity - UKDOC_LVCT20xx__BCPMSCCTXX_LVCT00XX_A3-V2 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845966455088,"sku":"LVCT00050S","price":87.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/4077628acedaed9824976a06a8cd3e51b453ea27-large.png?v=1690382033"},{"product_id":"bcpmscc1s-2-adapter-boards-basic-current-on-all-circuits","title":"2 adapter boards - basic - current on all circuits","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eVariant: basic\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPMSC\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMSCC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: high-high current alarm || high current alarm || low current alarm || low-low current alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 2 x adapter board || 0 x current transformer\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: current 2 % 0.25…2 A || current 1 % 2…100 A\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 42 current 0.333 V || current 1 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: 0-60 °C\u003c\/li\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 61010-1 || EN 61010\u003c\/li\u003e\n\u003cli\u003eMounting Support: board\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL 508\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 95-95 %\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/39a6bbf820d369fa48f92c6f790e890dd96f147c.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/35af3743e80be6a0b469d24740263fd3fb3b17b0.pdf\" target=\"_blank\"\u003eBCPM_Split Core Instruction Sheet - BCPM_Split+Core+Quick_i0a2_+Z207196-0A_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845971337520,"sku":"BCPMSCC1S","price":3208.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/bf9a8d8b7d2e9213e6c96deaf753b3ed651566b5-large.png?v=1690382054"},{"product_id":"bcpma084s-bcpm-power-monitoring-advanced-84-solid-core-100-a-19-mm-ct","title":"BCPM power monitoring advanced - 84 solid core 100 A - 19 mm CT spacing","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: voltage sag and swell detection\u003c\/li\u003e\n\u003cli\u003eVariant: advanced\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: voltage || current || frequency || active power || power factor || active energy\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPM\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eConnection Pitch: 19 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: low-low current alarm || low current alarm || under voltage alarm || high current alarm || over voltage alarm || high-high current alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 84 x current transformer || 4 x cables\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 84 solid core CT 100 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eStandards: ANSI C12.1 || EN 61010 || IEC 61036 || UL 508\u003c\/li\u003e\n\u003cli\u003eMounting Support: panel || enclosure\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eMounting Mode: panel-mounted\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4d6b0d11b9e08d0e543c1c1b78a9169dfedcd0dd.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea8b9f5adb6069854bd3a295a4987961cb827524.pdf\" target=\"_blank\"\u003eBCPM_Solid Core Instruction Sheet - BCPM_Solid+Core+Quick_i0a2_+Z207197-0B_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845989392688,"sku":"BCPMA084S","price":11161.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/7704df5156365b38e19b0d53861883983adf7f71-large_a5502da2-ea75-4624-88cb-61130c38638d.png?v=1690382112"},{"product_id":"cbl019-cable-ribbon-97-in-bcm","title":"Cable, Ribbon, 97 in, BCM","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: PowerLogic\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: ribbon cable\u003c\/li\u003e\n\u003cli\u003eLength: 2.4 m\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: CBL\u003c\/li\u003e\n\u003cli\u003eType Of Cable: flat\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Destination: BCPM\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1f6e232ffd434cf21b888992bce13caef7199bb2.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845991293232,"sku":"CBL019","price":70.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/9108b61839cab7cf499f210b2d935f45efbd98e5-large_011ebe63-8b0c-47e5-9f13-ee364ab97b76.png?v=1690382136"},{"product_id":"a9mem3175-iem3175-energy-meter-63-a-lon-1-digital-i-multi-tariff-mid","title":"iEM3175 energy meter - 63 A - LON - 1 digital I - multi-tariff - MID","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: Acti9 iEM3000\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: iEM3175\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: screw terminal block LonWorks TP\/FT-10\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 32 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 61557-12 || IEC 61557-12 || EN 61557-12 || BS EN 61326-1 || IEC 61326-1 || EN 61326-1 || BS EN 62052-11 || IEC 62052-11 || EN 62052-11 || BS EN 62053-21 || IEC 62053-21 || EN 62053-21 || BS EN 62052-23 || IEC 62053-23 || EN 62052-23 || BS EN 62052-31 || IEC 62052-31 || EN 62052-31 || BS EN 61010-1 || EN 61010-1 || IEC 61010-1 || UL 61010-1 || BS EN 61010-2-30 || IEC 61010-2-30 || EN 61010-2-30 || UL 61010-2-30 || BS EN 50470-3 || EN 50470-3 || BS EN 50470-1 || EN 50470-1 || ANSI C12.16\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 0\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003eMaximum Value Measured: 99999999.9 kWh\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: active and reactive energy || active and reactive power || current || voltage\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: LON 3750 V\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 safety) || CE EN 61557-12 power monitor) || CE EN\/IEC 61326-1 EMC) || UKCA BS EN 61010-1 safety) || UKCA BS EN 61557-12 power monitor) || UKCA BS EN 61326-1 EMC) || cULus UL 61010-1 safety) || cULus EN 61010-1 safety) || EAC EN 50470-3 sub-meter) || RCM EN 62052 sub-meter) || KZ EN 50470-3 sub-meter) || METAS EN 50470-1 sub-meter) || MID EN 50470-3 sub-meter) || MID EN 50470-1 sub-meter) || NMI NMI M 6-1\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 1 digital 0...5 V\/11...40 V 24 V DC\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 0-63 A\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: screw terminals 16-16 mm²\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: tariff 4)\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: Green indicator light power ON || Yellow flashing LED accuracy checking || alarm overload\u003c\/li\u003e\n\u003cli\u003eTechnology Type: electronic\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P || 3P + N || 1P + N\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 63 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: direct input\u003c\/li\u003e\n\u003cli\u003eDisplay Type: LCD display\u003c\/li\u003e\n\u003cli\u003eOvervoltage Category: III\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing || partial meter || multi-tariff\u003c\/li\u003e\n\u003cli\u003eMetering Type: active, reactive, apparent energy (signed, four quadrant)\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 1 active energy IEC 62053-21 || class 1 active energy IEC 61557-12 || class B active energy EN 50470-3\u003c\/li\u003e\n\u003cli\u003eRated Voltage: 100-277 V || 173-480 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP111276EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI111261EN_V1\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 95 mm\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-55 °C - MID || -25-60 °C - NMI || -25-60 °C - IEC\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003e9 Mm Pitches: 10\u003c\/li\u003e\n\u003cli\u003eColor: White\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: front panel IP40 IEC 60529 || body IP20 IEC 60529\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 69 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: \u0026lt; 6561.68 ft (2000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/cf6d4515923671e65af1fffdc7db7542a3f2c93b.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/37e9e1ac818f44f1a7d175c08864cb2ca38be712.zip\" target=\"_blank\"\u003eiEM3000 series_UL_CB Certificate - DK-117783-UL (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ec6e512e9cf7405638b1974181735d504a765d2e.pdf\" target=\"_blank\"\u003eiEM31xx_iEM32xx_ PM32xx_series_ EAC Certificate - iEM3000+EAC (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6a998ceee52d7b0b2e15790417dd65e11dc0931e.pdf\" target=\"_blank\"\u003eiEM3000 series_NMI_M 6-1 Certificate - 14-2-89_r4 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e1aac6c4af4ea886054fbcf25bd509b2bd404f0e.zip\" target=\"_blank\"\u003eiEM3000 series_UL_Certificate of Compliance - UL_Certificate+of+compliance (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8ea0690847ea9e840ccd6a08ad8dfc5f33dcf3.pdf\" target=\"_blank\"\u003eiEM3000 series_MID_Module B Certificate - SGS0098_+iEM31xx+_33xx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5945a611ee77f2bb3dccd2637eab2b017bef6772.pdf\" target=\"_blank\"\u003eiEM3000 series MID_Module D Certificate - iEM3000+series+MID_Module+D+Certificate (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/368bf7aa4cb7974df1abb17a5800501ffbd814d3.zip\" target=\"_blank\"\u003eiEM3000 series_METAS_Certificate_Reactive Energy_MID variants - CH-CH003-21022-01_IN-SE_iEM3zxy_+Metas+certificate (pdf)\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3551742cab989d7aead571fe391bc9e640f1fd33.dwg\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1443522c743a9628c79f50282eb0127542c9cbc7.dwg\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4402c4b63453fb1d7273d3d882f0090cc34f16fe.dwg\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/eb0e48970fff4f68376cf21260c0324b5cf78d0a.dxf\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9dd71a5ce0fbb8bd62a8079f3bf70719e7f83989.stp\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Simplified File - A9MEM3175_3D-Simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e41475ac74aa63767e9b650bb84bc7551b95e2da.dwg\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/564c8392d584e4c79b1acf1ea42e255e469e40a4.dxf\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/57f5081524b4504260c45c11cdf16883f9867e16.dwg\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fdb95a8757e986ab4602a3f7232e00a66f13c6b7.dwg\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/14f3071dafe8c4b1362c290a6a4dec4120fed515.stp\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_3D-simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8da98dbf217a098737b83471d107fdb7134e6549.dxf\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/eba49d6ef844d04659a727c790651c6fe575dce6.dxf\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59ee07e163758c97f5e6063589be6cc6917dd6b3.dwg\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/64a3777493ca09c7529a1975954bc3bb325de85a.dxf\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e9a6fc9c800912a02dd45384ad3ccbe671c7c85d.dxf\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b0eccb27237136534af82b1e2d0de8acaac13778.dxf\" target=\"_blank\"\u003eiEM3175_Energy Meter_3D CAD_Zip File - MCADDE0000090_2D-bottom (dxf)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/01152f7ab0198d89946ee7e1b9886a7650a44a31.pdf\" target=\"_blank\"\u003eChanges to the 2020 National Electrical Code Brochure - 998-21037672_GMA-US_NEC+2020+eGuide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/74f5e0d9fa41a76b5d4db8768ac354af4ec1df95.pdf\" target=\"_blank\"\u003eMulti-Meter Unit Enclosures for iEM3000 Energy Meters Brochure - Multiple+Meter+Unit+Enclosure+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b1ee4adf33db7b218edba3d55eeb61b7a3ff8b9b.pdf\" target=\"_blank\"\u003eiEM3000 Range _EU Declaration of Conformity _MID versions - ECDiEM3000-MID-V9a.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b2c84399eb01531795ab9c59c0fa960f6f28374e.pdf\" target=\"_blank\"\u003eUKCA MIR_ Declaration of Conformity - UKMIRDOCiEM3000-A7-V3.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a39fdbcc40bf1fd09b613423f3b750ee8a5d1a0d.pdf\" target=\"_blank\"\u003eiEM3000 series_RCM_Certificate - SDOC+iEM3000 (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea9971dd6fb1f5c5c20c4b65070cfe842c47901c.pdf\" target=\"_blank\"\u003eiEM3100 \/ iEM3200 \/ iEM3300 series_MID Sealing Instructions - Instruction sheet - NNZ7213200-00 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c8e23486b0d423af2635cb6cce3a09e9aca82339.pdf\" target=\"_blank\"\u003eiEM3100 \/ iEM3200 \/ iEM3300 series- User Manual - DOCA0005EN-13 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7eb3dae2d1ccae3d32a25bc9def2aa17e7b890ea.pdf\" target=\"_blank\"\u003eActi 9 iEM3000 energy meter, Circularity Profile, End of Life Instructions - ENVEOLI111261EN_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/987d8a66cde76fce5acb6d14b66ed58f94c00951.pdf\" target=\"_blank\"\u003eActi 9 iEM3000 energy meter, Environmental Disclosure, Product Environmental Profile - ENVPEP111276EN_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f013fc7da71e1cdad5b2047fd71c5fa535fcb074.pdf\" target=\"_blank\"\u003eiEM3110 \/ iEM3115 \/ iEM3135 \/ iEM3155 \/ iEM3165 \/ iEM3175 - Instruction sheet - NHA15789-05 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45845998567728,"sku":"A9MEM3175","price":942.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/963843c37912e478203d2e61c51b5c553df78ec4-large.png?v=1690382161"},{"product_id":"bcpmscc2s-4-adapter-boards-basic-current-on-all-circuits","title":"4 adapter boards - basic - current on all circuits","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eVariant: basic\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPMSC\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMSCC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: high-high current alarm || low-low current alarm || high current alarm || low current alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 4 x adapter board || 0 x current transformer\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: current 2 % 0.25…2 A || current 1 % 2…100 A\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: current 1 V || 84 current 0.333 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: 0-60 °C\u003c\/li\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eStandards: EN 61010 || IEC 61010-1\u003c\/li\u003e\n\u003cli\u003eMounting Support: board\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL 508\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 95-95 %\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f0e1a1f57b510a539ccbc51dd33de8a1fb0b6cb8.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/35af3743e80be6a0b469d24740263fd3fb3b17b0.pdf\" target=\"_blank\"\u003eBCPM_Split Core Instruction Sheet - BCPM_Split+Core+Quick_i0a2_+Z207196-0A_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846013673776,"sku":"BCPMSCC2S","price":5171.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/bf9a8d8b7d2e9213e6c96deaf753b3ed651566b5-large_a2affda8-15ac-4f6b-95e5-b89de7abefcd.png?v=1690382231"},{"product_id":"metseem3502-powerlogic-em3500-din-rail-meter-pulse-current-transformer","title":"PowerLogic EM3500 DIN rail meter - pulse - current transformer","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic EM3500\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: EM3502\u003c\/li\u003e\n\u003cli\u003eMetering Type: demand power P, Q, S || peak demand power PM, QM, SM || current I1, I2, I3, Iavg || voltage U21, U32, U13, V1, V2, V3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 90...347 V AC 50\/60 Hz between phase and neutral UL || 156...600 V AC 50\/60 Hz between phases UL || 90...300 V AC 50\/60 Hz between phase and neutral CE || 125...300 V DC\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 30 V AC\/DC\u003c\/li\u003e\n\u003cli\u003eStandards: UL 508 || CSA C22.2 No 14-05 || IEC 61010-1\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 2 pulse || 1 alarm output\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003ePower Consumption In Va: 5-5 VA 347 V AC between phase and neutral) || 5-5 VA 600 V AC between phases)\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010 || cULus UL 508\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: active and reactive power total || active and reactive power per phase || apparent power total || apparent power per phase || power factor total || power factor per phase || peak demand power || current || voltage || frequency\u003c\/li\u003e\n\u003cli\u003eCommunication Service: total cumulated active energy || total cumulated energy\u003c\/li\u003e\n\u003cli\u003eRide-Through Time: 100 ms 120 V AC\u003c\/li\u003e\n\u003cli\u003eDisplay Digits: 5\u003c\/li\u003e\n\u003cli\u003eTamperproof Of Settings: protected by access code\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 5-32000 A\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: status and alert || communication with system || input\/output status || error || Tx activity || Rx activity || instant power per usage\u003c\/li\u003e\n\u003cli\u003eFunction Available: fixed or rolling block\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on || by screws\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: Red LED threshold reached || Green flashing LED output signal\u003c\/li\u003e\n\u003cli\u003ePower Consumption In W: 3 W 300-300 V\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: power +\/- 0.2 % || energy +\/- 0.2 %\u003c\/li\u003e\n\u003cli\u003eTechnology Type: electronic\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P + N\u003c\/li\u003e\n\u003cli\u003eData Recording: energy consumption logs\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: split core current transducer 0.333 V or 1 V\u003c\/li\u003e\n\u003cli\u003eDisplay Type: Backlit LCD\u003c\/li\u003e\n\u003cli\u003eDevice Application: partial meter || sub billing\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.2S power IEC 62053-22 || class 0.2S energy IEC 62053-22 || class 0.2S power ANSI C12.20 || class 0.2S energy ANSI C12.20\u003c\/li\u003e\n\u003cli\u003eRated Voltage: 90-347 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -30-70 °C\u003c\/li\u003e\n\u003cli\u003eHeight: 91 mm\u003c\/li\u003e\n\u003cli\u003e9 Mm Pitches: 12\u003c\/li\u003e\n\u003cli\u003eColor: dark grey\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 %\u003c\/li\u003e\n\u003cli\u003eWidth: 107 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 59 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/789f29278ff1e345d91f077a91729ab938445177.