{"title":"NEMA Two Speed Combination Starters","description":"","products":[{"product_id":"8810sbo4v02s-two-speed-starter-size-0-3-pole-melting-alloy-olr-open-120","title":"Two Speed Starter, Size 0, 3-Pole, Melting Alloy OLR, Open, 120\/110V 60\/50Hz","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: type S\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: starter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMotor Starter Type: 2 speed\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: without pilot light\u003c\/li\u003e\n\u003cli\u003eThermal Overload Type: melting alloy\u003c\/li\u003e\n\u003cli\u003eAuxiliary Contact Composition: without\u003c\/li\u003e\n\u003cli\u003eControl Type: Without\u003c\/li\u003e\n\u003cli\u003eNema Size: 0\u003c\/li\u003e\n\u003cli\u003eNumber Of Thermal Units Required: 6\u003c\/li\u003e\n\u003cli\u003eAsynchronous Motor Control Profile: constant\/variable torque\u003c\/li\u003e\n\u003cli\u003eMaximum Horse Power Rating: 3-3 hp 200 V AC, 3 phase || 3-3 hp 230 V AC, 3 phase || 5-5 hp 460\/575 V AC, 3 phase\u003c\/li\u003e\n\u003cli\u003e[Uc] Control Circuit Voltage: 120 V AC 60 Hz || 110 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eNema Degree Of Protection: not rated (open device)\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: lugs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 18 A\u003c\/li\u003e\n\u003cli\u003eControl Circuit: separate control circuit\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Not compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Certifications: UL listed file E78351 CCN NLDX || CSA LR60905 class 3211 04\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/05a2224a37f9d9f12d2d02af664914963e1fe433.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/961255bc9eb369d51f7e44e26304a9862bb7ab89.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, CSA - CSA+Certificate+60905++3211-04 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a1a9ac5cfb93fb07e22347c29c3ea82227e0832a.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, UL - NLDX.E78351 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a6b2cd95b7f13f5fe745b46419f6dd8c78676ce.pdf\" target=\"_blank\"\u003eFull Voltage Contactors and Starters Catalog - 8502CT9701 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/905db60934e388307818d118b4189b4cb8cad721.pdf\" target=\"_blank\"\u003e9999SM Mechanical Interlock Kits for Use with NEMA Size 00, 0, and 1 Reversing or Multi-Speed Contactors and Starters Installation Instructions - 9999-286 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/038abb762ce5ae3b2e685f83e9e1e2bb49ba1b26.pdf\" target=\"_blank\"\u003e8502SB and 8536SB AC Magnetic Contactors and Starters Installation Instructions - 30072-013-09 (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/997160852c8c01b1cd9c7693120f31a91532ded3.pdf\" target=\"_blank\"\u003eCurve: Melting Alloy Relay Design Thermal Unit Type BO.44-B45 AC Magnetic Starter Size 01 Type SB SC Series A With 3 Thermal Units Class 8536 Small Enclosure QMB I-Line - 30068-408 (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/5oM8IMwBJns\"\u003eReplacing Powerlogic PM800 Integrated Display with PM8D Display | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45840013754672,"sku":"8810SBO4V02S","price":2605.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/6ed587f056284ae578e361e1f40b3fba8c5f1d30-large.png?v=1690311932"},{"product_id":"8810sdo2v02s-two-speed-motor-starter-type-s-size-2-45a-25-hp-at-460vac-3","title":"Two speed motor starter, Type S, Size 2, 45A, 25 HP at 460VAC, 3 pole, melting alloy, 120VAC coil ,open","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: type S\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: starter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMotor Starter Type: 2 speed\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: without pilot light\u003c\/li\u003e\n\u003cli\u003eThermal Overload Type: melting alloy\u003c\/li\u003e\n\u003cli\u003eAuxiliary Contact Composition: without\u003c\/li\u003e\n\u003cli\u003eControl Type: Without\u003c\/li\u003e\n\u003cli\u003eNema Size: 2\u003c\/li\u003e\n\u003cli\u003eNumber Of Thermal Units Required: 6\u003c\/li\u003e\n\u003cli\u003eAsynchronous Motor Control Profile: constant\/variable torque\u003c\/li\u003e\n\u003cli\u003eMaximum Horse Power Rating: 15-15 hp 230 V AC, 3 phase || 25-25 hp 460\/575 V AC, 3 phase || 10-10 hp 200 V AC, 3 phase\u003c\/li\u003e\n\u003cli\u003e[Uc] Control Circuit Voltage: 120 V AC 60 Hz || 110 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eNema Degree Of Protection: not rated (open device)\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: lugs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 45 A\u003c\/li\u003e\n\u003cli\u003eControl Circuit: separate control circuit\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Not compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Certifications: UL listed file E78351 CCN NLDX || CSA LR60905 class 3211 04\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a9091c44bda5bacc56384e414eb00f751b8a9fa2.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/961255bc9eb369d51f7e44e26304a9862bb7ab89.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, CSA - CSA+Certificate+60905++3211-04 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a1a9ac5cfb93fb07e22347c29c3ea82227e0832a.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, UL - NLDX.E78351 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7d4738102694c6fc107b36bf9075ffc137f14df0.pdf\" target=\"_blank\"\u003eType SD AC Magnetic Contactors and Starters Installation Instructions - 30072-013-11 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a6b2cd95b7f13f5fe745b46419f6dd8c78676ce.pdf\" target=\"_blank\"\u003eFull Voltage Contactors and Starters Catalog - 8502CT9701 (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/bdd0d811c9d7d64d90416f91390bb48a85c4a7ec.pdf\" target=\"_blank\"\u003eCurve: Melting Alloy Relay Design Thermal Unit Type B4.85-B79 AC Magnetic Starter Size 2 Type SD Series A With 3 Thermal Units All Other larger Enclosures - 30068-410 (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/5oM8IMwBJns\"\u003eReplacing Powerlogic PM800 Integrated Display with PM8D Display | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45840110715184,"sku":"8810SDO2V02S","price":5570.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/58ca3b8d320cf6cc823d9e653eef0f5c4e938690-large.png?v=1690312593"},{"product_id":"8810sco3v02s-two-speed-starter-size-1-3-pole-melting-alloy-olr-open-120","title":"Two Speed Starter, Size 1, 3-Pole, Melting Alloy OLR, Open, 120\/110V 60\/50Hz","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: type S\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: starter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMotor Starter Type: 2 speed\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: without pilot light\u003c\/li\u003e\n\u003cli\u003eThermal Overload Type: melting alloy\u003c\/li\u003e\n\u003cli\u003eAuxiliary Contact Composition: without\u003c\/li\u003e\n\u003cli\u003eControl Type: Without\u003c\/li\u003e\n\u003cli\u003eNema Size: 1\u003c\/li\u003e\n\u003cli\u003eNumber Of Thermal Units Required: 6\u003c\/li\u003e\n\u003cli\u003eAsynchronous Motor Control Profile: constant horsepower\u003c\/li\u003e\n\u003cli\u003eMaximum Horse Power Rating: 5-5 hp 200 V AC, 3 phase || 5-5 hp 230 V AC, 3 phase || 7.5-7.5 hp 460\/575 V AC, 3 phase\u003c\/li\u003e\n\u003cli\u003e[Uc] Control Circuit Voltage: 110 V AC 50 Hz || 120 V AC 60 Hz\u003c\/li\u003e\n\u003cli\u003eNema Degree Of Protection: not rated (open device)\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: lugs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 27 A\u003c\/li\u003e\n\u003cli\u003eControl Circuit: separate control circuit\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Not compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Certifications: UL listed file E78351 CCN NLDX || CSA LR60905 class 3211 04\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/34764ee89f7e7b4690796363a1cee6aa0295140e.