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/bf0be01f351baa6f67348ae0f6d4d7ac6580c75e.pdf\" target=\"_blank\"\u003ePowerLogic EM3500 series Technical Datasheet - PLSED310037EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efa143c0c5263fb1977125b93a4b249b6a4b311.pdf\" target=\"_blank\"\u003eEM35xx Series Compact Power and Energy Meter Instruction Sheet - EM35xx_quick_Z206079-0F (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846017343792,"sku":"METSEEM3502","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/23e83226e803e1b127ffbd24b675f8ad8cc22553-large.png?v=1690382245"},{"product_id":"bcpmc084s-bcpm-power-monitoring-basic-84-solid-core-100-a-19-mm-ct-spacing","title":"BCPM power monitoring basic - 84 solid core 100 A - 19 mm CT spacing","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eVariant: basic\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: current\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPM\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eConnection Pitch: 19 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: high-high current alarm || low-low current alarm || high current alarm || low current alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 84 x current transformer || 4 x cables\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: current 2 % 0.25…2 A || current 1 % 2…100 A\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 84 solid core CT 100 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eStandards: UL 508 || IEC 61036 || EN 61010 || ANSI C12.1\u003c\/li\u003e\n\u003cli\u003eMounting Support: panel || enclosure\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eMounting Mode: panel-mounted\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d61780b76ab6784ba55385c0ac024d5c57632ec6.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea8b9f5adb6069854bd3a295a4987961cb827524.pdf\" target=\"_blank\"\u003eBCPM_Solid Core Instruction Sheet - BCPM_Solid+Core+Quick_i0a2_+Z207197-0B_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846027731248,"sku":"BCPMC084S","price":6788.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/7704df5156365b38e19b0d53861883983adf7f71-large_cea009a1-9e06-4e63-b16a-8bc4cf3aa26b.png?v=1690382288"},{"product_id":"a9mem3110-iem3110-energy-meter-63-a-1-pulse-o-mid","title":"iEM3110 energy meter - 63 A - 1 pulse O - MID","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: Acti9 iEM3000\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: iEM3110\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 32 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 61557-12 || IEC 61557-12 || EN 61557-12 || BS EN 61326-1 || IEC 61326-1 || EN 61326-1 || BS EN 62052-11 || IEC 62052-11 || EN 62052-11 || BS EN 62053-21 || IEC 62053-21 || EN 62053-21 || BS EN 62052-23 || IEC 62053-23 || EN 62052-23 || BS EN 62052-31 || IEC 62052-31 || EN 62052-31 || BS EN 61010-1 || EN 61010-1 || IEC 61010-1 || UL 61010-1 || BS EN 61010-2-30 || IEC 61010-2-30 || EN 61010-2-30 || UL 61010-2-30 || BS EN 50470-3 || EN 50470-3 || BS EN 50470-1 || EN 50470-1 || ANSI C12.16\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 1 pulse\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003eMaximum Value Measured: 99999999.9 kWh\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: active energy\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 safety) || CE EN 61557-12 power monitor) || CE EN\/IEC 61326-1 EMC) || UKCA BS EN 61010-1 safety) || UKCA BS EN 61557-12 power monitor) || UKCA BS EN 61326-1 EMC) || cULus UL 61010-1 safety) || cULus EN 61010-1 safety) || EAC EN 50470-3 sub-meter) || RCM EN 62052 sub-meter) || KZ EN 50470-3 sub-meter) || METAS EN 50470-1 sub-meter) || MID EN 50470-3 sub-meter) || MID EN 50470-1 sub-meter) || NMI NMI M 6-1\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 0\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 0-63 A\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: screw terminals 16-16 mm²\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: Green indicator light power ON || Yellow flashing LED accuracy checking\u003c\/li\u003e\n\u003cli\u003eTechnology Type: electronic\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P || 1P + N || 3P + N\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 63 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: direct input\u003c\/li\u003e\n\u003cli\u003eDisplay Type: LCD display\u003c\/li\u003e\n\u003cli\u003eOvervoltage Category: III\u003c\/li\u003e\n\u003cli\u003eDevice Application: partial meter || sub billing\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 1 active energy IEC 62053-21 || class 1 active energy IEC 61557-12 || class B active energy EN 50470-3\u003c\/li\u003e\n\u003cli\u003eRated Voltage: 100-277 V || 173-480 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP111276EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI111261EN_V1\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 95 mm\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-55 °C - MID || -25-60 °C - NMI || -25-60 °C - IEC\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003e9 Mm Pitches: 10\u003c\/li\u003e\n\u003cli\u003eColor: White\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: front panel IP40 IEC 60529 || body IP20 IEC 60529\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 69 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: \u0026lt; 6561.68 ft (2000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2746dd5c8cc174fe038d867d013e3810f4dfd192.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/37e9e1ac818f44f1a7d175c08864cb2ca38be712.zip\" target=\"_blank\"\u003eiEM3000 series_UL_CB Certificate - DK-117783-UL (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6a998ceee52d7b0b2e15790417dd65e11dc0931e.pdf\" target=\"_blank\"\u003eiEM3000 series_NMI_M 6-1 Certificate - 14-2-89_r4 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5945a611ee77f2bb3dccd2637eab2b017bef6772.pdf\" target=\"_blank\"\u003eiEM3000 series MID_Module D Certificate - iEM3000+series+MID_Module+D+Certificate (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8ea0690847ea9e840ccd6a08ad8dfc5f33dcf3.pdf\" target=\"_blank\"\u003eiEM3000 series_MID_Module B Certificate - SGS0098_+iEM31xx+_33xx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e1aac6c4af4ea886054fbcf25bd509b2bd404f0e.zip\" target=\"_blank\"\u003eiEM3000 series_UL_Certificate of Compliance - UL_Certificate+of+compliance (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/368bf7aa4cb7974df1abb17a5800501ffbd814d3.zip\" target=\"_blank\"\u003eiEM3000 series_METAS_Certificate_Reactive Energy_MID variants - CH-CH003-21022-01_IN-SE_iEM3zxy_+Metas+certificate (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ec6e512e9cf7405638b1974181735d504a765d2e.pdf\" target=\"_blank\"\u003eiEM31xx_iEM32xx_ PM32xx_series_ EAC Certificate - iEM3000+EAC (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0c5dde63abeaafb852864e3c55aa70f0021692ed.pdf\" target=\"_blank\"\u003eiEM31xx_iEM32xx series_ EAC Metrology Certificate - iEM3000_metrology (pdf)\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a2cdecc8e7fe4106d0a922f502c31774e8118c73.dwg\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/bd7962271a4d888a97adc228710d3ef658a6f44d.dwg\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/66f9242c093811e63b84a196812bbeac36367698.dxf\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8090cdb36f1d999ea3168b5251ff03c82701ae89.dxf\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7706f5839e7cf07b69ecc10d574992b255a9238f.dwg\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9d4d98f4b285fd76a5b26009a81c69f19f36eb1b.dxf\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a507ba31edc0d185c591ab5043388e257ab6f5cb.dxf\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/14171c9b4c8481890e5b5a8d70ac40046f22c6c9.dwg\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f6f85ee20870bcbdb4fb5dba1e4c7672949e532b.dwg\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/aa6f9d720368805541cfaa018d14eeb71a216072.dwg\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2a77ca4ad94a0f1417651d98722633be99db471d.dxf\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c922ccf8edadaa07c1cb021cbe9664dbcb64dd70.stp\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_3D-simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b4f07eabccdede5671458288da564ab2fb9bb2e.dxf\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5d49d073cc46a2ba5e80aff4c8dc945628bb202e.stp\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Simplified File - A9MEM3110_3D-Simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7799a311ffcc9023d0091c18ff0babb08bf9977c.dxf\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f6d927be71c75f4787b72526e00652e72d65c5e9.dwg\" target=\"_blank\"\u003eiEM3110_Energy Meter_3D CAD_Zip File - MCADDE0000084_2D-bottom (dwg)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/01152f7ab0198d89946ee7e1b9886a7650a44a31.pdf\" target=\"_blank\"\u003eChanges to the 2020 National Electrical Code Brochure - 998-21037672_GMA-US_NEC+2020+eGuide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/74f5e0d9fa41a76b5d4db8768ac354af4ec1df95.pdf\" target=\"_blank\"\u003eMulti-Meter Unit Enclosures for iEM3000 Energy Meters Brochure - Multiple+Meter+Unit+Enclosure+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b1ee4adf33db7b218edba3d55eeb61b7a3ff8b9b.pdf\" target=\"_blank\"\u003eiEM3000 Range _EU Declaration of Conformity _MID versions - ECDiEM3000-MID-V9a.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b2c84399eb01531795ab9c59c0fa960f6f28374e.pdf\" target=\"_blank\"\u003eUKCA MIR_ Declaration of Conformity - UKMIRDOCiEM3000-A7-V3.