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a1a9ac5cfb93fb07e22347c29c3ea82227e0832a.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, UL - NLDX.E78351 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/961255bc9eb369d51f7e44e26304a9862bb7ab89.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, CSA - CSA+Certificate+60905++3211-04 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a6b2cd95b7f13f5fe745b46419f6dd8c78676ce.pdf\" target=\"_blank\"\u003eFull Voltage Contactors and Starters Catalog - 8502CT9701 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ef3fc2271cab8f7b94425e90747f8066c83e0f6.pdf\" target=\"_blank\"\u003e8502SC and 8536SC AC Magnetic Contactors and Starters Installation Instructions - 30072-013-10 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/905db60934e388307818d118b4189b4cb8cad721.pdf\" target=\"_blank\"\u003e9999SM Mechanical Interlock Kits for Use with NEMA Size 00, 0, and 1 Reversing or Multi-Speed Contactors and Starters Installation Instructions - 9999-286 (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/997160852c8c01b1cd9c7693120f31a91532ded3.pdf\" target=\"_blank\"\u003eCurve: Melting Alloy Relay Design Thermal Unit Type BO.44-B45 AC Magnetic Starter Size 01 Type SB SC Series A With 3 Thermal Units Class 8536 Small Enclosure QMB I-Line - 30068-408 (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/5oM8IMwBJns\"\u003eReplacing Powerlogic PM800 Integrated Display with PM8D Display | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45840227336496,"sku":"8810SCO3V02S","price":2319.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/6ed587f056284ae578e361e1f40b3fba8c5f1d30-large_a713c2ff-a49c-4dbc-8ad1-b458a47a32bd.png?v=1690313191"},{"product_id":"8810sco2v02s-two-speed-starter-size-1-3-pole-melting-alloy-olr-open-120","title":"Two Speed Starter, Size 1, 3-Pole, Melting Alloy OLR, Open, 120\/110V 60\/50Hz","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: type S\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: starter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMotor Starter Type: 2 speed\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: without pilot light\u003c\/li\u003e\n\u003cli\u003eThermal Overload Type: melting alloy\u003c\/li\u003e\n\u003cli\u003eAuxiliary Contact Composition: without\u003c\/li\u003e\n\u003cli\u003eControl Type: Without\u003c\/li\u003e\n\u003cli\u003eNema Size: 1\u003c\/li\u003e\n\u003cli\u003eNumber Of Thermal Units Required: 6\u003c\/li\u003e\n\u003cli\u003eAsynchronous Motor Control Profile: constant\/variable torque\u003c\/li\u003e\n\u003cli\u003eMaximum Horse Power Rating: 7.5-7.5 hp 200 V AC, 3 phase || 7.5-7.5 hp 230 V AC, 3 phase || 10-10 hp 460\/575 V AC, 3 phase\u003c\/li\u003e\n\u003cli\u003e[Uc] Control Circuit Voltage: 120 V AC 60 Hz || 110 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eNema Degree Of Protection: not rated (open device)\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: lugs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 27 A\u003c\/li\u003e\n\u003cli\u003eControl Circuit: separate control circuit\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Not compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Certifications: UL listed file E78351 CCN NLDX || CSA LR60905 class 3211 04\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ed98f5f3bce77bc682c94d5ab7d80886a57015fa.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a1a9ac5cfb93fb07e22347c29c3ea82227e0832a.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, UL - NLDX.E78351 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/961255bc9eb369d51f7e44e26304a9862bb7ab89.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, CSA - CSA+Certificate+60905++3211-04 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a6b2cd95b7f13f5fe745b46419f6dd8c78676ce.pdf\" target=\"_blank\"\u003eFull Voltage Contactors and Starters Catalog - 8502CT9701 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/905db60934e388307818d118b4189b4cb8cad721.pdf\" target=\"_blank\"\u003e9999SM Mechanical Interlock Kits for Use with NEMA Size 00, 0, and 1 Reversing or Multi-Speed Contactors and Starters Installation Instructions - 9999-286 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ef3fc2271cab8f7b94425e90747f8066c83e0f6.pdf\" target=\"_blank\"\u003e8502SC and 8536SC AC Magnetic Contactors and Starters Installation Instructions - 30072-013-10 (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/997160852c8c01b1cd9c7693120f31a91532ded3.pdf\" target=\"_blank\"\u003eCurve: Melting Alloy Relay Design Thermal Unit Type BO.44-B45 AC Magnetic Starter Size 01 Type SB SC Series A With 3 Thermal Units Class 8536 Small Enclosure QMB I-Line - 30068-408 (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/5oM8IMwBJns\"\u003eReplacing Powerlogic PM800 Integrated Display with PM8D Display | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843534840112,"sku":"8810SCO2V02S","price":3142.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/6ed587f056284ae578e361e1f40b3fba8c5f1d30-large_f441bf8c-3f51-4dbd-a53e-4e938eb8835b.png?v=1690367599"},{"product_id":"8810sco4v02s-two-speed-starter-size-1-3-pole-melting-alloy-olr-open-120","title":"Two Speed Starter, Size 1, 3-Pole, Melting Alloy OLR, Open, 120\/110V 60\/50Hz","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: type S\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: starter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMotor Starter Type: 2 speed\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: without pilot light\u003c\/li\u003e\n\u003cli\u003eThermal Overload Type: melting alloy\u003c\/li\u003e\n\u003cli\u003eAuxiliary Contact Composition: without\u003c\/li\u003e\n\u003cli\u003eControl Type: Without\u003c\/li\u003e\n\u003cli\u003eNema Size: 1\u003c\/li\u003e\n\u003cli\u003eNumber Of Thermal Units Required: 6\u003c\/li\u003e\n\u003cli\u003eAsynchronous Motor Control Profile: constant\/variable torque\u003c\/li\u003e\n\u003cli\u003eMaximum Horse Power Rating: 7.5-7.5 hp 230 V AC, 3 phase || 10-10 hp 460\/575 V AC, 3 phase || 7.5-7.5 hp 200 V AC, 3 phase\u003c\/li\u003e\n\u003cli\u003e[Uc] Control Circuit Voltage: 110 V AC 50 Hz || 120 V AC 60 Hz\u003c\/li\u003e\n\u003cli\u003eNema Degree Of Protection: not rated (open device)\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: lugs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 27 A\u003c\/li\u003e\n\u003cli\u003eControl Circuit: separate control circuit\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Not compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Certifications: UL listed file E78351 CCN NLDX || CSA LR60905 class 3211 04\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/df086086d7c8accce65566245f4d596736267272.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/961255bc9eb369d51f7e44e26304a9862bb7ab89.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, CSA - CSA+Certificate+60905++3211-04 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a1a9ac5cfb93fb07e22347c29c3ea82227e0832a.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, UL - NLDX.E78351 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a6b2cd95b7f13f5fe745b46419f6dd8c78676ce.pdf\" target=\"_blank\"\u003eFull Voltage Contactors and Starters Catalog - 8502CT9701 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/905db60934e388307818d118b4189b4cb8cad721.pdf\" target=\"_blank\"\u003e9999SM Mechanical Interlock Kits for Use with NEMA Size 00, 0, and 1 Reversing or Multi-Speed Contactors and Starters Installation Instructions - 9999-286 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ef3fc2271cab8f7b94425e90747f8066c83e0f6.pdf\" target=\"_blank\"\u003e8502SC