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a39fdbcc40bf1fd09b613423f3b750ee8a5d1a0d.pdf\" target=\"_blank\"\u003eiEM3000 series_RCM_Certificate - SDOC+iEM3000 (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea9971dd6fb1f5c5c20c4b65070cfe842c47901c.pdf\" target=\"_blank\"\u003eiEM3100 \/ iEM3200 \/ iEM3300 series_MID Sealing Instructions - Instruction sheet - NNZ7213200-00 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c8e23486b0d423af2635cb6cce3a09e9aca82339.pdf\" target=\"_blank\"\u003eiEM3100 \/ iEM3200 \/ iEM3300 series- User Manual - DOCA0005EN-13 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7eb3dae2d1ccae3d32a25bc9def2aa17e7b890ea.pdf\" target=\"_blank\"\u003eActi 9 iEM3000 energy meter, Circularity Profile, End of Life Instructions - ENVEOLI111261EN_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/987d8a66cde76fce5acb6d14b66ed58f94c00951.pdf\" target=\"_blank\"\u003eActi 9 iEM3000 energy meter, Environmental Disclosure, Product Environmental Profile - ENVPEP111276EN_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f013fc7da71e1cdad5b2047fd71c5fa535fcb074.pdf\" target=\"_blank\"\u003eiEM3110 \/ iEM3115 \/ iEM3135 \/ iEM3155 \/ iEM3165 \/ iEM3175 - Instruction sheet - NHA15789-05 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846031827248,"sku":"A9MEM3110","price":618.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/3dd91141baf49ef58bec2df8b4a268290ad26de3-large.png?v=1690382299"},{"product_id":"a9mem3100-iem3000-energy-meter-63-a","title":"iEM3000 energy meter - 63 A","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: Acti9 iEM3000\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: iEM3100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 32 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 61557-12 || IEC 61557-12 || EN 61557-12 || BS EN 61326-1 || IEC 61326-1 || EN 61326-1 || BS EN 62052-11 || IEC 62052-11 || EN 62052-11 || BS EN 62053-21 || IEC 62053-21 || EN 62053-21 || BS EN 62052-31 || IEC 62052-31 || EN 62052-31 || BS EN 61010-1 || EN 61010-1 || IEC 61010-1 || UL 61010-1 || BS EN 61010-2-30 || IEC 61010-2-30 || EN 61010-2-30 || UL 61010-2-30 || ANSI C12.16\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 0\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003eMaximum Value Measured: 99999999.9 kWh\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: active energy\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 safety) || CE EN 61557-12 power monitor) || CE EN\/IEC 61326-1 EMC) || UKCA BS EN 61010-1 safety) || UKCA BS EN 61557-12 power monitor) || UKCA BS EN 61326-1 EMC) || cULus UL 61010-1 safety) || cULus EN 61010-1 safety) || EAC sub-meter) || RCM NMI M 6-1 || KZ || NMI NMI M 6-1\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 0\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 0-63 A\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: screw terminals 16-16 mm²\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: Green indicator light power ON || Yellow flashing LED accuracy checking\u003c\/li\u003e\n\u003cli\u003eTechnology Type: electronic\u003c\/li\u003e\n\u003cli\u003ePoles Description: 1P + N || 3P || 3P + N\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 63 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: direct input\u003c\/li\u003e\n\u003cli\u003eDisplay Type: LCD display\u003c\/li\u003e\n\u003cli\u003eOvervoltage Category: III\u003c\/li\u003e\n\u003cli\u003eDevice Application: partial meter || sub billing\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 1 active energy IEC 62053-21 || class 1 active energy IEC 61557-12 || class B active energy EN 50470-3\u003c\/li\u003e\n\u003cli\u003eRated Voltage: 100-277 V || 173-480 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP111276EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI111261EN_V1\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 95 mm\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-60 °C - IEC\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003e9 Mm Pitches: 10\u003c\/li\u003e\n\u003cli\u003eColor: White\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: front panel IP40 IEC 60529 || body IP20 IEC 60529\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 69 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: \u0026lt; 6561.68 ft (2000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3eb840d4ff2913b725bfacc8d244053b040ea1c3.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e1aac6c4af4ea886054fbcf25bd509b2bd404f0e.zip\" target=\"_blank\"\u003eiEM3000 series_UL_Certificate of Compliance - UL_Certificate+of+compliance (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/368bf7aa4cb7974df1abb17a5800501ffbd814d3.zip\" target=\"_blank\"\u003eiEM3000 series_METAS Certificate-Reactive Energy - CH-CH003-21022-01_IN-SE_iEM3zxy_+Metas+certificate (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/6a998ceee52d7b0b2e15790417dd65e11dc0931e.pdf\" target=\"_blank\"\u003eiEM3000 series_NMI_M 6-1 Certificate - 14-2-89_r4 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/37e9e1ac818f44f1a7d175c08864cb2ca38be712.zip\" target=\"_blank\"\u003eiEM3000 series_UL_CB Certificate - DK-117783-UL (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0c5dde63abeaafb852864e3c55aa70f0021692ed.pdf\" target=\"_blank\"\u003eiEM31xx_iEM32xx series_ EAC Metrology Certificate - iEM3000_metrology (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ec6e512e9cf7405638b1974181735d504a765d2e.pdf\" target=\"_blank\"\u003eiEM31xx_iEM32xx_ PM32xx_series_ EAC Certificate - iEM3000+EAC (pdf)\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/db137d683b1fcadf6e28c8ff757d941d7de52cff.dxf\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e2830ba308c6528c4fb26e293748668df7a03546.dwg\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/73b9df7ab0ceb9301d53c2ae069b78ae2e757f81.dxf\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/09fe017e3370c63cefa0bd0fd6dacffe3921d98e.dwg\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fab02290f9f6189d5c065f0eced0a5672ccecb6b.dxf\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/475bc1a7ed98f32411c4d3b569e7705cf9ed3238.dxf\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0e58c9325092592b8e8511d3d7e868767769a6e8.dwg\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d72605f07cd31d29516ef54b2c360830990c7619.dwg\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a40f02d4fa5cec3e7986a91bfaa450e0de2936ba.stp\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D Simplified File - A9MEM3100_3D-Simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1b3fd50908f510af00a137b666cc3b541c7fabf7.dwg\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/34d1269941f8e02fe8cf7a46fddafbae32f0db8d.stp\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_3D-simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/053517bfac38d88fa82fcbeecdbc5e2d4cd948bd.dwg\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/65e8d8f859eaa333c6752e1252cd6a679dd7bb64.dxf\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/99995e533a9e787e38b67953a1e6ce84901f8a94.dxf\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fa272ae9829a5e11e91b96027e64f9299bc5f166.dxf\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/f87a27a2ef38576ad968a758f42760b2ae0c1745.dwg\" target=\"_blank\"\u003eiEM3100_Energy Meter_3D CAD_Zip File - MCADDE0000083_2D-right (dwg)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/74f5e0d9fa41a76b5d4db8768ac354af4ec1df95.pdf\" target=\"_blank\"\u003eMulti-Meter Unit Enclosures for iEM3000 Energy Meters Brochure - Multiple+Meter+Unit+Enclosure+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/01152f7ab0198d89946ee7e1b9886a7650a44a31.pdf\" target=\"_blank\"\u003eChanges to the 2020 National Electrical Code Brochure - 998-21037672_GMA-US_NEC+2020+eGuide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/24fcfd80172bd5030757e948ff10136f98bd822c.pdf\" target=\"_blank\"\u003eUK Declaration of Conformity - UKDOC__iEM3000_A7-V3.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a39fdbcc40bf1fd09b613423f3b750ee8a5d1a0d.pdf\" target=\"_blank\"\u003eiEM3000 series_RCM_Certificate - SDOC+iEM3000 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8e07d2f206b824ba87fee2a8bd3b16460abcaecd.pdf\" target=\"_blank\"\u003eiEM3000 series_EU Declaration of Conformity - ECDiEM3000-V8a.docx (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/21a44dc5b44481b6a15ed08d22d39b3e50998b8a.pdf\" target=\"_blank\"\u003eiEM3100 \/ iEM3150 - Instruction sheet - NHA15785-05 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c8e23486b0d423af2635cb6cce3a09e9aca82339.pdf\" target=\"_blank\"\u003eiEM3100 \/ iEM3200 \/ iEM3300 series- User Manual - DOCA0005EN-13 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7eb3dae2d1ccae3d32a25bc9def2aa17e7b890ea.pdf\" target=\"_blank\"\u003eActi 9 iEM3000 energy meter, Circularity Profile, End of Life Instructions - ENVEOLI111261EN_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/987d8a66cde76fce5acb6d14b66ed58f94c00951.pdf\" target=\"_blank\"\u003eActi 9 iEM3000 energy meter, Environmental Disclosure, Product Environmental Profile - ENVPEP111276EN_V1 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846058139952,"sku":"A9MEM3100","price":554.