and 8536SC AC Magnetic Contactors and Starters Installation Instructions - 30072-013-10 (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/997160852c8c01b1cd9c7693120f31a91532ded3.pdf\" target=\"_blank\"\u003eCurve: Melting Alloy Relay Design Thermal Unit Type BO.44-B45 AC Magnetic Starter Size 01 Type SB SC Series A With 3 Thermal Units Class 8536 Small Enclosure QMB I-Line - 30068-408 (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/5oM8IMwBJns\"\u003eReplacing Powerlogic PM800 Integrated Display with PM8D Display | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843547095344,"sku":"8810SCO4V02S","price":2319.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/6ed587f056284ae578e361e1f40b3fba8c5f1d30-large_edd92ee7-ff00-42b8-afd6-d9923b4a2de5.png?v=1690367886"},{"product_id":"8810seo12v02s-two-speed-starter-size-3-3-pole-melting-alloy-olr-open-120","title":"Two Speed Starter, Size 3, 3-Pole, Melting Alloy OLR, Open, 120\/110V 60\/50Hz","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: type S\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: starter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMotor Starter Type: 2 speed\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: without pilot light\u003c\/li\u003e\n\u003cli\u003eThermal Overload Type: melting alloy\u003c\/li\u003e\n\u003cli\u003eAuxiliary Contact Composition: without\u003c\/li\u003e\n\u003cli\u003eControl Type: Without\u003c\/li\u003e\n\u003cli\u003eNema Size: 3\u003c\/li\u003e\n\u003cli\u003eNumber Of Thermal Units Required: 6\u003c\/li\u003e\n\u003cli\u003eAsynchronous Motor Control Profile: constant\/variable torque\u003c\/li\u003e\n\u003cli\u003eMaximum Horse Power Rating: 30-30 hp 230 V AC, 3 phase || 25-25 hp 200 V AC, 3 phase || 50-50 hp 460\/575 V AC, 3 phase || 50-50 hp 380 V AC, 3 phase\u003c\/li\u003e\n\u003cli\u003e[Uc] Control Circuit Voltage: 110 V AC 50 Hz || 120 V AC 60 Hz\u003c\/li\u003e\n\u003cli\u003eNema Degree Of Protection: not rated (open device)\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: lugs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 90 A\u003c\/li\u003e\n\u003cli\u003eControl Circuit: separate control circuit\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Not compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Certifications: UL listed file E78351 CCN NLDX || CSA LR60905 class 3211 04\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/8edc2921657ca922fbe7b43b6cfc7d7562b305a5.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/961255bc9eb369d51f7e44e26304a9862bb7ab89.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, CSA - CSA+Certificate+60905++3211-04 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a1a9ac5cfb93fb07e22347c29c3ea82227e0832a.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, UL - NLDX.E78351 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a6b2cd95b7f13f5fe745b46419f6dd8c78676ce.pdf\" target=\"_blank\"\u003eFull Voltage Contactors and Starters Catalog - 8502CT9701 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/62920d708db179708136a1c43089e75707b86884.pdf\" target=\"_blank\"\u003e9999SM Mechanical Interlock Kits for Reversing or Multi-Speed, Size 3 or 4 Contactors and Starters - 318AS (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ce5f0ac656bd9d53ac2101cf1af9bd36b412a83e.pdf\" target=\"_blank\"\u003eClass 8502\/8536, Type SE AC Magnetic Contactors and Starters Installation Instructions - 30072-013-01 (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fc54726ee9d35e7b8de07179ff369d5ae8b6c7da.pdf\" target=\"_blank\"\u003eCurve: Melting Alloy Relay Design Thermal Unit Type CC20.9-CC180 AC Magnetic Starter Size 3 Type SE Series A With 3 Thermal Units All Other Larger Enclosures - 30068-300 (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/5oM8IMwBJns\"\u003eReplacing Powerlogic PM800 Integrated Display with PM8D Display | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45843639632176,"sku":"8810SEO12V02S","price":8390.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/aa90346893aeb0aaed3fa6ad8a3130784055855c-large_be6e24cb-b5a8-4f17-ab4a-cf92cfe7240f.png?v=1690373494"},{"product_id":"8810sfo2v02s-two-speed-starter-size-4-3-pole-melting-alloy-olr-open-120","title":"Two Speed Starter, Size 4, 3-Pole, Melting Alloy OLR, Open, 120\/110V 60\/50Hz","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: type S\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: starter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMotor Starter Type: 2 speed\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: without pilot light\u003c\/li\u003e\n\u003cli\u003eThermal Overload Type: melting alloy\u003c\/li\u003e\n\u003cli\u003eAuxiliary Contact Composition: without\u003c\/li\u003e\n\u003cli\u003eControl Type: Without\u003c\/li\u003e\n\u003cli\u003eNema Size: 4\u003c\/li\u003e\n\u003cli\u003eNumber Of Thermal Units Required: 6\u003c\/li\u003e\n\u003cli\u003eAsynchronous Motor Control Profile: constant\/variable torque\u003c\/li\u003e\n\u003cli\u003eMaximum Horse Power Rating: 40-40 hp 200 V AC, 3 phase || 50-50 hp 230 V AC, 3 phase || 100-100 hp 460\/575 V AC, 3 phase\u003c\/li\u003e\n\u003cli\u003e[Uc] Control Circuit Voltage: 120 V AC 60 Hz || 110 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eNema Degree Of Protection: not rated (open device)\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: lugs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 135 A\u003c\/li\u003e\n\u003cli\u003eControl Circuit: separate control circuit\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Not compliant\u003c\/li\u003e\n\u003cli\u003eReach Regulation: Reference contains Substances of Very High Concern above the threshold\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Certifications: UL listed file E78351 CCN NLDX || CSA LR60905 class 3211 04\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/aecbe2ca47156d44c755e0e462f5acf694746796.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/961255bc9eb369d51f7e44e26304a9862bb7ab89.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, CSA - CSA+Certificate+60905++3211-04 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a1a9ac5cfb93fb07e22347c29c3ea82227e0832a.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, UL - NLDX.E78351 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a6b2cd95b7f13f5fe745b46419f6dd8c78676ce.pdf\" target=\"_blank\"\u003eFull Voltage Contactors and Starters Catalog - 8502CT9701 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/12735317897f8d3a8e6ecb7aa42aba67658e1317.pdf\" target=\"_blank\"\u003e8502SF and 8536SF, AC Magnetic Contactors and Starters, Size 4, Series A, 2- and 3- Pole Installation Instructions - 30072-013-02 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/62920d708db179708136a1c43089e75707b86884.pdf\" target=\"_blank\"\u003e9999SM Mechanical Interlock Kits for Reversing or Multi-Speed, Size 3 or 4 Contactors and Starters - 318AS (pdf)\u003c\/a\u003e\u003ch4\u003eInformation label\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/d2e190eb9a6e0eb164c16a0c3376f25494c1cc8d.pdf\" target=\"_blank\"\u003eStickyback for NEMA 4 Starters, Class 8536, 8736 and 8810 Type S, with TeSys T Solid-State Overload Relay - 30072-453-56_tri (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/27e3c8b0f5f81b740c08a1c47c670eab9eddc6bb.pdf\" target=\"_blank\"\u003eCurve: Melting Alloy Relay Design Thermal Unit Type CC64.3-CC196 AC Magnetic Starter Size 4 Type SF Series A With 3 Thermal Units All Other larger Enclosures - 30068-303 (pdf)\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45844059095344,"sku":"8810SFO2V02S","price":21709.