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/068fe0a3d3f1183673154822b248546e9df0753c-large.png?v=1690382416"},{"product_id":"bcpmb042s-bcpm-power-monitoring-intermediate-42-solid-core-100-a-19-mm-ct","title":"BCPM power monitoring intermediate - 42 solid core 100 A - 19 mm CT spacing","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: voltage sag and swell detection\u003c\/li\u003e\n\u003cli\u003eVariant: intermediate\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: voltage || current || frequency || active power || power factor || active energy\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPM\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eConnection Pitch: 19 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: low current alarm || under voltage alarm || high current alarm || low-low current alarm || high-high current alarm || over voltage alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 42 x current transformer || 2 x cables\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 42 solid core CT 100 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eStandards: EN 61010 || ANSI C12.1 || IEC 61036 || UL 508\u003c\/li\u003e\n\u003cli\u003eMounting Support: panel || enclosure\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eMounting Mode: panel-mounted\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/420e57dfad41a491a50d97c2f7bbac1d52d43486.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea8b9f5adb6069854bd3a295a4987961cb827524.pdf\" target=\"_blank\"\u003eBCPM_Solid Core Instruction Sheet - BCPM_Solid+Core+Quick_i0a2_+Z207197-0B_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846068363568,"sku":"BCPMB042S","price":5634.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/7704df5156365b38e19b0d53861883983adf7f71-large_66e732bf-3967-4fa0-add8-2cd9f7867c3b.png?v=1690382462"},{"product_id":"bcpmb084s-bcpm-power-monitoring-intermediate-84-solid-core-100-a-19-mm-ct","title":"BCPM power monitoring intermediate - 84 solid core 100 A - 19 mm CT spacing","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: voltage sag and swell detection\u003c\/li\u003e\n\u003cli\u003eVariant: intermediate\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: voltage || current || frequency || active power || power factor || active energy\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPM\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eConnection Pitch: 19 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: low-low current alarm || high-high current alarm || under voltage alarm || low current alarm || high current alarm || over voltage alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 84 x current transformer || 4 x cables\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 84 solid core CT 100 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 61036 || ANSI C12.1 || EN 61010 || UL 508\u003c\/li\u003e\n\u003cli\u003eMounting Support: enclosure || panel\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eMounting Mode: panel-mounted\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0d5239aa8f533c71ded8f04e4a65f232b7efaa87.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea8b9f5adb6069854bd3a295a4987961cb827524.pdf\" target=\"_blank\"\u003eBCPM_Solid Core Instruction Sheet - BCPM_Solid+Core+Quick_i0a2_+Z207197-0B_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846098903344,"sku":"BCPMB084S","price":8984.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/7704df5156365b38e19b0d53861883983adf7f71-large_fa4d5c61-1de0-461a-acef-9300e993c06b.png?v=1690382553"},{"product_id":"bcpmsca42s-bcpm-power-monitoring-advanced-42-split-core-ct-50-a","title":"BCPM power monitoring advanced - 42 split core CT 50 A","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: voltage sag and swell detection\u003c\/li\u003e\n\u003cli\u003eVariant: advanced\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: voltage || current || frequency || active power || power factor || active energy\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPMSC\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMSCA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: high current alarm || low current alarm || under voltage alarm || high-high current alarm || low-low current alarm || over voltage alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 42 x current transformer || 2 x cables || 2 x adapter board\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 42 split core CT 0.333 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eStandards: IEC 61036 || EN 61010 || ANSI C12.1 || UL 508\u003c\/li\u003e\n\u003cli\u003eMounting Support: board\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2ff9f1a4569d872dd6f8eaa068668a6fd1e67a43.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/35af3743e80be6a0b469d24740263fd3fb3b17b0.pdf\" target=\"_blank\"\u003eBCPM_Split Core Instruction Sheet - BCPM_Split+Core+Quick_i0a2_+Z207196-0A_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846130524464,"sku":"BCPMSCA42S","price":8580.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/40f691c6bcb95580ab88f335c8f8d020c5c334de-large.png?v=1690382680"},{"product_id":"a9mem3265-iem3265-energy-meter-ct-bacnet-1-digital-i-1-digital-o-multi","title":"iEM3265 energy meter - CT - BACnet - 1 digital I - 1 digital O - multi-tariff - MID","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: Acti9 iEM3000\u003c\/li\u003e\n\u003cli\u003eRange: Acti9\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: iEM3265\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: screw terminal block RS485\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 5...40 V DC@50 mA\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 32 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eStandards: BS EN 61557-12 || IEC 61557-12 || EN 61557-12 || BS EN 61326-1 || IEC 61326-1 || EN 61326-1 || BS EN 62052-11 || IEC 62052-11 || EN 62052-11 || BS EN 62053-21 || IEC 62053-21 || EN 62053-21 || BS EN 62052-22 || IEC 62053-22 || EN 62052-22 || BS EN 62052-23 || IEC 62053-23 || EN 62052-23 || BS EN 62052-31 || IEC 62052-31 || EN 62052-31 || BS EN 61010-1 || EN 61010-1 || IEC 61010-1 || UL 61010-1 || BS EN 61010-2-30 || IEC 61010-2-30 || EN 61010-2-30 || UL 61010-2-30 || BS EN 50470-3 || EN 50470-3 || BS EN 50470-1 || EN 50470-1 || ANSI C12.20\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 1 digital (static)\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003eMaximum Value Measured: 99999999 MWh\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: active and reactive energy || active and reactive power || current || voltage\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: BACnet 9.6, 19.2, 38.4, 57.6, 76.8 kbauds 4000 V\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010-1 safety) || CE EN 61557-12 power monitor) || CE EN\/IEC 61326-1 EMC) || UKCA BS EN 61010-1 safety) || UKCA BS EN 61557-12 power monitor) || UKCA BS EN 61326-1 EMC) || cULus UL 61010-1 safety) || cULus EN 61010-1 safety) || EAC EN 50470-3 sub-meter) || RCM EN 62052 sub-meter) || KZ EN 50470-3 sub-meter) || METAS EN 50470-1 sub-meter) || MID EN 50470-3 sub-meter) || MID EN 50470-1 sub-meter) || NMI NMI M 6-1\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 1 digital 0...5 V\/11...40 V 24 V DC\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 1-32767000 mA\u003c\/li\u003e\n\u003cli\u003eConnections - Terminals: current circuit screw terminals 6-6 mm² || voltage circuit screw terminals 2.5-2.5 mm²\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: tariff 4)\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: Green indicator light power ON || Yellow flashing LED accuracy checking || alarm overload\u003c\/li\u003e\n\u003cli\u003eTechnology Type: electronic\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P || 1P + N || 3P + N\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 5 A || 1 A\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: external CT 1 A or 5 A\u003c\/li\u003e\n\u003cli\u003eDisplay Type: LCD display\u003c\/li\u003e\n\u003cli\u003eOvervoltage Category: III\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing || partial meter || multi-tariff\u003c\/li\u003e\n\u003cli\u003eMetering Type: active, reactive, apparent energy (signed, four quadrant)\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.5S active energy IEC 62053-22 || class 0.5S active energy IEC 61557-12 || class C active energy EN 50470-3\u003c\/li\u003e\n\u003cli\u003eRated Voltage: 100-277 V || 173-480 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEnvironmental Disclosure: ENVPEP111276EN\u003c\/li\u003e\n\u003cli\u003eSustainable Offer Status: Green Premium product\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eCircularity Profile: ENVEOLI111261EN_V1\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 95 mm\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -25-55 °C - IEC\u003c\/li\u003e\n\u003cli\u003ePollution Degree: 2\u003c\/li\u003e\n\u003cli\u003e9 Mm Pitches: 10\u003c\/li\u003e\n\u003cli\u003eColor: White\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5-95 % 50-50 °C\u003c\/li\u003e\n\u003cli\u003eIp Degree Of Protection: front panel IP40 IEC 60529 || body IP20 IEC 60529\u003c\/li\u003e\n\u003cli\u003eWidth: 90 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 69 mm\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: \u0026lt; 6561.68 ft (2000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8bbd9ec495f65bd6033d60669fe8e269e51d7c7b.