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/9b79262a6a6437855829ac7c0e2921c9d63270f0-large.png?v=1690374475"},{"product_id":"8810sco12v02s-two-speed-starter-size-1-3-pole-melting-alloy-olr-open-120","title":"Two Speed Starter, Size 1, 3-Pole, Melting Alloy OLR, Open, 120\/110V 60\/50Hz","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: type S\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: starter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMotor Starter Type: 2 speed\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: without pilot light\u003c\/li\u003e\n\u003cli\u003eThermal Overload Type: melting alloy\u003c\/li\u003e\n\u003cli\u003eAuxiliary Contact Composition: without\u003c\/li\u003e\n\u003cli\u003eControl Type: Without\u003c\/li\u003e\n\u003cli\u003eNema Size: 1\u003c\/li\u003e\n\u003cli\u003eNumber Of Thermal Units Required: 6\u003c\/li\u003e\n\u003cli\u003eAsynchronous Motor Control Profile: constant\/variable torque\u003c\/li\u003e\n\u003cli\u003eMaximum Horse Power Rating: 5-5 hp 200 V AC, 3 phase || 5-5 hp 230 V AC, 3 phase || 7.5-7.5 hp 460\/575 V AC, 3 phase\u003c\/li\u003e\n\u003cli\u003e[Uc] Control Circuit Voltage: 120 V AC 60 Hz || 110 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eNema Degree Of Protection: not rated (open device)\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: lugs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 27 A\u003c\/li\u003e\n\u003cli\u003eControl Circuit: separate control circuit\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Not compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Certifications: UL listed file E78351 CCN NLDX || CSA LR60905 class 3211 04\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ed69fe72697b29a4868be308005f1a6ca5dbe4c3.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a1a9ac5cfb93fb07e22347c29c3ea82227e0832a.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, UL - NLDX.E78351 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/961255bc9eb369d51f7e44e26304a9862bb7ab89.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, CSA - CSA+Certificate+60905++3211-04 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a6b2cd95b7f13f5fe745b46419f6dd8c78676ce.pdf\" target=\"_blank\"\u003eFull Voltage Contactors and Starters Catalog - 8502CT9701 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/7ef3fc2271cab8f7b94425e90747f8066c83e0f6.pdf\" target=\"_blank\"\u003e8502SC and 8536SC AC Magnetic Contactors and Starters Installation Instructions - 30072-013-10 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/905db60934e388307818d118b4189b4cb8cad721.pdf\" target=\"_blank\"\u003e9999SM Mechanical Interlock Kits for Use with NEMA Size 00, 0, and 1 Reversing or Multi-Speed Contactors and Starters Installation Instructions - 9999-286 (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/997160852c8c01b1cd9c7693120f31a91532ded3.pdf\" target=\"_blank\"\u003eCurve: Melting Alloy Relay Design Thermal Unit Type BO.44-B45 AC Magnetic Starter Size 01 Type SB SC Series A With 3 Thermal Units Class 8536 Small Enclosure QMB I-Line - 30068-408 (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/5oM8IMwBJns\"\u003eReplacing Powerlogic PM800 Integrated Display with PM8D Display | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":45844093174064,"sku":"8810SCO12V02S","price":4708.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/4f68103d77769f63faf6b80190c284c908818f76-large.png?v=1690374822"},{"product_id":"8810seo2v02s-two-speed-starter-size-3-3-pole-melting-alloy-olr-open-120","title":"Two Speed Starter, Size 3, 3-Pole, Melting Alloy OLR, Open, 120\/110V 60\/50Hz","description":"\u003cdiv id=\"dds\" class=\"dds-content\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRange Of Product: type S\u003c\/li\u003e\n\u003cli\u003eProduct Or Component Type: starter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eContractual warranty\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eWarranty: 18 months\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eComplementary\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMotor Starter Type: 2 speed\u003c\/li\u003e\n\u003cli\u003eLocal