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ec6e512e9cf7405638b1974181735d504a765d2e.pdf\" target=\"_blank\"\u003eiEM31xx_iEM32xx_ PM32xx_series_ EAC Certificate - iEM3000+EAC (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/368bf7aa4cb7974df1abb17a5800501ffbd814d3.zip\" target=\"_blank\"\u003eiEM3000 series_METAS_Certificate_Reactive Energy_MID variants - CH-CH003-21022-01_IN-SE_iEM3zxy_+Metas+certificate (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e1aac6c4af4ea886054fbcf25bd509b2bd404f0e.zip\" target=\"_blank\"\u003eiEM3000 series_UL_Certificate of Compliance - UL_Certificate+of+compliance (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4bcddf2b44d89bc05a9cafa2758bd6b1b0bea94a.pdf\" target=\"_blank\"\u003eiEM3000 series_MID_Module B Certificate - SGS0099_R1+Schneider+Electric+iEM32xx+Iss1 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/37e9e1ac818f44f1a7d175c08864cb2ca38be712.zip\" target=\"_blank\"\u003eiEM3000 series_UL_CB Certificate - DK-117783-UL (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5945a611ee77f2bb3dccd2637eab2b017bef6772.pdf\" target=\"_blank\"\u003eiEM3000 series MID_Module D Certificate - iEM3000+series+MID_Module+D+Certificate (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/e31aeff979adb31385e8aa681621621f7894df7a.pdf\" target=\"_blank\"\u003eiEM3000 series_NMI_M 6-1 Certificate - 14-2-88_r4 (pdf)\u003c\/a\u003e\u003ch4\u003eCAD\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/861362468ecd7355930633ea7030886445fe460a.dwg\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-top (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/392af82bca8e9c009b35a447bf0246931443d166.stp\" target=\"_blank\"\u003eiEM3265_Energy Meter_3D CAD_Simplified File - A9MEM3265_3D-Simplified (stp)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38ab2d8804a08a2f84a42ddb37c63c648927c81a.dxf\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-top (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8b6c1a6cbca930008270216f7ee95dbc1c2b2514.dwg\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-right (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/9e61646ee6bc1fa27c35003dbb90c81938a4f183.dwg\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-bottom (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/46dd2c0315e9b97eb8b6d8287c8a0a1fb4f42be3.dxf\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-left (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7f58885731a9bc511106c9db00a26bac8b9f4432.dwg\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-left (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/40435c8dc78cbd384470929e20d65ae48ab5e9a4.dwg\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-front (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea0c0d79ba4b8af6e1dadbd5582c9f8e485c8f7a.dxf\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-isometric (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c4c7801caa5060f643b95e368ec9e2f4560fdd85.dwg\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-back (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fd2ba0c40470b3a357400d9bff0a2c45bf1b654b.dxf\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-bottom (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d78907a8073ace852abc4b595fa925fee21a8c40.dwg\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-isometric (dwg)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ff610c0467407ea54b6866e29e37e6320953fe97.dxf\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-back (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/923674c2074ff25dd3d35c0c5829a36d1d99049c.dxf\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-right (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a98dcb90740fff6e5f9f57b6c1148ed1d9f0fd17.dxf\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_2D-front (dxf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ab055927a0bd963a0d76c64cdcf6d317f13a7d53.stp\" target=\"_blank\"\u003eiEM3250_Energy Meter_3D CAD_Zip File - MCADDE0000095_3D-simplified-ec (stp)\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/01152f7ab0198d89946ee7e1b9886a7650a44a31.pdf\" target=\"_blank\"\u003eChanges to the 2020 National Electrical Code Brochure - 998-21037672_GMA-US_NEC+2020+eGuide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/245f3d4cdfb1353dd3d9cab2aa39dc0767807005.pdf\" target=\"_blank\"\u003ePower \u0026amp; Energy Management Solutions Overview - Brochure - Power+%26+Energy+Management+Solutions+Overview+Brochure+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/74f5e0d9fa41a76b5d4db8768ac354af4ec1df95.pdf\" target=\"_blank\"\u003eMulti-Meter Unit Enclosures for iEM3000 Energy Meters Brochure - Multiple+Meter+Unit+Enclosure+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a39fdbcc40bf1fd09b613423f3b750ee8a5d1a0d.pdf\" target=\"_blank\"\u003eiEM3000 series_RCM_Certificate - SDOC+iEM3000 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b1ee4adf33db7b218edba3d55eeb61b7a3ff8b9b.pdf\" target=\"_blank\"\u003eiEM3000 Range _EU Declaration of Conformity _MID versions - ECDiEM3000-MID-V9a.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b2c84399eb01531795ab9c59c0fa960f6f28374e.pdf\" target=\"_blank\"\u003eUKCA MIR_ Declaration of Conformity - UKMIRDOCiEM3000-A7-V3.docx (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea9971dd6fb1f5c5c20c4b65070cfe842c47901c.pdf\" target=\"_blank\"\u003eiEM3100 \/ iEM3200 \/ iEM3300 series_MID Sealing Instructions - Instruction sheet - NNZ7213200-00 (pdf)\u003c\/a\u003e\u003ch4\u003eUser guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c8e23486b0d423af2635cb6cce3a09e9aca82339.pdf\" target=\"_blank\"\u003eiEM3100 \/ iEM3200 \/ iEM3300 series- User Manual - DOCA0005EN-13 (pdf)\u003c\/a\u003e\u003ch4\u003eCircularity Profile\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7eb3dae2d1ccae3d32a25bc9def2aa17e7b890ea.pdf\" target=\"_blank\"\u003eActi 9 iEM3000 energy meter, Circularity Profile, End of Life Instructions - ENVEOLI111261EN_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eEnvironmental Disclosure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/987d8a66cde76fce5acb6d14b66ed58f94c00951.pdf\" target=\"_blank\"\u003eActi 9 iEM3000 energy meter, Environmental Disclosure, Product Environmental Profile - ENVPEP111276EN_V1 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/4431636f457955517103ae91731c091179e70f89.pdf\" target=\"_blank\"\u003eiEM3210 \/ iEM3215 \/ iEM3235 \/ iEM3255 \/ iEM3265 \/ iEM3275 - Instruction sheet - NHA15801-06 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846132818224,"sku":"A9MEM3265","price":749.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/9bfae96db70a5cc5273537cd6e83a8d330f6f436-large.png?v=1690382697"},{"product_id":"lvct00202s-lvct-200a-0-333-v-output-split-core-ct-31-mm-x-100-mm","title":"LVCT 200A - 0.333 V output - split core CT - 31 mm x 100 mm","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eProduct Destination: BCPM || BCPMSC || Enercept || iEM3000 || EM3500 || EM4200 || EM4900\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: cable 1.8 m AWG 18) 600 V\u003c\/li\u003e\n\u003cli\u003eAccessory \/ Separate Part Category: measurement accessory\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: current transformer\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 0.333 V\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 200 A\u003c\/li\u003e\n\u003cli\u003eCurrent Transformer Type: split core balance\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: LVCT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic BCPM) BCPMA multi-circuit energy meter || PowerLogic (PowerLogic BCPM) BCPMB multi-circuit energy meter || PowerLogic (PowerLogic BCPM) BCPME multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCA multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCB multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCE multi-circuit energy meter || PowerLogic (PowerLogic EM3500) EM3502 energy meter || PowerLogic (PowerLogic EM3500) EM3550 energy meter || PowerLogic (PowerLogic EM3500) EM3555 energy meter || PowerLogic (PowerLogic EM3500) EM3560 energy meter || PowerLogic (PowerLogic EM3500) EM3561 energy meter || PowerLogic (PowerLogic EM4200) EM4235 energy meter || PowerLogic (PowerLogic EM4200) EM4236 energy meter || PowerLogic (PowerLogic EM4900) EM4904 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4908 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4914 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4928 multi-circuit energy meter || Acti 9 (Acti9 iEM3000) iEM3455 energy meter || Acti 9 (Acti9 iEM3000) iEM3465 energy meter\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: 1 % 10...100 %\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eToxic Heavy Metal Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -15-60 °C\u003c\/li\u003e\n\u003cli\u003eNet Weight: 0.34 kg\u003c\/li\u003e\n\u003cli\u003eDepth: 30 mm\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 95-95 %\u003c\/li\u003e\n\u003cli\u003eWidth: internal 31 mm || external 121 mm\u003c\/li\u003e\n\u003cli\u003eHeight: internal 30 mm || external 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ebcf8ad31fec759f45cf34d68186df16b3a59920.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c2a250d86b97e6b7b89284c0a2a0e8c0016f1303.pdf\" target=\"_blank\"\u003eEnergy Meter Kit Handout - Energy+Meter+Kit+2pg+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38569afb3de012bba3b91e82f27f98030a8c34e8.pdf\" target=\"_blank\"\u003ePowerLogic™ Low Voltage Current Transducers - LVCT_Z205398-0H (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b6d79dedbb1081fffc4fdabab2bf436732a5e30b.DXF\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A.DXF\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7e7c2637e1a31bb207c243bce0a29f8985c13ad8.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_3D_0A (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b591658a315bc0d7d2e4a81c45a153ef9c857a7.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846151790896,"sku":"LVCT00202S","price":164.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/5cc31d1b63fa7f6fae7af79aab823c8076e160b5-large.png?v=1690382759"},{"product_id":"lvct00302s-lvct-300a-0-333-v-output-split-core-ct-31-mm-x-100-mm","title":"LVCT 300A - 0.333 V output - split core CT - 31 mm x 100 mm","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eProduct Destination: BCPM || BCPMSC || Enercept || iEM3000 || EM3500 || EM4200 || EM4900\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: cable 1.8 m AWG 18) 600 V\u003c\/li\u003e\n\u003cli\u003eAccessory \/ Separate Part Category: measurement accessory\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: current transformer\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 0.333 V\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 300 A\u003c\/li\u003e\n\u003cli\u003eCurrent Transformer Type: split core balance\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: LVCT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic BCPM) BCPMA multi-circuit energy meter || PowerLogic (PowerLogic BCPM) BCPMB multi-circuit energy meter || PowerLogic (PowerLogic BCPM) BCPME multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCA multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCB multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCE multi-circuit energy meter || PowerLogic (PowerLogic EM3500) EM3502 energy meter || PowerLogic (PowerLogic EM3500) EM3550 energy meter || PowerLogic (PowerLogic EM3500) EM3555 energy meter || PowerLogic (PowerLogic EM3500) EM3560 energy meter || PowerLogic (PowerLogic EM3500) EM3561 energy meter || PowerLogic (PowerLogic EM4200) EM4235 energy meter || PowerLogic (PowerLogic EM4200) EM4236 energy meter || PowerLogic (PowerLogic EM4900) EM4904 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4908 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4914 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4928 multi-circuit energy meter || Acti 9 (Acti9 iEM3000) iEM3455 energy meter || Acti 9 (Acti9 iEM3000) iEM3465 energy meter\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: 1 % 10...100 %\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eToxic Heavy Metal Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -15-60 °C\u003c\/li\u003e\n\u003cli\u003eNet Weight: 0.34 kg\u003c\/li\u003e\n\u003cli\u003eDepth: 30 mm\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 95-95 %\u003c\/li\u003e\n\u003cli\u003eWidth: internal 31 mm || external 121 mm\u003c\/li\u003e\n\u003cli\u003eHeight: internal 30 mm || external 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/acace81a63b42c9a3c4f6283ef88d52077d3cd3e.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c2a250d86b97e6b7b89284c0a2a0e8c0016f1303.pdf\" target=\"_blank\"\u003eEnergy Meter Kit Handout - Energy+Meter+Kit+2pg+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38569afb3de012bba3b91e82f27f98030a8c34e8.pdf\" target=\"_blank\"\u003ePowerLogic™ Low Voltage Current Transducers - LVCT_Z205398-0H (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b6d79dedbb1081fffc4fdabab2bf436732a5e30b.DXF\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A.DXF\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b591658a315bc0d7d2e4a81c45a153ef9c857a7.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7e7c2637e1a31bb207c243bce0a29f8985c13ad8.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_3D_0A (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846153855280,"sku":"LVCT00302S","price":164.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/5cc31d1b63fa7f6fae7af79aab823c8076e160b5-large_fef7490f-e57a-458d-be5b-eac2ceb919ef.png?v=1690382765"},{"product_id":"lvct00603s-lv-ct-600-a-0-333-v-output-split-core-ct-62-mm-x-132-mm","title":"LV CT 600 A - 0.333 V output - split core CT - 62 mm x 132 mm","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eProduct Destination: BCPM || BCPMSC || Enercept || iEM3000 || EM3500 || EM4200 || EM4900\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: cable 1.8 m AWG 18) 600 V\u003c\/li\u003e\n\u003cli\u003eAccessory \/ Separate Part Category: measurement accessory\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: current transformer\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eOutput Voltage: 0.333 V\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 600 A\u003c\/li\u003e\n\u003cli\u003eCurrent Transformer Type: split core balance\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: LVCT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRange Compatibility: PowerLogic (PowerLogic BCPM) BCPMA multi-circuit energy meter || PowerLogic (PowerLogic BCPM) BCPMB multi-circuit energy meter || PowerLogic (PowerLogic BCPM) BCPME multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCA multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCB multi-circuit energy meter || PowerLogic (PowerLogic BCPMSC) BCPMSCE multi-circuit energy meter || PowerLogic (PowerLogic EM3500) EM3502 energy meter || PowerLogic (PowerLogic EM3500) EM3550 energy meter || PowerLogic (PowerLogic EM3500) EM3555 energy meter || PowerLogic (PowerLogic EM3500) EM3560 energy meter || PowerLogic (PowerLogic EM3500) EM3561 energy meter || PowerLogic (PowerLogic EM4200) EM4235 energy meter || PowerLogic (PowerLogic EM4200) EM4236 energy meter || PowerLogic (PowerLogic EM4900) EM4904 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4908 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4914 multi-circuit energy meter || PowerLogic (PowerLogic EM4900) EM4928 multi-circuit energy meter || Acti 9 (Acti9 iEM3000) iEM3455 energy meter || Acti 9 (Acti9 iEM3000) iEM3465 energy meter\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: 1 % 10...100 %\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eToxic Heavy Metal Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Free of Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eReach Free Of Svhc: Yes\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -15-60 °C\u003c\/li\u003e\n\u003cli\u003eNet Weight: 0.58 kg\u003c\/li\u003e\n\u003cli\u003eDepth: 30 mm\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 95-95 %\u003c\/li\u003e\n\u003cli\u003eWidth: internal 62 mm || external 151 mm\u003c\/li\u003e\n\u003cli\u003eHeight: internal 73 mm || external 132 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/08168b5a603ca1068d5efcd8b0dd1fa2c2ae3ecb.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003ch4\u003eHandout\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/c2a250d86b97e6b7b89284c0a2a0e8c0016f1303.pdf\" target=\"_blank\"\u003eEnergy Meter Kit Handout - Energy+Meter+Kit+2pg+Handout+[digital+file] (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3e8008b89b502694e2a065635da6cea8fcba6648.pdf\" target=\"_blank\"\u003ePowerLogic Energy \u0026amp; Power Meters Catalogue for Panel Builders - PLSED310126EN_(web) (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/38569afb3de012bba3b91e82f27f98030a8c34e8.pdf\" target=\"_blank\"\u003ePowerLogic™ Low Voltage Current Transducers - LVCT_Z205398-0H (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7e7c2637e1a31bb207c243bce0a29f8985c13ad8.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_3D_0A (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/5b591658a315bc0d7d2e4a81c45a153ef9c857a7.pdf\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/b6d79dedbb1081fffc4fdabab2bf436732a5e30b.DXF\" target=\"_blank\"\u003eLVCT 100A or 200A or 300A Small Technical drawings - LVCTSCSm_2D_0A.DXF\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d5ab9b4ad42bec8e904f012764eaa8140edd9c35.pdf\" target=\"_blank\"\u003ePowerLogic EM4900 series Technical Datasheet - PLSED310134EN_(web) (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846166012208,"sku":"LVCT00603S","price":257.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/b4580a02fa271c1ec87142c9f07eb6168e59a3c8-large.png?v=1690382813"},{"product_id":"bcpma184s-bcpm-power-monitoring-advanced-84-solid-core-100-a-26-mm-ct","title":"BCPM power monitoring advanced - 84 solid core 100 A - 26 mm CT spacing","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 50 Hz || 60 Hz\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: voltage sag and swell detection\u003c\/li\u003e\n\u003cli\u003eVariant: advanced\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: voltage || current || frequency || active power || power factor || active energy\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPM\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMA\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eConnection Pitch: 26 mm\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 84 solid core CT 100 A\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: high current alarm || low current alarm || high-high current alarm || over voltage alarm || low-low current alarm || under voltage alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 84 x current transformer || 4 x cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eMounting Mode: panel-mounted\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eStandards: ANSI C12.1 || IEC 61036 || UL 508 || EN 61010\u003c\/li\u003e\n\u003cli\u003eMounting Support: panel || enclosure\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/1c95910f9f4e34737b012b1434b78647ad238604.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ea8b9f5adb6069854bd3a295a4987961cb827524.pdf\" target=\"_blank\"\u003eBCPM_Solid Core Instruction Sheet - BCPM_Solid+Core+Quick_i0a2_+Z207197-0B_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846166044976,"sku":"BCPMA184S","price":11161.