Signalling: without pilot light\u003c\/li\u003e\n\u003cli\u003eThermal Overload Type: melting alloy\u003c\/li\u003e\n\u003cli\u003eAuxiliary Contact Composition: without\u003c\/li\u003e\n\u003cli\u003eControl Type: Without\u003c\/li\u003e\n\u003cli\u003eNema Size: 3\u003c\/li\u003e\n\u003cli\u003eNumber Of Thermal Units Required: 6\u003c\/li\u003e\n\u003cli\u003eAsynchronous Motor Control Profile: constant\/variable torque\u003c\/li\u003e\n\u003cli\u003eMaximum Horse Power Rating: 30-30 hp 230 V AC, 3 phase || 25-25 hp 200 V AC, 3 phase || 50-50 hp 460\/575 V AC, 3 phase\u003c\/li\u003e\n\u003cli\u003e[Uc] Control Circuit Voltage: 120 V AC 60 Hz || 110 V AC 50 Hz\u003c\/li\u003e\n\u003cli\u003eNema Degree Of Protection: not rated (open device)\u003c\/li\u003e\n\u003cli\u003ePoles Description: 3P\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: lugs\u003c\/li\u003e\n\u003cli\u003eLine Rated Current: 90 A\u003c\/li\u003e\n\u003cli\u003eControl Circuit: separate control circuit\u003c\/li\u003e\n\u003cli\u003e[Ue] Rated Operational Voltage: 600 V AC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOffer Sustainability\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChina Rohs Regulation: Product out of China RoHS scope. Substance declaration for your information.\u003c\/li\u003e\n\u003cli\u003eEu Rohs Directive: Not compliant\u003c\/li\u003e\n\u003cli\u003eCalifornia Proposition 65: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironment\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProduct Certifications: UL listed file E78351 CCN NLDX || CSA LR60905 class 3211 04\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/0cb927ac5bc23b64f6b4c6236f8cc5c129c7db42.pdf\" target=\"_blank\"\u003eSpec Sheet\u003c\/a\u003e\u003ch4\u003eCertificate\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/961255bc9eb369d51f7e44e26304a9862bb7ab89.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, CSA - CSA+Certificate+60905++3211-04 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/a1a9ac5cfb93fb07e22347c29c3ea82227e0832a.pdf\" target=\"_blank\"\u003e8502S\/8702S, Certificate, UL - NLDX.E78351 (pdf)\u003c\/a\u003e\u003ch4\u003eCatalog\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/3a6b2cd95b7f13f5fe745b46419f6dd8c78676ce.pdf\" target=\"_blank\"\u003eFull Voltage Contactors and Starters Catalog - 8502CT9701 (pdf)\u003c\/a\u003e\u003ch4\u003eInstruction sheet\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/ce5f0ac656bd9d53ac2101cf1af9bd36b412a83e.pdf\" target=\"_blank\"\u003eClass 8502\/8536, Type SE AC Magnetic Contactors and Starters Installation Instructions - 30072-013-01 (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/62920d708db179708136a1c43089e75707b86884.pdf\" target=\"_blank\"\u003e9999SM Mechanical Interlock Kits for Reversing or Multi-Speed, Size 3 or 4 Contactors and Starters - 318AS (pdf)\u003c\/a\u003e\u003ch4\u003eTechnical Drawing\u003c\/h4\u003e\n\u003ca href=\"https:\/\/media.distributordatasolutions.com\/schneider_synd\/2023q2\/documents\/fc54726ee9d35e7b8de07179ff369d5ae8b6c7da.pdf\" target=\"_blank\"\u003eCurve: Melting Alloy Relay Design Thermal Unit Type CC20.9-CC180 AC Magnetic Starter Size 3 Type SE Series A With 3 Thermal Units All Other Larger Enclosures - 30068-300 (pdf)\u003c\/a\u003e\u003ch2\u003eVideos\u003c\/h2\u003e\n\u003cdiv\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/5oM8IMwBJns\"\u003eReplacing Powerlogic PM800 Integrated Display with PM8D Display | Schneider Electric Support\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46087039811888,"sku":"8810SEO2V02S","price":8390.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/1910\/4048\/products\/9b79262a6a6437855829ac7c0e2921c9d63270f0-large_8bd4d717-ec16-49ef-9779-d1b96131ad56.png?v=1691518457"}],"url":"https:\/\/soliselectricsupply.com\/collections\/nema-two-speed-combination-starters.oembed","provider":"Solis Electric Supply","version":"1.0","type":"link"}