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/7704df5156365b38e19b0d53861883983adf7f71-large_8dc04cfa-0d7a-4d21-b10f-62346d9fba4d.png?v=1690382815"},{"product_id":"metseem3560-powerlogic-em3500-din-rail-meter-bacnet-current-transformer","title":"PowerLogic EM3500 DIN rail meter - BACnet - current transformer","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Or Component Type: energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic EM3500\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: EM3560\u003c\/li\u003e\n\u003cli\u003eMetering Type: current I1, I2, I3, Iavg || voltage U21, U32, U13, V1, V2, V3 || peak demand power PM, QM, SM || demand power P, Q, S\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eCommunication Port Support: screw terminal block RS485\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 90...347 V AC 50\/60 Hz between phase and neutral UL || 156...600 V AC 50\/60 Hz between phases UL || 90...300 V AC 50\/60 Hz between phase and neutral CE || 125...300 V DC\u003c\/li\u003e\n\u003cli\u003eStandards: UL 508 || CSA C22.2 No 14-05 || IEC 61010-1\u003c\/li\u003e\n\u003cli\u003eNumber Of Outputs: 1 alarm output\u003c\/li\u003e\n\u003cli\u003eMounting Support: DIN rail\u003c\/li\u003e\n\u003cli\u003ePower Consumption In Va: 5-5 VA 347 V AC between phase and neutral) || 5-5 VA 600 V AC between phases)\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: CE IEC 61010 || cULus UL 508\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: active and reactive power total || active and reactive power per phase || apparent power total || apparent power per phase || power factor total || power factor per phase || peak demand power || current || voltage || frequency\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: BACnet MS\/TP 9600 bauds...115200 bauds (automatic detection) - 2-wire\u003c\/li\u003e\n\u003cli\u003eCommunication Service: total cumulated energy || total cumulated active energy\u003c\/li\u003e\n\u003cli\u003eRide-Through Time: 100 ms 120 V AC\u003c\/li\u003e\n\u003cli\u003eDisplay Digits: 5\u003c\/li\u003e\n\u003cli\u003eNumber Of Inputs: 1 pulse\u003c\/li\u003e\n\u003cli\u003eTamperproof Of Settings: protected by access code\u003c\/li\u003e\n\u003cli\u003eMeasurement Current: 5-32000 A\u003c\/li\u003e\n\u003cli\u003eInformation Displayed: status and alert || communication with system || input\/output status || error || Tx activity || Rx activity || instant power per usage\u003c\/li\u003e\n\u003cli\u003eFunction Available: fixed or rolling block || external synchronisation to communication\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on || by screws\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: Red LED threshold reached || Green flashing LED output signal\u003c\/li\u003e\n\u003cli\u003ePower Consumption In W: 3 W 300-300 V\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: power +\/- 0.2 % || energy +\/- 0.2 %\u003c\/li\u003e\n\u003cli\u003eTechnology Type: electronic\u003c\/li\u003e\n\u003cli\u003eBuffer Size: 32-bit 3\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P + N\u003c\/li\u003e\n\u003cli\u003eData Recording: energy consumption logs\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: split core current transducer 0.333 V or 1 V\u003c\/li\u003e\n\u003cli\u003eDisplay Type: Backlit LCD\u003c\/li\u003e\n\u003cli\u003eDevice Application: partial meter || sub billing\u003c\/li\u003e\n\u003cli\u003eAccuracy Class: class 0.2S power IEC 62053-22 || class 0.2S energy IEC 62053-22 || class 0.2S power ANSI C12.20 || class 0.2S energy ANSI C12.20\u003c\/li\u003e\n\u003cli\u003eRated Voltage: 90-347 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRohs Exemption Information: Yes\u003c\/li\u003e\n\u003cli\u003eMercury Free: Yes\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003cli\u003eWeee: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.\u003c\/li\u003e\n\u003cli\u003eChina Rohs Regulation: X\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAmbient Air Temperature For Operation: -30-70 °C\u003c\/li\u003e\n\u003cli\u003eHeight: 91 mm\u003c\/li\u003e\n\u003cli\u003e9 Mm Pitches: 12\u003c\/li\u003e\n\u003cli\u003eColor: dark grey\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-85 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 %\u003c\/li\u003e\n\u003cli\u003eWidth: 107 mm\u003c\/li\u003e\n\u003cli\u003eDepth: 59 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/864e58f31ee02b77163e6cb78023b63653b82dee.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eOther technical guide\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/bf0be01f351baa6f67348ae0f6d4d7ac6580c75e.pdf\" target=\"_blank\"\u003ePowerLogic EM3500 series Technical Datasheet - PLSED310037EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efa143c0c5263fb1977125b93a4b249b6a4b311.pdf\" target=\"_blank\"\u003eEM35xx Series Compact Power and Energy Meter Instruction Sheet - EM35xx_quick_Z206079-0F (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846191374640,"sku":"METSEEM3560","price":1306.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/23e83226e803e1b127ffbd24b675f8ad8cc22553-large_95edef7b-93aa-432a-9976-ad0875033a80.png?v=1690382899"},{"product_id":"bcpmscb60s-bcpm-power-monitoring-intermediate-60-split-core-ct-50-a","title":"BCPM power monitoring intermediate - 60 split core CT 50 A","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNetwork Frequency: 60 Hz || 50 Hz\u003c\/li\u003e\n\u003cli\u003eEnergy Management: sub billing and cost allocation\u003c\/li\u003e\n\u003cli\u003e[Us] Rated Supply Voltage: 90...277 V AC 50\/60 Hz +\/- 1 %\u003c\/li\u003e\n\u003cli\u003ePower Quality Analysis: voltage sag and swell detection\u003c\/li\u003e\n\u003cli\u003eVariant: intermediate\u003c\/li\u003e\n\u003cli\u003eType Of Measurement: voltage || current || frequency || active power || power factor || active energy\u003c\/li\u003e\n\u003cli\u003ePower Monitoring: basic instrumentation\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: multi-circuit energy meter\u003c\/li\u003e\n\u003cli\u003eProduct Name: PowerLogic BCPMSC\u003c\/li\u003e\n\u003cli\u003eDevice Application: sub billing\u003c\/li\u003e\n\u003cli\u003eDevice Short Name: BCPMSCB\u003c\/li\u003e\n\u003cli\u003eRange: PowerLogic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication Port Support: RS485\u003c\/li\u003e\n\u003cli\u003eMeasurement Accuracy: branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V\u003c\/li\u003e\n\u003cli\u003eMeasurement Voltage: 90-277 V phase to neutral || 150-480 V phase to phase\u003c\/li\u003e\n\u003cli\u003eSampling Rate: 256 samples\/cycle\u003c\/li\u003e\n\u003cli\u003eCommunication Port Protocol: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eUpdate Time: 1.8 s\u003c\/li\u003e\n\u003cli\u003eAnalogue Input Type: 60 split core CT 0.333 V\u003c\/li\u003e\n\u003cli\u003eCommunication Of Data: high current alarm || under voltage alarm || low current alarm || high-high current alarm || low-low current alarm || over voltage alarm\u003c\/li\u003e\n\u003cli\u003eProvided Equipment: 4 x cables || 4 x adapter board || 60 x current transformer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEu Rohs Directive: Compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHeight: 146 mm\u003c\/li\u003e\n\u003cli\u003eMounting Mode: clip-on\u003c\/li\u003e\n\u003cli\u003eAmbient Air Temperature For Storage: -40-70 °C\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 0-95 % 0-60 °C\u003c\/li\u003e\n\u003cli\u003eStandards: ANSI C12.1 || IEC 61036 || UL 508 || EN 61010\u003c\/li\u003e\n\u003cli\u003eMounting Support: board\u003c\/li\u003e\n\u003cli\u003eProduct Certifications: UL\u003c\/li\u003e\n\u003cli\u003eWidth: 288 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: 1.5 kg\u003c\/li\u003e\n\u003cli\u003eOperating Altitude: 9842.52 ft (3000 m)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/13587dba29496983bfec57b9880a49b587c0cd88.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eBrochure\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/2efe61bdf17114346c61e94f428216c95b933092.pdf\" target=\"_blank\"\u003ePower Quality Symptoms and Solutions Brochure - Power+Quality+Ebook (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d28728450bf69bf3eb545070ffc3b828d0139aa4.pdf\" target=\"_blank\"\u003eSquare D Energy Center Brochure - 998-21300163_GMA-US (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/59140c087b7422aaa126fe7a94ab9bc7dc9de4a1.pdf\" target=\"_blank\"\u003ePowerLogic Power Monitoring and Control Catalog - Web - PLSED309005EN_(web) (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/35af3743e80be6a0b469d24740263fd3fb3b17b0.pdf\" target=\"_blank\"\u003eBCPM_Split Core Instruction Sheet - BCPM_Split+Core+Quick_i0a2_+Z207196-0A_ML (pdf)\u003c\/a\u003e\u003ch4\u003eDeclaration of conformity\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/53ed83ed937d8cdef9d387fb857deb3f48a3bee1.pdf\" target=\"_blank\"\u003eUK Declaration of conformity - UK_DOC_BCPMxx_BCPMSCxx_A1-V2.docx (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d1f21e6d676d1d74b54e5866ffc67c591100ce69.pdf\" target=\"_blank\"\u003eEU Declaration of Conformity - ECDBCPMxx_BCPMSCxx-A1-V2.docx (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45846213820720,"sku":"BCPMSCB60S","price":9793.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/7704df5156365b38e19b0d53861883983adf7f71-large_6d99e9c0-9e15-4ac1-96f9-e6ed91fd4656.png?v=1690382997"}],"url":"https:\/\/soliselectricsupply.com\/collections\/power-metering-and-energy-monitoring-systems.oembed","provider":"Solis Electric Supply","version":"1.0","type":"link"}